• Title/Summary/Keyword: positive detector

Search Result 99, Processing Time 0.023 seconds

Oxygen Adsorption/Desorption Reaction of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al Capacitor (D.C. 전압 인가에 의한 Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al 캐패시터의 산소흡착/탈착 반응)

  • Lee, Jae-Hong;Lee, Joo-Hun;Kim, Chang-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1222-1225
    • /
    • 1997
  • A gaseous oxygen detector has been developed in a configuration of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al with highly resistive $SnO_x$ layer as the oxygen adsorptive element. In this paper, we present the characteristics of the device in response to oxygen adsoption/desorption under applied d.c. bias. Experimental results showed that the oxygen adsorptive response by the device was reduced significantly under a positive gate bias, for all experimental regions of $O_2$ partial pressure. On the other hand, the application of a negative gate bias increased the device's adsorptive response of oxgyen. A device model concerning this electroadsorption/desorption behavior of the device is provided.

  • PDF

Incidence and Level of Aflatoxins Contamination in Medicinal Plants in Korea

  • Lee, Sung Deuk;Yu, In Sil;Jung, Kweon;Kim, Yeon Sun
    • Mycobiology
    • /
    • v.42 no.4
    • /
    • pp.339-345
    • /
    • 2014
  • During 2011~2013, a total of 729 samples for 19 types of medicinal plant were collected from Seoulyekryungsi in Seoul, Korea, and investigated for the presence of aflatoxins. The samples were analyzed using immunoaffinity column cleanup and high-performance liquid chromatography coupled to a fluorescence detector after post-column derivatization. Aflatoxins were found in 124 out of the 729 analyzed samples: 65 containing aflatoxin B1 (AFB1), 24 with aflatoxin B2 (AFB2), 15 with aflatoxin G1 (AFG1), and 20 samples with aflatoxin G2 (AFG2). The ranges for positive samples were $0.1{\sim}404.7{\mu}g/kg$ for AFB1, $0.1{\sim}10.0{\mu}g/kg$ for AFB2, $0.1{\sim}635.3{\mu}g/kg$ for AFG1, $0.1{\sim}182.5{\mu}g/kg$ for AFG2, and $0.1{\sim}1,043.9{\mu}g/kg$ for total aflatoxins. Most of the medicinal plant samples (721, 98.9%) were below legal limits, but 8 samples exceeded the legal limits of 10 and $15{\mu}g/kg$ established by the Korean standard for AFB1 and total aflatoxins (the sum of AFB1, AFB2, AFG1 and AFG2), respectively.

Design of High Speed Analog Input Card for Ultrasonic Testing (초음파 탐상을 위한 고속 아날로그 입력 카드의 설계)

  • 이병수;이동원;박두석
    • Journal of the Korea Society of Computer and Information
    • /
    • v.5 no.4
    • /
    • pp.62-68
    • /
    • 2000
  • It was designed a high-speed analog input card that is a important device of ultrasonic testing flaw detector in the middle of non-destructive testing in this Paper. The A/D Board is inquired high-speed sampling rate and fast data acquisition system. This pater shows a design that has a function of Peak- Detection for ultrasonic testing by ISA Bus type and a 50MHz of A/D converter in order to do sampling more than quadruple frequency of transducer frequency.

  • PDF

Mornitoring of non-steroidal anti-inflammatory drugs in livestock products (축산식품 중 비스테로이드성 항염증 약물의 잔류함량 모니터링)

  • Choi, Yoon-Hwa;Kim, Yoen-Joo;Shin, Bang-Woo;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.3
    • /
    • pp.285-289
    • /
    • 2011
  • This study was conducted to determine the content of non-steroidal anti-inflammatory drugs (NSAIDs) in meats available on the Korean markets. The analysis was carried out using following conditions; C18 column ($100{\times}2.1$ mm, 1.7 ${\mu}m$), mobile phase composed of DW (containing 0.1% formic acid): acetonitrile (containing 0.1% formic acid), binary pump at a flow rate of 0.3 ml/min and 5 ${\mu}l$ of injection volume, MS/MS detector with ESI positive mode. The calibration range of five NSAIDs showed linearity ($r^2{\geq}0.99$) at concentration range of 3.125~200 ${\mu}g$/kg. The recoveries in fortified muscle more than 78.7~100.3%. The detection limits for meloxicam, ketoprofen, flunixin, carprofen and tolfenamic acid were 3.5, 1.6, 1.7, 9.8 and 4.8 ${\mu}g$/kg, respectively. We also monitored NSAIDs residue in cattle muscle 51 samples. The test results, NSAIDs were all not founded.

Distribution of Certain Chlorobenzenes in Seawater from Youngil Bay, Korea

  • Moon, Hyo-Bang;Park, Hee-Gu;Kim, Sang-Soo;Jeong, Seung-Ryul;Lee, Pil-Yong
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.107-111
    • /
    • 2001
  • Surface seawater was sampled from 20 stations in Youngil Bay, Korea in November 2000. The samples were analyzed for eight chlorobenzenes(CBs) out of a total of 12 in the congener series using a gas chromatography coupled to a mass spectrometer detector(GC/MSD). The total CB levels varied from 1.3 to 6.1 ng/L with a mean of 4.0 ng/L. Trichlorobenzene groups (sum of 1,3,5-, 1,2,4-, and 1,2,3-trichlorobenzene) were the predominant class among the four congener groups, while tetrachlorobenzenes(sum of 1,2,3,5-, 1,2,4,5-, and 1,2,3,4- tetrachlorobenzene) and pentachlorobenzene showed a low presence. The total CB levels exhibited similar patterns for all the stations. A significant positive correlation was observed between the individual CB compounds in the particulate samples, while the dissolved samples revealed a strong correlation between the heavier molecular weight CBs.

  • PDF

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

Conceptual Design and Technical Feasibility Analysis of an All-in-one Attachment Based Steel Pipe Pile Cutting Robot (굴삭기 기반 강관말뚝 두부정리 및 절단 부위 핸들링 로봇의 개념디자인 및 기술적 타당성 분석)

  • Yeom, Dong Jun;Han, Jae Hyun;Jung, Eui Hyun;Kim, Young Suk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.45-54
    • /
    • 2018
  • The primary objective of this study is to develop a conceptual design of all-in-one attachment based steel pipe pile cutting robot that improves the conventional work in safety, quality, convenience and productivity. For this, the following research works are conducted sequentially; 1)literature review, 2)field investigation, 3)selection of element technology for conceptual design, 4)deduction of conceptual design and its work process, 5)technical feasibility analysis of the conceptual design and its work process. As a result, leveling laser and laser detector, plasma cutter, rotary grapple are selected as core technologies. Futhermore, a conceptual design and work process of an all-in-one attachment based steel pipe pile cutting robot are developed based on the core technologies. According to the technical feasibility analysis result, at least 76.8% of the respondents are selected positive answer about each device of the all-in-one attachment based steel pipe cutting robot. It is expected that the application range and impact on the construction industry will be enormous due to the increasing trend of the steel pipe pile market.

Usefulness of Mobile Computed Tomography in Patients with Coronavirus Disease 2019 Pneumonia: A Case Series

  • Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.1018-1023
    • /
    • 2020
  • The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.

Design of NePID using Anomaly Traffic Analysis and Fuzzy Cognitive Maps (비정상 트래픽 분석과 퍼지인식도를 이용한 NePID 설계)

  • Kim, Hyeock-Jin;Ryu, Sang-Ryul;Lee, Se-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.811-817
    • /
    • 2009
  • The rapid growth of network based IT systems has resulted in continuous research of security issues. Probe intrusion detection is an area of increasing concerns in the internet community. Recently, a number of probe intrusion detection schemes have been proposed based on various technologies. However, the techniques, which have been applied in many systems, are useful only for the existing patterns of probe intrusion. They can not detect new patterns of probe intrusion. Therefore, it is necessary to develop a new Probe Intrusion Detection technology that can find new patterns of probe intrusion. In this paper, we proposed a new network based probe intrusion detector(NePID) using anomaly traffic analysis and fuzzy cognitive maps that can detect intrusion by the denial of services attack detection method utilizing the packet analyses. The probe intrusion detection using fuzzy cognitive maps capture and analyze the packet information to detect syn flooding attack. Using the result of the analysis of decision module, which adopts the fuzzy cognitive maps, the decision module measures the degree of risk of denial of service attack and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.094% and the max-average false negative rate of 2.936%. The true positive error rate of the NePID is similar to that of Bernhard's true positive error rate.

Simultaneous Multicomponent Analysis of Preservatives in Cosmetics by Gas Chromatography (GC를 이용한 화장품 살균·보존제의 다성분 동시분석법)

  • Cho, Sang Hun;Jung, Hong Rae;Kim, Young Sug;Kim, Yang Hee;Park, Eun Mi;Shin, Sang Woon;Eum, Kyoung Suk;Hong, Se Ra;Kang, Hyo Jeong;Yoon, Mi Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • Preservatives of cosmetics is managed by positive list in Korea. Positive list requires a proper quantitative analysis method, but the analysis method is still insufficient. In this study, gas chromatography with flame ionization detector was used to simultaneously analyze 14 preservatives in cosmetics. As a result of method validation, the specificity was confirmed by the calibration curves of 14 preservatives showing good linearity correlation coefficient of above 0.9997 except dehydroacetic acid (0.9891). The limits of detection (LOD) and quantification (LOQ) of 14 preservatives were 0.0001 mg/mL ~ 0.0039 mg/mL and 0.0003 mg/mL ~ 0.0118 mg/mL, respectively, but they were 0.0204 mg/mL, 0.0617 mg/mL for dehydroacetic acid, respectively. The precision (Repeatability) of the values was less than 1.0%, but 7.1% for dehydroacetic acid. The Accuracy (% recovery) of 14 preservatives in cosmetics showed 96.9% ~ 109.2%. Finally, this method was applied to 50 cosmetics available in market. Results showed that the commonly used preservatives were chlorophene, phenoxyethanol, benzyl alcohol and parabens. However, the amount of the detected preservatives was within maximum allowed limits established by KFDA.