• Title/Summary/Keyword: positions

Search Result 6,435, Processing Time 0.031 seconds

High-Resolution of Paleoenvironmental Reconstruction and Sea-Level History in Delaware Bay, the East Coast of U.S.A. (미국동부 델라웨어만의 고정밀도 해수면 역사와 고환경 복원)

  • YI, HI-IL;WEHMILLER, JOHN F.
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.320-331
    • /
    • 1995
  • The closely spaced cores were analyzed to find detailed reconstruction of paleoenvironments and sealable changes along the Delaware Bay coast. Three areas, Kitts Hummock Beach mars, the St. Jones River marsh, and Bowers marsh near the St. Jones River's mouth, were chosen because these areas are compose of their own geomorphic characteristics and sea-level history. since significance of the stratigraphic correlations was to determine sedimentary fancies and paleoenvironments, multidisciplinary methods such as lithological description, grain-size analysis, organic/inorganic content, water content, mineral composition, botanical analysis, micropaleontological analysis, and /SUP 14/C datings were performed. Five major divisions of marsh environments were recognized in the stratigraphic sections: freshwater marsh, initialfreshwater marsh, slightly brackish marsh, brackish marsh, and salt marsh. Most of the lower part in the stratigraphic sections show freshwater marsh. On the top of this, either brackish marsh or tidal flat/tidal stream was recorded. The pro-Holocene sediments consist of sand, mud, and sandy mud, The pre-Holocene configuration played an important role for developing the Holocene Paleoenvironmental changes. The irregular configuration of the pre-Holocene sediments consist of sand, mud, and sandy mud. The pre-Holocene configuration played an important role for developing the Holocene Paleoenvironmental changes. The irregular configuration of the pre-Holocene surface within short distances permitted the concurrent development of variable environments such as freshwater marsh, brackish marsh or salt marsh at similar elevations. The freshwater marsh in this case was formed in the areas of isolation, so saline-water cannot encroach upon these areas. This complex development of paleoenvironments leads to a difficulty in stratigraphic correlation and interpretation of local relative sea-level changes. The deposition of subsurface sediments was affected by sediment supply, compaction, fluvial activity, biological competition, local tectonics and isostacy, climate and local relative sea-level changes. It was interpreted that the positions in the changes from freshwater environments to brackish environments or ice versa are the turning points of transgressions and regressions. Therefore, multiple transgressions and regressions were identified in the stratigraphic sections of the study area.

  • PDF

Improvement of Selection Efficiency for Bacterial Blight Resistance Using SNP Marker in Rice (SNP 마커를 이용한 벼 흰잎마름병 저항성 선발 효율 증진)

  • Shin, Woon-Chul;Baek, So-Hyeon;Seo, Chun-Sun;Kang, Hyeon-Jung;Kim, Chung-Kon;Shin, Mun-Sik;Lee, Gang-Seob;Hahn, Jang-Ho;Kim, Hyun-Soon
    • Journal of Plant Biotechnology
    • /
    • v.33 no.4
    • /
    • pp.309-313
    • /
    • 2006
  • Discovery of single nucleotide polymorphisms (SNPs), including small insertions and deletions, is one of the hot topics in genetic research. The most common type of sequence variant consists of single base differences or small insertions and deletions at specific nucleotide positions. Significance of SNPs in rice is increasing for genetic research, positional cloning and molecular breeding. $F_2$ 170 lines and $F_3$ 194 lines derived from Sangjuchalbyeo/HR13721-53-3-1-3-3-2-2 Were used for Searching SNP markers related to bacterial blight resistance. Sangjuchalbyeo is susceptible to bacterial blight, but HR13721-53-3-1-3-3-2-2 has Xa1 gene resistant to bacterial blight. Individual lines were inoculated with $K_1$ race of bacterial blight and resistant or susceptible was evaluated after 3 weeks from inoculation. The genotypes of population were analysed by PCR-RFLP for SNP marker developing. The segregation of $F_2\;and\;F_3$ population showed almost 3:1, 1:1 ratio, respectively. Analysis of genotype using SNP marker is capable of confirming resistance for $K_1$ race and genotype through amplifying the gene using 16PFXal primer and digested the PCR product with Eco RV. There were close relation between resistance test for $K_1$ race and SNP marker genotype. Especially, DNA analysis using SNP marker is capable of judging homozygote/heterozygote in $F_2$ population compared with resistant test for Kl race. So, it seems to improve the selection efficiency in disease resistant breeding.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

Population-Based Newborn Hearing Impairment Screening Test Using GJB2 Mutation Analysis

  • Lee, Kyung-Ok;Jeong, Su-Jin;Byun, Ji-Young;Kim, Jeong-Sook;Lee, Hye-Jung;Seong, Hye-Soon;Kim, Kyung-Tae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.113-121
    • /
    • 2007
  • Hearing loss is a common congenital disorder that is frequently associated with mutations in the Cx26 gene (GJB2). Recently, the mutation analysis of GJB2 has been used in a newborn screening test for the detection of hearing impairment. Population-based studies should be performed before the application of genetic testing for the identification of deaf newborns. In this study, 8 positions of GJB2 mutations-including 35delG, 167delT, 235delC, V27I, V37I, M34T, E114G, and I203T-were analyzed using PCR-direct sequencing in a total of 437 healthy Korean neonates. DNAs from dried blood spots were extracted using a commercial DNA extraction kit. The PCR-amplified products (783 bps) of the GJB2 gene were detected using 2% agarose gel electrophoresis and subjected to direct sequencing. The sequences were compared with those in the GenBank database by using the BLAST program. In this study, 5 GJB2 mutations -including V27I (79G>A), V37I (109G>A), E114G (341A>G), I203T (608T>C), and 235delC- were found. Of the 437 neonate samples, 301 subjects showed GJB2 mutations (68.9%, 301/437). The V27I mutation was found in 271 subjects and was the most frequent (62.0%, 271/437). The E114G, I203T and V37I mutations were shown in 146, 17 and 14 subjects, respectively. The 235delC mutation was found in 1 subject. The E114G mutation was frequently accompanied by the V27I mutation. V27I/E114G (97.2%, 143/147) was the most common double mutation and 3 subjects had the double mutation V27I/I203T. A triple mutation, V27I/E114G/I203T, was found in 1 subject. In conclusion, PCR-direct sequencing is a convenient tool for the rapid detection of GJB2 mutations and this data might provide information for the genetic counseling of the GJB2 gene.

  • PDF

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

A Criteria on Nitrate Concentration in Soil Solution and Leaf Petiole Juice for Fertigation of Cucumber (Cucumis sativus L.) under Greenhouse Cultivation (시설 오이의 관비재배를 위한 토양용액과 엽병즙액중 질산태 농도 기준 설정)

  • Lim, Jae-Hyun;Lee, In-Bog;Kim, Hong-Lim
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2001
  • To develope a technique for efficiently managing fertilizer for cucumber, a quick test method to quantify nitrate content in soil solution and leaf petiole juice using a simple instrument was investigated. Among the nitrate analyzing instruments such as compact ion meter, nitrate ion meter, and test strip with reflectometer, the paper test-strip used in conjunction with a hand-held reflectometer was most closely correlated with ion chromatography method in nitrate content, and then it would be suggested with a tool that a farmer can use rapidly, conveniently and accurately for nitrate analysis in a field. Nitrate content in soil solution collected by porous cup was very variable on the lapsed time after drip irrigation and the sampling positions such as soil depth and the distance from dripper. As a result, a significant correlation between nitrate contents of soil solutions and 2M KCl soil extract was not found. However, nitrate content in soil solution extracted with a volume basis (soil:water=1:2) showed the highly significant correlation with that in 2M KCl extract. Nitrate contents of cucumber leaf petiole juices was greatly different between upper and lower leaves. Eleven to sixteen positioned-leaf would be a proper sampling position to determine nitrate content in leaf petiole for evaluating nutrient state by plant tissue analysis. From the secondary regression equations between nitrate contents of soil and petiole juice and the yield of cucumber, nitrate levels for real time diagnosis were estimated as $400mg\;l^{-1}$ soil solution by porous cup. $300mg\;l^{-1}$ in a soil volume extraction, and $1400mg\;l^{-1}$ in petiole juice from spring to summer season. In addition, the maximum yield of cucumber fruit in pot test was obtained in nitrate $1500mg\;l^{-1}$ level of petiole juice, which was similar to nitrate $1400mg\;l^{-1}$ in greenhouse trial.

  • PDF

Contralateral Breast Dose Reduction Using a Virtual Wedge (가상쐐기를 이용한 반대측 유방선량감소)

  • Yeo, In-Hwan;Kim, Dae-Yong;Kim, Tae-Hyun;Shin, Kyung-Hwan;Chie, Eui-Kyu;Park, Won;Lim, Do-Hoon;Huh, Seung-Jae;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.230-235
    • /
    • 2005
  • Purpose: To evaluate the contralateral breast dose using a virtual wedge compared with that using a Physical wedge and an open beam in a Siemens linear accelerator. Materials and Methods: The contralateral breast dose was measured using diodes placed on a humanoid phantom. Diodes were placed at 5.5 cm (position 1), 9.5 cm (position 2), and 14 cm (position 3) along the medial-lateral line from the medial edge of the treatment field. A 6-MV photon beam was used with tangential irradiation technique at 50 and 230 degrees of gantry angle. Asymmetrically collimated $17{\times}10cm$ field was used. for the first set of experiment, four treatment set-ups were used, which were an open medial beam with a 30-degree wedged lateral beam (physical and virtual wedges, respectively) and a 15-degree wedged medial beam with a 15-degree wedged lateral beam (physical and virtual wedges, respectively). The second set of experiment consists of setting with medial beam without wedge, a 15-degree wedge, and a 50-degree wedge (physical and virtual wedges, respectively). Identical monitor units were delivered. Each set of experiment was repeated for three times. Results: In the first set of experiment, the contralateral breast dose was the highest at the position 1 and decreased in order of the position 2 and 3. The contralateral breast dose was reduced with open beam on the medial side ($2.70{\pm}1.46%$) compared to medial beam with a wedge (both physical and virtual) ($3.25{\pm}1.59%$). The differences were larger with a physical wedge ($0.99{\pm}0.18%$) than a virtual wedge ($0.10{\pm}0.01%$) at all positions. The use of a virtual wedge reduced the contralateral breast dose by 0.12% to 1.20% of the proscribed dose compared to a physical wedge with same technique. In the second experiment, the contralateral breast dose decreased in order of the open beam, the virtual wedge, and the physical wedge at the position 1, and it decreased in order of a physical wedge, an open beam, and a virtual wedge at the position 2 and 3. Conclusion: The virtual wedge equipped in a Siemens linear accelerator was found to be useful in reducing dose to the contralateral breast. Our additional finding was that the surface dose distribution from the Siemens accelerator was different from a Varian accelerator.

Establishment of Valve Replacement Registry and Risk Factor Analysis Based on Database Application Program (데이터베이스 프로그램에 기반한 심장판막 치환수술 환자의 레지스트리 확립 및 위험인자 분석)

  • Kim, Kyung-Hwan;Lee, Jae-Ik;Lim, Cheong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.209-216
    • /
    • 2002
  • Background: Valvular heart disease is still the most common health problem in Korea. By the end of the year 1999, there has been 94,586 cases of open heart surgery since the first case in 1958. Among them, 36,247 cases were acquired heart diseases and 20,704 of those had valvular heart disease. But there was no database system and every surgeon and physician had great difficulties in analysing and utilizing those tremendous medical resources. Therefore, we developed a valve registry database program and utilize it for risk factor analysis and so on. Material and Method: Personal computer-based multiuser database program was created using Microsoft AccessTM. That consisted of relational database structure with fine-tuned compact field variables and server-client architecture. Simple graphic user interface showed easy-to-use accessability and comprehensibility. User-oriented modular structure enabled easier modification through native AccessTM functions. Infinite application of query function aided users to extract, summarize, analyse and report the study result promptly. Result: About three-thousand cases of valve replacement procedure were performed in our hospital from 1968 to 1999. Total number of prosthesis replaced was 3,700. The numbers of cases for mitral, aortic and tricuspid valve replacement were 1600, 584, 76, respectively. Among them, 700 patients received prosthesis in more than two positions. Bioprosthesis or mechanical prosthesis were used in 1,280 and 1,500 patients respectively Redo valve replacements were performed in 460 patients totally and 40 patients annually Conclusion: Database program for registry of valvular heart disease was successfully developed and used in personal computer-based multiuser environment. This revealed promising results and perspectives in database management and utilization system.

Synthesis of Cyclen-Based Copper Complexes as a Potential Estrogen Receptor Ligand (에스트로젠 수용체 리간드로서 사이클렌을 기본 구조로 한 구리 착물의 합성)

  • Park, Jeong-Chan;Pandya, Darpan N.;Jeon, Hak-Rim;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.326-334
    • /
    • 2007
  • Purpose: The estrogen receptor (ER), which is over-expressed in ER-positive breast tumors, has been imaged by positron emission tomography (PET) using $[^{18}F]$ labeled estrogen ligands, especially $[^{18}F]FES$. However, $[^{18}F]$ has relatively short-lived half-life ($t_{1/2}$ =1.8 h) and the labeling yield of radio-fluorination is usually low compared with $^{64}Cu\;(t_{1/2}=12.7\;h)$. 1,4,7,10-tetraazacyclododecane (cyclen) is used to form stable metal complexes with copper, indium, gallium, and gadolinium. With these in mind, we prepared cyclen-based Cu complexes which mimic estradiol in aspect of two hydroxyl groups. Materials and Methods: 1.7-Protected cyclen, 1.7-bis (benzyloxycarbonyl)-cyclen was synthesized according to the reported procedure. After introducing two 4-benzyloxybenzyl groups at 4,10-positions, the benzyloxycarbonyl and benzyl groups were removed at the same time by hydrogenation on Pd/C to give 1,7-bis(4-hydroxybenzyl)-1,4,7,10-tetraazacyclododecane (1). Results: The prepared ligand 1 was fully characterized by $^1H,\;^{13}C$ NMR, and mass spectrometer. The synthesized ligand was reacted with copper chloride and copper perchlorate to give copper complexes $[Cu(1)]^{2+}2(CIO_4^-)\;and\;[Cu(1)Cl]^+Cl^-$ which were confirmed by high-resolution mass (FAB). Conclusion: We successfully synthesized a cyclen derivative of which two phenol groups are located on trans position of N-atoms. And, two Cu(ll) complexes of +2 and +1 overall charge, were prepared as a potential PET tracers for ER imaging.