• Title/Summary/Keyword: positions

Search Result 6,435, Processing Time 0.032 seconds

The Effect of Vision and Proprioception on Lumbar Movement Accuracy (시각과 고유수용성 감각이 요부 운동의 정확도에 미치는 영향)

  • Sim, Hyun-Po;Yoon, Hong-Il;Youn, I-Na
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.31-44
    • /
    • 2007
  • The purposes of this study were to examine the normal lumbar proprioception and identify the effect of vision and proprioception on lumbar movement accuracy through measuring a reposition error in visual and non-visual conditions and to provide the basic data for use of vision when rehabilitation program is applied. The subjects of this study were 39 healthy university students who have average physical activity level. They were measured the ability to reproduce the target position(50% of maximal range of motion) of flexion, extension, dominant and non-dominant side flexion in visual and non-visual conditions. Movement accuracy was assessed by reposition error(differences between intended and actual positions) that is calculated by the average of absolute value of 3 repeated measures at each directions. The data were analysed by paired samples t-test, independent samples t-test, and repeated measures ANOVA. The results were as follows : 1. Movement accuracy of flexion, extension, dominant side flexion, and non-dominant side flexion was increased in visual condition. 2. There were no differences in the lumbar movement accuracy between sexes in visual and non-visual conditions. 3. In non-visual condition, the movement in coronal plane(dominant and non dominant side flexion) is more accurate than that in sagittal plane(flexion and extension). 4. In non-visual condition, there were no differences in the lumbar movement accuracy between dominant and non-dominant side flexion. In conclusion, this study demonstrates that the movement is more accurate when the visual information input is available than proprioception is only available. When proprioception is decreased by injury or disease, it disturbs the control of posture and movement. In this case, human controls the posture and movement by using visual compensation. However it is impossible to prevent an injury or trauma because most of injuries occur in an unexpected situation. For this reason, it is important to improve the proprioception. Therefore, proprioceptive training or exercise which improve the ability to control of posture and movement is performed an appropriate control of permission or interception of the visual information input to prevent an excessive visual compensation.

  • PDF

IL-6 gene promoter polymorph isms in Korean generalized aggressive periodontitis (한국인 전반적 급진성 치주염 환자에서 IL-6 유전자 다변성에 관한 연구)

  • Bang, Sun-Jung;Kim, Il-Shin;Kim, Ok-Su;Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.579-588
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the association of generalized aggressive periodontitis with IL-6 promoter gene single nucleotide polymorphisms(SNP). Material and Methods: The study population consisted of 52 generalized aggressive periodontitis patients(GAP) and 30 periodontally healthy control subjects, who were systemically healthy non-smokers. Genomic DNA was obtained from buccal swab. The IL-6 promotor SNP at the positions of -597, -572, and -174 were genotyped by amplifying the polymorphic region using polymerase chain reaction(PCR), restriction enzyme digestion and gel electrophoresis. Result: The genotype distributions for G/G, G/A and A/A genotypes of IL-6 -597 were 30.8%, 40.4%, and 28.8% in the GAP group and 53.3%, 40%, and 6.7% in the control group and were statistically different between 2 groups(p<0.05). Allele 2 frequency of IL-6 -597 were significantly higher in the GAP group than the control group(p<0.01). At the position of IL-6 -572, the distribution for C/C, C/G and G/G genotypes were 23.1%, 55.8% and 21.2% in the GAP group and 20%, 33.3%, and 46.7% in the control group. In female subjects, the genotype distribution were significantly different between 2 groups(p<0.01). In male subjects, allele 2 frequency of IL-6-572 was significantly lower in the GAP group than the control group(p<0.05). The genotype distribution of IL-6 -174 in the GAP group were 96.2%, 3.8% for G/G, G/C genotypes whereas only the G/G genotype was detected in the control group. Conclusion: In conclusion, significant associations were found in IL-6 gene promoter(-597, -572) polymorphisms and generalized aggressive periodontitis. Further cohort study will be necessary in larger population.

Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study

  • Gao, EnFeng;Hei, Wei-Hong;Park, Jong-Chul;Pang, KangMi;Kim, Sun Kyung;Kim, Bongju;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.5
    • /
    • pp.312-327
    • /
    • 2017
  • Purpose: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14-24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean $0.07{\pm}0.48mm$), while the crestal bone level decreased significantly, from $2.34{\pm}0.93mm$ at baseline to $1.70{\pm}1.10mm$ at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.

Assessment of Counting Efficiency of a Whole Body Counter by Human Body Size and Standing Position Using Monte Carlo Method (몬테카를로 방법론을 이용한 측정 대상의 인체 크기와 측정 위치에 따른 전신계수기 계수효율 평가)

  • Pak, Min Jung;Yoo, Jae Ryong;Ha, Wi-Ho;Lee, Seung-Sook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.46-53
    • /
    • 2014
  • For the case of radiation emergency, it is required to assess internal contamination of the public, including children as well as adults. The objective of the present study was to assess counting efficiency of a whole body counter by human body size and standing position of the measurement person. In this study, the FASTSCAN whole body counter used at National Radiation Emergency Medical Center of Korean Institute of Radiological and Medical Science was simulated by a radiation transport computer code. The simulation results of the counting efficiencies agreed well with measurements within the 2% of discrepancy for 4-year child and 5% for adults. The standing positions of the people were adjusted by body size to find the consistent trend of the counting efficiencies by human body size. Body size scaling factors of the whole body counter were derived to consider human body size and improve the measurement accuracy. The counting efficiency assessment methodology in this study can be successively used to improve the measurement accuracy when using a whole body counter for the case of radiation emergency.

Patterns of Middle School Students' Value-Judgement and Decision-Making on Biotechnology-Related Socioscientific Issues (생명공학과 관련된 사회적 쟁점에 대한 중학생들의 가치판단 및 의사결정 과정에서 드러난 가치 적용 방식 유형)

  • Ju, In-Ae;Lee, Hyunju
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.1
    • /
    • pp.79-93
    • /
    • 2013
  • This study examined value-judgement and decision-making process of middle school students on three biotechnology related socioscientific issues (SSI) (i.e. designer baby, amniotic fluid test, and embryonic stem cell research). In particular, it focused on the level of consistency in their value application to the decisions. Twenty 8th grade students participated in the SSI program. The participants were asked to mark their positions on each issue before and after the debates. All classroom and sub-group debates were audio-recorded. The researcher conducted individual interviews with 10 students after the program. The results show three patterns emerging. First, five students applied their personal values in a consistent manner when making decisions on the three consecutive issues. Second, three students demonstrated incremental resoluteness in their value application as the sessions proceeded and had tendency to be oriented towards a specific value, more so towards the end of the program than the beginning. And third, four students gradually showed ambivalence in their decisions as they participate in the program. The results suggest that science teachers addressing SSI need to encourage students to be aware of their own values and to engage in internalized decision-making in light of those values. They also need to be aware of the possible challenges that students might feel in their decision-making process caused by the complexity of SSI.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF

A comparative study on the user satisfaction between two different piezoelectric engines (두가지 피에조 엔진의 사용자 만족도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Choi, So-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.269-277
    • /
    • 2017
  • Purpose: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. Materials and Methods: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. Results: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below $41^{\circ}C$ after having been operated for 3 minutes. Conclusion: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.

The effect of restaurant's eco friendly inductions on the user's satisfaction and the repurchase intention (레스토랑의 친환경 기능성 인덕션이 이용자 만족과 재구매 의도에 미치는 영향)

  • Kwon, Myung-sook;Cho, Chun-bong
    • Journal of Venture Innovation
    • /
    • v.1 no.1
    • /
    • pp.197-210
    • /
    • 2018
  • The purpose of this study is to analyze the relationship between the induction servicescape and the user satisfaction and repurchase intention about the restaurant tables embedded with the most advanced eco - friendly induction range. The main results of this study are as follows. The demographic characteristics of the respondents were 104 male respondents and 106 female respondents, with male - female ratio almost similar. The respondents' positions and responsibilities consisted of 68 restaurant representatives and 142 restaurant managers or persons in charge. The number of restaurants embedded with the induction ranges staffing 5 or more employees was 62.4%, which clearly showed that they were larger than the average restaurants(2.8 employees). The result of hypothesis testing by regression analysis showed that the restaurant's eco - friendly functional induction servicescape had a significant effect on user satisfaction, and ② the eco - friendly functional induction servicescape of the restaurant had a significant influence on repurchase intention. ③ The operation of the restaurant with the induction of the eco - friendly function of the restaurant. The satisfaction of the manager has a significant influence on the repurchase intention. Therefor, the hypothesis suggested in this study was adopted.

A STUDY OF CONDYLAR POSITIONAL CHANCES BEFORE & AFTER STABILIZATION SPLINT THERAPY (교합안정장치 사용 전, 후의 하악과두 위치 변화에 관한 연구)

  • Lee, Suk-Kyung;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.113-122
    • /
    • 1998
  • Stabilization splint therapy Precedes orthodontic intervention to enable the operator to find a 'true' centric(which is stable and comfortable), to test the patient's response to a change in the occlusion, prior to embarking upon a complex course of occlusal therapy : and finally, to see if the centric relation position can be stabilized. For this study, 47 malocclusion Patients enrolled for orthodontic treatment at the Department of Orthodontics, College of Dentistry, Chosun University comprised the malocclusion group, little variation of growth factor by the second molar eruption. They had Cr-Co discrepancy beyond normal range. For each patients the stabilization splint with mutually protected type of occlusal scheme was applied for 3 months. Condylar positions in CR and CO were measured using Penadent articulators, Panadent condylar position indicator(CPI), and transcranial projection before & after stabilization splint therapy. On the basis of this study, the results of this study were as follows 1. In all samples using CPI, there were statistical significances in CR-CO discrepancy(p<0.001) both before 8t after stabilization splint therapy. 2. In Rt and Lt+Rt/2 of superior joint space using transcranial projection, there were statistical significances in CR-CO discrepancy({<0.05) before & after stabilization splint therapy. 3. In supero-inferior components using CPI, there were statistical significances in CR-CO discrepancy(p<0.01) before & after stabilization splint therapy. 4. In all components except Rt using transcranial projection, there were no statistical significances in CR-CO discrepancy(p>0.05) before & after stabilization splint therapy. To sum up, CPI might be more effective than transcranial projection to reveal the changes between CR-CO discrepancies and stabilization splint might be more useful appliance for displaying the vertical changes, than the antero-posterior changes, of condylar position.

  • PDF

Study on the Optimum Positions of Theodolite Station for Control Surveying (기준점측량(基準點測量)을 위한 데오돌라이트 관측점(觀測點)의 최적위치(最適位置)에 관한 연구(研究))

  • Yeu, Bock Mo;Lee, Jae Ki;Park, Hong Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.95-103
    • /
    • 1984
  • This paper is a study on improving the accuracy of control points by suggesting angular requirements which make geometric conditions to be optimum. For this purpose, a equation, by which the accuracy of control point coordinates measured in an arbitrary station can be estimated, is derived. This equation is integrated and average standard error of the coordinates is computed, so that the optimum location of observatory station is determined. In the case of triangulation, a regular triangle has been generally considered as the best geometric condition, but because the precision of each side is different, the $52.77^{\circ}$ isosceles triangle is founded to be the best one. Also in trigonometric leveling, the geometric condition is founded to be optimum when the base angle of a isosceles triangle is $45^{\circ}$. In control surveying for close-range photogrammetry the optimum relation between base length($B_0$) and object distance($D_0$) can be founded to be as follow; $D_0=0.357587-0.357967B_0+0.308555B_0{^2}$.

  • PDF