• Title/Summary/Keyword: portable device

Search Result 589, Processing Time 0.028 seconds

Development of portable game device with uncompressed HD video and high quality sound output (비압축 HD급 영상 및 고음질 음성 출력을 지원하는 휴대용 게임기 구현)

  • Lee, Chung-Hee;Lee, Jong-Hun;Jung, Woo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.391-393
    • /
    • 2006
  • In this paper, we develop a portable game device with uncompressed HD video and high quality sound output. Portable game devices support not only game function but also various complex functions recently. It especially supports TV-Out port to play realistic game, connecting a large screen display device. But the video and audio output signals of conventional TV-out port have the low performance and these signals are analog output. So, it is difficult that the users enjoy realistic game with benefit of high resolution digital TV. We propose the game device output with uncompressed digital signal, which has no delay of video/audio signal, also has strong immunity to external noise. Since it supports a high resolution video and high quality sound, users can playa realistic game. First, we implement the HDMI to the game device and we test reliability with the various resolutions video inputs and audio inputs. The proposed method can be applied multimedia devices requiring high performance output function as well as portable devices.

  • PDF

Development of Portable Wandering Device using Statistical Analysis (통계적 분석법을 활용한 도로용 원더링 장비개발)

  • Kim, Nak-seok;Park, Chang-woo;Park, Hyun-sik;Kim, Joo-yeol
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.1
    • /
    • pp.5-20
    • /
    • 2007
  • The role of a pavement means a social axis for the future as well as a function of road itself. To achieve its intended purposes, the maintenance technique of the pavement performance should be improved. For this, pavement investigators have dealt with the simulated pavement sites under actual environmental conditions. One of them is wandering device to improve the maintenance system of a pavement. The primary purpose of this research is to develop a portable wandering device using statistical analysis technique. It is noted that the new device using laser sensor demonstrates better field applications and reliability compare to the conventional one.

  • PDF

Design of a DC-DC Converter for Portable Device (휴대기기용 DC-DC 부스트 컨버터 집적회로설계)

  • Lee, Ja-kyeong;Song, Han-Jung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • In This Paper, A DC-DC Boost Converter for Portable Device has been Proposed. The Converter Which is Operated with 1 MHz High Switching Frequency is Capable of Reducing Mounting Area of Passive Devices Such as Inductor and Capacitor, Consequently is Suitable for Portable Device. This Boost Converter Consists of a Power Stage and a Control Block and a Protect Block. Proposed DC-DC Boost Converter has been Designed a 0.18 um Magnachip CMOS Process Technology, we Examined Performances of the Fabricated Chip and Compared its Measured Results with SPICE Simulation Data. Simulation Results Show that the Output Voltage is 4.8 V in 3.3 V Input Voltage, Output Current 95 mA Which is Larger than 20~50 mA.

Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen (이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Forensic Investigation of External USB Drive (외장형 USB 저장장치의 포렌식 조사방법)

  • Song, Yu-Jin;Lee, Jae-Yong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2010
  • Because of portable storage device's technical improvement, it's speeding up the conversion of mass storage. It means it's easier to move and save data. Generally, USB is using for portable storage device and forensic perspective, it's possible us to study data drain through portable storage device under securement of using vestige of USB. If we can secure using vestige of USB from boot domain it's possible to investigate data drain & prove criminal act. This thesis is suggesting Key/Thumb drive & USB Drive Enclosure's confirmation of using or not and division way though Disk Signature analysis.

Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users (휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발)

  • Jang, Kyung-Bae;Lee, Kyeong-Wan;Koo, Do-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

Recognition of Car License Plate Using Geometric Information from Portable Device Image (휴대단말기 영상에서의 기하학적 정보를 이용한 차량 번호판 인식)

  • Yeom, Hee-Jung;Eun, Sung-Jong;WhangBo, Taeg-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.10
    • /
    • pp.1-8
    • /
    • 2010
  • Recently, the character image processing technology using portable device camera image at home and abroad are actively conducted, but Practical use are lower rate because of accuracy and time-consuming process problems. In this paper, we propose the license plate recognition method based on geometric information from portable device camera image. In the extracted license plate region we recognize characters using the chain code and the Thickness information through the cumulative projected edge after performing the pre-processing work considering the angle difference, the contrast enhancement and the low resolution from portable device camera image. The proposed algorithm is effective and accurate recognition by light and reducing the processing time. And, the results from the character recognition success rate was 95%. In the future, we will research about license plate recognition algorithm using long distance image or added motion blur image.

Measuring the Degree of Content Immersion in a Non-experimental Environment Using a Portable EEG Device

  • Keum, Nam-Ho;Lee, Taek;Lee, Jung-Been;In, Hoh Peter
    • Journal of Information Processing Systems
    • /
    • v.14 no.4
    • /
    • pp.1049-1061
    • /
    • 2018
  • As mobile devices such as smartphones and tablet PCs become more popular, users are becoming accustomed to consuming a massive amount of multimedia content every day without time or space limitations. From the industry, the need for user satisfaction investigation has consequently emerged. Conventional methods to investigate user satisfaction usually employ user feedback surveys or interviews, which are considered manual, subjective, and inefficient. Therefore, the authors focus on a more objective method of investigating users' brainwaves to measure how much they enjoy their content. Particularly for multimedia content, it is natural that users will be immersed in the played content if they are satisfied with it. In this paper, the authors propose a method of using a portable and dry electroencephalogram (EEG) sensor device to overcome the limitations of the existing conventional methods and to further advance existing EEG-based studies. The proposed method uses a portable EEG sensor device that has a small, dry (i.e., not wet or adhesive), and simple sensor using a single channel, because the authors assume mobile device environments where users consider the features of portability and usability to be important. This paper presents how to measure attention, gauge and compute a score of user's content immersion level after addressing some technical details related to adopting the portable EEG sensor device. Lastly, via an experiment, the authors verified a meaningful correlation between the computed scores and the actual user satisfaction scores.

Study of DRM Application for the Portable Digital Audio Device (휴대용 디지털 오디오 기기에서의 DRM 적용에 관한 연구)

  • Cho, Nam-Kyu;Lee, Dong-Hwi;Lee, Dong-Chun;J. Kim, Kui-Nam;Park, Sang-Min
    • Convergence Security Journal
    • /
    • v.6 no.4
    • /
    • pp.21-27
    • /
    • 2006
  • With the introduction of sound source sharing over the high speed internet and portable digital audio, the digitalization of sound source has been rapidly expanded and the sales and distribution of sound sources of the former offline markets are stagnant. Also, the problem of infringement of copyright is being issued seriously through illegal reproduction and distribution of digitalized sound sources. To solve these problems, the DRM technology for protecting contents and copyrights in portable digital audio device began to be introduced. However, since the existing DRM was designed based on the fast processing CPU and network environment, there were many problems in directly applying to the devices with small screen resolution, low processing speed and network function such as digital portable audio devices which the contents are downloadable through the PC. In this study, the DRM structural model which maintains similar security level as PC environment in the limited hardware conditions such as portable digital audio devices is proposed and analyzed. The proposed model chose portable digital audio exclusive device as a target platform which showed much better result in the aspect of security and usability compared to the DRM structure of exiting portable digital audio device.

  • PDF

A Portable Skin Elasticity Measuring Device Based on Indentation Method Using Piezoelectric Effect (압전효과를 이용한 압인방식의 휴대용 피부탄력 측정장치)

  • Park, Jun-Young;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.9
    • /
    • pp.1307-1315
    • /
    • 2022
  • In this paper, we proposed and developed a new portable skin elasticity measuring device based on the indentation method using piezoelectric effect. The proposed device is designed to minimize the uncertainty caused by the layer structure of the skin when measuring the elasticity of the skin. And, we developed a piezoelectric-based thin-film pressure sensor that can measure quantitatively and quickly during repeated measurement as a device sensor. To confirm the effectiveness of the proposed measuring device, it was compared with the experimental results of the conventional measuring devices under the same experimental conditions, and statistical correlation analysis was performed between the experimental data of the proposed measuring device and the experimental data of the conventional measuring devices. As a result of the correlation analysis, it was confirmed that the proposed measuring device had a high correlation with the conventional measuring devices. Therefore, it was confirmed that the proposed skin elasticity measuring device was effective.