• Title/Summary/Keyword: polymer materials

Search Result 4,675, Processing Time 0.033 seconds

Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants

  • Szabo, Gyorgy;Barabas, Jozsef;Bogdan, Sandor;Nemeth, Zsolt;Sebok, Bela;Kiss, Gabor
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.34.1-34.14
    • /
    • 2015
  • Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years. Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants. Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

Surface Modification of TiO2 by Atmospheric Pressure Plasma (대기압 플라즈마를 이용한 TiO2 광촉매의 효율향상을 위한 표면 개질 연구)

  • Cho, S.J.;Jung, C.K.;Kim, S.S.;Boo, J.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.22-27
    • /
    • 2010
  • To improve surface wettability, each sample was treated by atmospheric pressure plasma (APP) using dielectric barrier discharge (DBD) system. Argon and oxygen gases were used for treatment gas to modify the $TiO_2$ surface by APP with RF power range from 50 to 200 W. Water contact angle was decreased from $20^{\circ}$ to $10^{\circ}$ with argon only. However, water contact angle was decreased from $20^{\circ}$ to < $1^{\circ}$ with mixture of argon and oxygen. Water contact angle with $O_2$ plasma was lower than water contact angle with Ar plasma at the same RF power. It seems to be increasing the polar force of $TiO_2$ surface. Also, analysis result of X-ray photoelectron spectra (XPS) shows the increase of intensity of O1s shoulder peak, resulting in increasing of surface wettability by APP. Moreover, each water contact angle increased according to increase past time. However, contact angle increase with plasma treatment was lower than without plasma treatment. Additionally, the efficiency of $TiO_2$ photocatalyst was improved by plasma surface-treatment through the degradation experiment of phenol.

Properties and Gas Permeability of PEBAX Composite Membrane Containing GO (GO를 함유한 PEBAX 복합막의 성질과 기체투과도)

  • Lee, Seul Ki;Hong, Se Ryeong;Lee, Hyun Kyung
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.233-242
    • /
    • 2018
  • To study gas membrane using GO (graphene oxide), the PEBAX [poly(ether-block-amide)]-GO polymer composite membrane was prepared by adding GO to PEBAX. Through this composite membrane, gas permeation characteristics for $H_2$, $N_2$, $CH_4$, and $CO_2$ were studied. As a result of the gas permeation test, the permeability of $N_2$, $CH_4$, and $CO_2$ to PEBAX-GO composite membranes gradually decreased as the GO content increased. On the other hand, the gas permeability of $H_2$ increased with the increase of GO content, and it was 21.43 barrer at the GO content of 30 wt%, which was about 5 times higher than that of PEBAX membrane. This is because the GO was easier to operate with a fast and selective gas transport channel for $H_2$ than other gases. The increased selectivity ($H_2/N_2$) and selectivity ($H_2/CH_4$) were influenced by the diffusion selectivity by the permeate gas size. The increased selectivity ($CO_2/N_2$) and selectivity ($CO_2/CH_4$) were more influenced by the solubility selectivity due to the affinity of $CO_2$ and GO for -COOH.

Isothermal Vapor-Liquid Equilibria at 333.15 K and Excess Molar Volumes and Refractive Indices at 303.15 K for the Mixtures of Propyl vinyl ether + Ethanol + Benzene (Propyl vinyl ether+Ethanol+Benzene 혼합계의 333.15 K에서의 등온 기액평형과 303.15 K에서의 과잉물성 및 굴절율편차)

  • Hwang, In-Chan;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.56-61
    • /
    • 2011
  • Alkyl vinyl ethers such as methyl vinyl ether, propyl vinyl ether, isopropyl vinyl ether, butyl vinyl ether and isobutyl vinyl ether are usually used as industrial solvents and chemical intermediates in the chemical or pharmaceutical industry. Recently, they are popularly used as raw materials for polymer electrolyte membrane fuel cells and as cellulose dyeing assistants. However, very few investigations about process design and operation data were reported for alkyl vinyl ether compounds and there are no data for propyl vinyl ether(PVE) systems as far as we know. In this work, the isothermal VLE data are reported at 333.15 K for the ternary systems of {PVE + ethanol + benzene} by using headspace gas chromatography(HSGC) and these VLE data were correlated using Wilson, NRTL and UNIQUAC equations. The excess volumes($V^E$) and deviations in molar refractivity(${\Delta}R$) data are also reported for the sub binary systems {PVE + ethanol}, {ethanol + benzene} and {PVE + benzene} at 303.15 K. These data were correlated with Redlich-Kister equation. In addition, isoclines of $V^E$ and DR for ternary system {PVE + ethanol + benzene} were also calculated from Radojkovi equation.

In Vitro Study Evaluating the Antimicrobial Activity of Vancomycin-Impregnated Cement Stored at Room Temperature in Methicillin-Resistant Staphylococcus aureus (상온에서 보관한 반코마이신 함유 항생제 시멘트의 메티실린 내성 포도상구균에 대한 항균력 조사)

  • Park, Se-Jin;Cho, Yongun;Lee, Seok Won;Woo, Hee-Yeon;Lim, Sang Eun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.1
    • /
    • pp.38-43
    • /
    • 2018
  • Purpose: Treatment of diabetic foot infection due to methicillin-resistant Staphylococcus aureus (MRSA) remains challenging. Applying vancomycin-impregnated cement is one of the best methods of treatment. Vancomycin-impregnated cement has been used worldwide; however, to date, there is a limited number of studies regarding its use. We evaluated the duration of antimicrobial activity of vancomycin-impregnated cement stored at room temperature after manufacturing. Materials and Methods: The vancomycin-impregnated cement was manufactured by mixing 1 g of vancomycin with 40 g of polymer and adding 17.90 g of liquid monomer. The cement dough was shaped into flat cylinders with diameter and height of 6 mm and 2 mm, respectively. Another cement of the same shape without mixing vancomycin was prepared as the negative control. All manufactured cements were sterilized with ethylene oxide gas and stored at room temperature. Each cement was placed on Mueller Hinton agar plate lawned with standard MRSA strain. Standard vancomycin disk and gentamicin disk were placed together. After 24 hours, the diameter of inhibition zone was measured, and if the diameter was less than 15 mm, vancomycin-impregnated cement was regarded as a loss of antimicrobial activity. The study was repeated every 2 weeks until vancomycin-impregnated cements lost their antimicrobial activity. Results: Vancomycin-impregnated cement stored for a duration of 16 weeks created a 14 mm inhibition zone, while vancomycin disk created a 15 mm inhibition zone. Vancomycin-impregnated cement stored for a duration of 17 weeks created 7 mm and 9 mm inhibition zones, while vancomycin disk created 16 mm and 15 mm inhibition zones, respectively. Conclusion: We found a decrease of antimicrobial activity in vancomycin-impregnated cements after 16 weeks. After 17 weeks, they showed definite loss of antimicrobial activity. Therefore, we recommend not using vancomycin-impregnated cement spacers that has been stored for more than 16 weeks at room temperature.

Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion (혐기성 소화의 후처리로서 분리막의 여과특성 연구)

  • Choo, Kwang-Ho;Lee, Chung-Hak;Pek, Un-Hwa;Koh, Ui-Chan;Kim, Sang-Won;Koh, Jong-Ho
    • Applied Chemistry for Engineering
    • /
    • v.3 no.4
    • /
    • pp.730-738
    • /
    • 1992
  • Filtration characteristics according to membrane materials were studied In the ultrafiltration of anaerobic digestion broth as a post treatment method. A series of resistances for different membranes were quantitatively assessed on the basis of the resistance-in-series model. Flux behavior observed with the digestion broth was irrelevant to initial water permeabilities of each membrane. The fluoro polymer membrane showed the most significant improvement of flux with increase of cross-flow velocity, which suggests that the cake layer formed on this membrane is more weakly attached to the membrane surface than those on the other membranes. Flux reduction during longtime running was attrib-used to the polarization layer resistance ($R_p$) as well as the fouling layer resistance($R_f$). Continuous increase of $R_p$ may reflect the variation in the characteristics of cake layers, which could result from size, shape, and structure changes due to lysis and growth of biomass. Hydrophilic cellulosic membrane had a much lower fouling tendency than hydrophobic polysulfone membrane. The depressurization method induced a small increase in flux of $5-10L/m^2/h$. During washing and cleaning, filtrability of each membrane was rapidly recovered within 15 minutes until a stationary value was reached.

  • PDF

Preparation of Bio-Chemical Sensor Electrodes by Using Electrical Impedance Properties of Carbon Nanotube Based Bulk Materials (탄소나노튜브 기반 벌크 소재의 전기적 임피던스 특성을 이용한 생화학 센서용 전극 개발 연구)

  • So, Dae-Sup;Huh, Hoon;Kim, Hee-Jin;Lee, Hai-Won;Kang, In-Pil
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.495-499
    • /
    • 2010
  • To develop chemical and biosensors, this paper studies sensing characteristics of bulk carbon nanotube (CNT) electrodes by means of their electrical impedance properties due to their large surface area and excellence chemical absorptivity. The sensors were fabricated in the form of film and nano web style by using composite process for mass production. The bulk composite electrodes were fabricated with singlewall and multi-wall carbon nanotubes based on host polymers such as Nafion and PAN, using a solution-casting and an electrospinning technique. The resistance and the capacitance of electrodes were measured with LCR meter under the various amounts of buffer solution to study the electrical impedance change properties of them. On the experimental of sensor electrode, impedance characteristics of the composite electrode are affected by its host polymer and nanofiller and its sensing response showed saturated result after applying some amounts of buffer solution for test chemical. Especially, the capacitance values showed drastic changes while the resistance values only changed within few percent range. It is deduced that the ions in the solution penetrated and diffused into the electrodes surface changed the electrical properties of the electrodes much like a doping effect.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Structural Properties of Cold Water Extractable ${\alpha}-D-glucan$ in Rice Flours (쌀가루 냉수추출 ${\alpha}-D-glucan$의 분자구조적 특성)

  • Park, Yong-Kon;Seog, Ho-Moon;Nam, Young-Jung;Choi, Kwang-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.603-610
    • /
    • 1990
  • The structural properties of cold water extractable ${\alpha}-D-glucan$ in rice flours obtained by various milling methods were investigated. The blue value, ${\lambda}_{max}$ values of the iodine complex and ${\beta}-amylolysis$ limit of the cold water extractable ${\alpha}-D-glucan$ were in the range of $0.026{\sim}0.030,\;518{\sim}522\;nm$ and $52.7{\sim}59.6%$, respectively, indicating these materials were composed mainly of amylopectin-like polymer. The gel chromatography on Sepharose CL-2B indicated that the cold water extractable ${\alpha}-D-glucan$ had lower molecular weight but wider molecular weight distribution than that of the original rice amylopectin. The Sephadex G-50 gel chromatography showed that the unit chain distribution of cold water extratable ${\alpha}-D-glucan$ after debranching with pullulanase was similar to that of rice amylopectin. And the ion chromatography of the distribution pattern of the chain length below D.P.30 in the debranched ${\alpha}-D-glucan$ indicated only blade-milled flour was similar to the amylopectin, but in the amount of unit chain below D.P.10, all the ${\alpha}-D-glucan$ in rice flours was higher than that of amylopectin.

  • PDF

Physicochemical Properties of Various Milled Rice Flours (제분방법별 쌀가루의 이화학적 특성)

  • Park, Yong-Kon;Seog, Ho-Moon;Nam, Young-Jung;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.504-510
    • /
    • 1988
  • The physicochemical properties of rice flours which were obtained by dry milling(blade, hammer, test and micro mill) and wet & dry milling (roller & micro mill) were investigated. The resulting flour particle sizes were reduced in the order that of blade, hammer, test, micro and roller & micro mill. Scanning electron microscopic examination showed that the starch granules were freed from the imbedding matrix as the particles became finer. The test-milled flour had the hightest levels of starch damage, maltose value and hot-water soluble amylose content, and the blade-milled flour showed the lowest levels. Amylograph viscosity and gelatinization temperature of the flours decreased as the particles became finer, and the addition of $Hg^{+2}$ increased the peak viscosity of the dry-milled flour pastes, whereas the wet & dry-milled flour did not show any changes. The blue values and ${\lambda}$max values of the iodine complex of the cold-water extractable ${\alpha}-D-glucan$ from flours were in the range of 0.023-0.029 and 518-522nm, respectively, indicating these materials were shown to be mainly composed of amylopectin-like polymer.

  • PDF