• Title/Summary/Keyword: pollutant source

Search Result 638, Processing Time 0.026 seconds

Pollutant Load Characterization with Flow Conditions in Heukcheon Stream (흑천의 유량조건별 오염부하량 특성)

  • Choi, Kyungwan;Lee, Sangwon;Noh, Changwan;Lee, Jaekwan;Lee, Youngjoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.551-557
    • /
    • 2015
  • The TMDL (Total Maximum Daily Load) has been used to determine the water quality target. LDC (Load Duration Curve) based on hydrology has been used to support water quality assessments and development of TMDL. Also FDC (Flow Duration Curve) analysis can be used as a general indicator of hydrologic condition. The LDC is developed by multiplying FDC with the numeric water quality target of the factor for the pollutant of concern. Therefore, this study was to create LDC using the stream flow data and numeric water quality target of BOD and T-P in order to evaluate the pollutant load characterization by flow conditions in Heukcheon stream. When it is to be a high-flows condition, BOD and T-P are necessary to manage. BOD and T-P did not satisfy the numeric water quality target for both seasons (spring and summer). In order to meet the numeric water quality target in Heukcheon stream, management of non point source pollutant is much more important than that of point source pollutant control.

Installation and operation of automatic nonpoint pollutant source measurement system for cost-effective monitoring

  • Jeon, Jechan;Choi, Hyeseon;Shin, Dongseok;Kim, Lee-hyung
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.99-104
    • /
    • 2019
  • In Korea, nonpoint pollutants have a significant effect on rivers' water quality, and they are discharged in very different ways depending on rainfall events. Therefore, preparing an optimal countermeasure against nonpoint pollutants requires much monitoring. The present study was conducted to help prepare a method for installing an automatic nonpoint pollutant measurement system for the cost-effective monitoring of the effect of nonpoint pollutants on rivers. In the present study, monitoring was performed at six sites of a river passing through an urban area with a basin area of $454.3km^2$. The results showed that monitoring could be performed for a relatively long time interval in the upstream and downstream regions, which are mainly comprised of forests, regardless of the rainfall amount. On the contrary, in the urban region, the monitoring had to be performed at a relatively short time interval each time when the rainfall intensity changed. This was because the flow rate was significantly dependent on the rainfall's intensity. The appropriate sites for installing an automatic measurement system were found to be a site before entering the urban region, a site after passing through the urban region, and the end of a river where the effects of nonpoint pollutant sources can be well-decided. The analysis also showed that the monitoring time should be longer for the rainfall events of a higher rainfall class and for the sites closer to the river end. This is because the rainfall runoff has a longer effect on the river. However, the effect of nonpoint pollutant sources was not significantly different between the upstream and the downstream in the cases of rainfall events over 100 mm.

Estimation of Pollutants Loading from Non-Point Sources Based on Rainfall Event and Land use Characteristics (강우강도와 토지이용을 고려한 비점오염물질 부하량 산정에 관한 연구)

  • Lee, Hye-Won;Choi, Nam-Hee;Lee, Yong-Seok;Choi, Jung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.572-577
    • /
    • 2011
  • The unit load has simply been used to estimate total pollutant loading from non-point sources, however, it does not count on the variable pollutant loading according to land use characteristics and rainfall intensity. Since pollutant emission from the watershed is strongly dependent on the rainfall intensity, it is necessary to find out the relationship between pollutant loading and rainfall intensity. The objective of this study is to develop simple and easy method to compute non-point source pollution loads with consideration of rainfall intensity. Two non-point source removal facility at Gyeongan-dong (Gwangju-si) and Mohyeon-myeon (Yongin-si), Gyeonggi-do was selected to monitor total rainfall, rainfall intensity, runoff characteristics and water quality from June to November, 2010. Most of Event Mean Concentrations (EMC) of measured water quality data were higher in Gyeongan which has urban land use than in Mohyeon which has rural land use. For the case of TP (Total Phosphorus), Mohyeon has higher values by the influence of larger chemical uses such as fertilizer. The relationship between non-point source pollution load and rainfall intensity is perfectly well explained by cubic regression with 0.33~0.81 coefficients of determination($R^2$). It is expected that the pollution loading function based on the long-term monitoring would be very useful with good accuracy in computing non-point source pollution load, where a rainfall intensity is highly variable.

Source Tracking of Fecal Contamination at Ansan Stream Using Multiple Antibiotic Resistance Analysis (Multiple Antibiotic Resistance Analysis를 이용한 안산천 분변성 미생물 오염원 추적)

  • Lee, Sang-Min;Lee, Jin;Kim, Moon-Il;Yoon, Hyun-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.827-833
    • /
    • 2011
  • In this study, fecal nonpoint pollutant sources tracking were conducted on Ansan stream. Multiple Antibiotic Resistance Analysis (MARA) method used in this study is based on the premise that fecal bacteria derived from intestine of human or animal has each different resistance for antibiotics. First of all, a database for known sources should be established to use the method and then, an unknown sample was applied on the database to find unknown sources by statistical analysis. The Ansan stream was considered with divided condition into three parts: upper (livestock farming area), mid (old section of the city), and downstream (new section of the city) to search an environmental influence of the stream basin. As results of the statistical analysis, it could be estimated that the upper stream area was influenced by animals due to the nature of influence for the livestock farms located in this area because livestock were classified as percentages of 45.8% in 3-way method divided into livestock, pet and human. In case of midstream and downstream, the human influence was remarkable as percentage of 60% and 80%, respectively. From these results, it could be judged that the MARA method is useful in source tracking the non-point pollutant sources because the MARA results correspond to which predictable non-point pollutant sources by a field study. Also, it is expected that a more effective source tracking will be possible as establishing database of each area.

Delivered Pollutant Loads of Point and Nonpoint Source on the Upper Watershed of Lake Paldang - Case Study of the Watershed of Namhan River and Gyeongan Stream (팔당호 상류유역의 점·비점오염원 유달부하 특성 - 남한강·경안천 수계를 대상으로)

  • Park, Ji Hyoung;Kong, Dong Soo;Min, Kyung Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.750-757
    • /
    • 2008
  • This study is conducted to characterize and evaluate delivered pollutant loads of point and nonpoint source on the upper watershed of lake paldang. The study area consists of 12 watersheds in Namhan-river and Kyungahcheon, which are approximately 80% of total area of Namhan-river and Kyungahcheon. Based on daily delivered loads from watersheds, 61% of $BOD_5$, 81% of T-N and 70% of T-P were from nonpoint sources, suggesting that delivered loads of nonpoint pollutants be crucial to water quality. On the other hand, 78% of $BOD_5$, 92% of T-N and 87% of T-P as delivered load were from nonpoint sources in an upper watershed of Namhan-river, while 48% of $BOD_5$, 70% of T-N and 57% of T-P as delivered load were from nonpoint sources in a lower watershed of Namhan-river, suggesting higher dependency of point sources than upper watershed of Namhan-river. In the characteristic of delivered loading pollutants from point and nonpoint pollution sources, delivered load of nonpoint pollutants differed significantly by seasonal flow, and as though discharged load of point pollutants were yearly uniform, delivered load of point pollutants was found to be flow-dependent because its delivery ratio was changed.

Identification of pollutant sources using water quality and stable isotope ratios of inflow tributaries in the lower reaches of the Han-River

  • Hong, Jung-Ki;Lee, Bo-Mi;Son, Ju Yeon;Park, Jin-Rak;Lee, Sung Hye;Kim, Kap-Soon;Yu, Soon-Ju;Noh, Hye-ran
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.65-76
    • /
    • 2019
  • Despite the expansion of sewage treatment facilities to reduce pollutants in the tributaries of the Han River, water pollution accidents such as fish deaths continue to frequently occur. The purpose of this study was to identify the pollutant sources using water quality and stable isotope ratio (${\delta}^{15}N$, ${\delta}^{13}C$, ${\delta}^{15}N-NH_4$, ${\delta}^{15}N-NO_3$) analysis results in the three inflow tributaries (Gulpocheon (GP), Anyangcheon (AY) and Sincheon (SC)) of the Han River. Water quality was analyzed in June and October from 2013 to 2017, and the results showed that the concentrations of nutrients, such as T-N, $NO_3-N$, and T-P, were increased at GP4, AY3, SC3, and SC4, which lie downstream of sewage treatment facilities. The results of ${\delta}^{15}N$ for June 2017 indicated that the source of nitrogen was sewage or livestock excreta at GP4 and SC4, and organic fertilizers at AY3 and SC3. ${\delta}^{15}N-NO_3$ results suggested that the source of nitrogen was related to organic sewage, livestock or manure at GP4, AY3 and SC4. Therefore, GP4 and SC4 were more influenced by effluent from sewage treatment facilities than by their tributaries, AY3 and SC3 were considered to be influenced more by their tributary than effluent from sewage treatment facilities. With the results of this study, the source of contamination (sewage treatment facility effluent) of river inflow downstream of Han River could be confirmed using water quality and stable isotope ratio.

Analysis of Runoff Characteristics of Non-point Sources Pollutant and Application of BMP Using BASINS/WinHSPF Model (BASINS/WinHSPF 모형을 이용한 비점오염물질 유출특성 분석과 최적관리기법 적용)

  • Kim, Min Joo;Kim, Tae Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.2
    • /
    • pp.88-100
    • /
    • 2014
  • This study analyzed runoff characteristics of non-point sources pollutant and evaluated removal of pollution by BMP(Best Management Practice) using BASINS/WinHSPF model. Hourly meterological data including input data was provided from 2010 to 2011 year to run HSPF model in Miho stream watershed. As the results of calibration and validation of the model, the model could be successfully performed to simulate the flow and water quality parameters. The apprehensive area of non-point source pollution was chosen by non-point source pollution per area of a tributary to the Miho stream and applied constructed wetland in area chosen. Three scenarios were based on installation area of an constructed wetland and HSPF model would be applied to estimate the pollutant removals through the constructed wetland. The removal rates of pollutants through the constructed wetland were estimated with the runoff and water quality parameters by the comparisons of before and after the constructed wetland application.

Estimation of the Pollutant Removal Efficiency in a Buffer Strip Using a SWAT Model

  • Lee, Eun-Jeong;Choi, Kyoung-Sik;Kim, Tae-Geun
    • Environmental Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.61-67
    • /
    • 2011
  • The water quality from nonpoint source run off results from different land use types has been studied. The construction of a buffer strip is one method of nonpoint source pollutant control. The Soil and Water Assessment Tool (SWAT) model has been applied to estimate the pollutant removal through the buffer strip. When the non-business land has been changed into grass to form a buffer-strip, the change of land use effects the results of the model according to measures of the water quality. The data from a water level station within the watershed in the years 2006 and 2007 was used for calibration and validation of the model. Under the rainfall conditions in 2007, the removal rates of SS, BOD, TN, TP were 11.5%, 9.5%, 1.2%, and 4.5%, respectively. During the rainy days, the removal rates at the buffer strip were 92.3% of SS, 91.2% of BOD, 82.4% of TN, and 83.5% of TP. The pollutants from nonpoint sources were effectively removed by over 80% as they passed through the buffer strips. Rainfall resulted in soil erosion, which led to an increase in the SS concentration, therefore, the construction of buffer strips protected the streams from SS inflows. Since TN concentrations are affected by the inflows of ground water and the N concentration of the rainfall, the removal rate of TN was relatively lower than for the other pollutants.

Establishment of Rainfall and Contaminants Runoff Modeling System for the Joman River Watershed Using SWMM (SWMM을 이용한 조만강 유역 강우-오염물 유출모델링시스템 구축)

  • Lee, Yong-Chin;Yoon, Young-Sam;Lee, Nam-Joo
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.983-992
    • /
    • 2009
  • The purpose of the present study is to analyze pollutant runoff characteristics from non-point sources in Joman River basin. The present study contains analyzed results of rainfall and SS, BOD, COD, TN, TP runoff from Joman River basin. This study contains a sensitivity analysis of parameters that affect the simulation results of rainfall and pollutants runoff. Result of the sensitivity analysis shows that proportion of watershed and impervious areas is the most sensitive to peak discharge and total flowrate for rainfall runoff and that WASHPO is the most sensitive parameter for pollutants runoff. For parameter estimation and verification, flowrate and water quality is measured at the Kangdong Bridge in Haeban stream. A single rainfall event is use to perform parameter estimation and verification. Results of the present study show that total pollutant loads of Joman River basin is 11,600 ton of SS, 452 ton of BOD, 1,084 ton of COD, 515 ton of TN, and 49 ton of TP, respectively. In addition, it is found that contribution ratio of non point source and total source is 89% of SS, 63% of BOD, 61% of COD, 21% of TN, and 32% of TP, respectively.

Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin (영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.