Analysis of the composition of trail pheromone secreted from live Camponotus japonicus by HS-SPME GC/MS (HeadSpace-Solid Phase MicroExtraction Gas Chromatography/Mass Spectrometry) (HS-SPME GC/MS법을 이용한 일본왕개미의 trail pheromone 성분 분석)

  • Park, Kyung-Eun;Lee, Dong-Kyu;Kwon, Sung Won;Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.292-299
    • /
    • 2012
  • GC/MS has been utilized for many applications due to great resolution and reproducibility, which made it possible to build up the database of mass spectrum, while HS-SPME has the advantage of solventfree extraction of volatile compounds. The combination of these two methods, HS-SPME GC/MS, enabled many scientific applications with various possibilities. In this study, the analysis of trail pheromone excreted from live Camponotus japonicus with the feature of solvent-free extraction was carried out and the optimization for this analysis was performed. The major compounds detected were n-decane, n-undecane, and n-tridecane. Optimization for the best detection of these hydrocarbons was processed in the point of SPME parameter (selection of fiber, extraction temperature, extraction time, etc.). The advantage of the analysis of live sample is to analyze phenomenon right after it is excreted by ants. But the experimental process has restriction of extraction temperature and time because of the analysis of live ants. Establishing the process of HS-SPME GC/MS applied to live samples shown in this study can be a breakthrough for the ecofriendly and ethical research of live things.

Analysis of Aroma Patterns in Muskmelon at Different Storage Temperatures Using a Mass Spectrometry-based Electronic Nose (질량분석기 기반 전자코를 이용한 저장 온도별 머스크멜론의 향기 패턴 분석)

  • Youn, Aye-Ree;Noh, Bong-Soo;Kim, Byeong-Sam;Kwon, Ki-Hyun;Kim, Jong-Hoon;Kim, Sang-Hee;Choi, Duck-Joo;Cha, Hwan-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.419-425
    • /
    • 2011
  • Changes in the flavor of muskmelons stored at different temperatures were examined to judge aroma patterns during storage. A mass-spectrometry based electric nose was used to distinguish the subtle differences in the muskmelon's volatile compounds. The data were used for a discriminant function analysis (DFA), and then the partial least square algorithm was used for a quantitative analysis. Volatile components in the muskmelons increased with storage, and the first discriminant function score (DF1: $r^2$=99.88%, F=3072.5) moved from a positive position to a negative position as the storage period increased. The proper point of maturity was anticipated as the $28^{th}$ day at 0$^{\circ}C$, $21^{st}C$ day at 4 and 7$^{\circ}C$, and $14^{th}$ day at 10$^{\circ}C$. Also, using the DF1 score we could predict the general tendency (vitamin C, stem moisture, acidity) of the muskmelons. The electronic nose revealed that the major volatile compounds that changed during storage of the melons were ethyl ethyl acetate, butyl acetate, nonanol, dodecanoic acid, hexadecanoic acid and tricosane. The amount of volatile compounds detected increased during storage.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Seismic Data Processing For Gas Hydrate using Geobit (Geobit을 이용한 가스 하이드레이트 탐사자료 처리)

  • Jang Seong-Hyung;Suh Sang-Yong;Chung Bu-Heung;Ryu Byung-Jae
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.4
    • /
    • pp.184-190
    • /
    • 1999
  • A study of gas hydrate is a worldwide popular interesting subject as a potential energy source. A seismic survey for gas hydrate have performed over the East sea by the KIGAM since 1997. General indicators of natural submarine gas hydrates in seismic data is commonly inferred from the BSR (Bottom Simulating Reflection) that occurred parallel to the see floor, amplitude decrease at the top of the BSR, amplitude Blanking at the bottom of the BSR, decrease of the interval velocity, and the reflection phase reversal at the BSR. So the seismic data processing for detecting gas hydrates indicators is required the true amplitude recovery processing, a accurate velocity analysis and the AVO (Amplitude Variation with Offset) analysis. In this paper, we had processed the field data to detect the gas hydrate indicators, which had been acquired over the East sea in 1998. Applied processing modules are spherical divergence, band pass filtering, CDP sorting and accurate velocity analysis. The AVO analysis was excluded, since this field data had too short offset to apply the AVO analysis. The accurate velocity analysis was performed by XVA (X-window based Velocity Analysis). This is the method which calculate the velocity spectrum by iterative and interactive. With XVA, we could determine accurate stacking velocity. Geobit 2.9.5 developed by the KIGAM was used for processing data. Processing results say that the BSR occurred parallel to the sea floor were shown at $367\~477m$ depths (two way travel time about 1800 ms) from the sea floor through shot point 1650-1900, the interval velocity decrease around BSR and the reflection phase reversal corresponding to the reflection at the sea floor.

  • PDF

Experimental Study for the Resonance Effect of the Power Buoy Amplitude (공진형 전력부이의 상하변위증폭 효과에 관한 실험적 연구)

  • Kweon, Hyuck-Min;Koh, Hyeok-Jun;Kim, Jung-Rok;Choi, Young-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.585-594
    • /
    • 2013
  • In this study, laboratory experiments and numerical simulations were conducted to test the performance of resonance power buoy system proposed by Kweon et al.(2010). The system is composed of a linear generator and a mooring buoy. The mover of the linear generator mainly has heave motion driven by vertical oscillation of the buoy. In this system, the velocity discrepancy between the mover and the buoy makes electricity. However, ocean wave energy as a natural resource around Korean peninsula is comparatively small and the driving force for producing electricity is not enough for commercialization. Therefore, it is necessary that the buoy motion be amplified by using resonance characteristics. In order to verify the resonance effects on the test power buoy, the experimental investigations were conducted in the large wave flume (length of 110 m, width of 8 m, maximum depth of 6 m) equipped with regular and random plunger wave generator. The resonance draft of test power buoy is designed for the corresponding period of incident wave, 1.96 sec. Regular wave test results show that the heave response amplitude operator(RAO) by a test buoy has the amplification of 5.66 times higher compared to the wave amplitude at the resonance period. Test results of random waves show that the buoy has the largest spectrum area of 20.73 times higher at the point of not the resonance period but the shorter one of 1.85 sec. Therefore this study suggests the resonance power buoy for wave power generation for commercial application in the case of the coastal and oceanic area with smaller wave energy.

Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy (라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구)

  • Kim, Jongwoo;Kim, Namgyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.130-134
    • /
    • 2019
  • In this paper, a laser-based non-contact load cell is newly developed for measuring forces in prestressed concrete tendons. First, alumina particles have been sprayed onto an empty load cell which has no strain gauges on it, and the layer has been used as a passive stress sensor. Then, the spectral shifts in fluorescence spectroscopy have been measured using a laser-based spectroscopic system under various force levels, and it has been found that the relation of applied force and spectral shift is linear in a lab-scale test. To validate the field applicability of the customized load cell, a full-scale prestressed concrete specimen has been constructed in a yard. During the field test, it was, however, found that the coating surface has irregular stress distribution. Therefore, the location of a probe has to be fixed onto the customized load cell for using the coating layer as a passive stress sensor. So, a prototype customized load cell has been manufactured, which consists of a probe mount on its casing. Then, by performing lab-scale uniaxial compression tests with the prototype load cell, a linear relation between compression stress and spectrum shift at a specific point where laser light had been illuminated has been detected. Thus, it has a high possibility to use the prototype load cell as a force sensor of prestressed concrete tendons.

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Inelastic Dynamic Analysis of Structure Subjected to Across-Wind Load (풍직각방향 풍하중이 작용하는 구조물의 비탄성 동적 해석)

  • Ju-Won Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2023
  • In this study, fluctuating wind velocity for time history analysis is simulated by a single variate, single-dimensional random process using the KBC2022 spectrum about across-wind direction. This study analyzed and obtained the inelastic dynamic response for structures modeled as a single-degree-of-freedom system. It is assumed that the wind response is excellent in the primary mode, the change in vibration owing to plasticization is minor, along-wind vibration and across-wind vibration are independent, and the effect of torsional vibration is small. The numerical results, obtained by the Newmark-𝛽 method, shows the time-history responses and trends of maximum displacements. As a result of analyzing the inelastic dynamic response of the structure with the second stiffness ratio(𝛼) and yield displacement ratio (𝛽) as variables, it is identified that as the yield displacement ratio (𝛽) increases when the second stiffness ratio is constant, the maximum displacement ratio decreases, then reaches a minimum value, and then increases. When the stiffness ratio is greater than 0.5, there is a yield point ratio at which the maximum displacement ratio is less than 1, indicating that the maximum deformation is reduced compared to the elastically designed building even if the inelastic behavior is permitted in the inelastic wind design.

Application of peak based-Bayesian statistical method for isotope identification and categorization of depleted, natural and low enriched uranium measured by LaBr3:Ce scintillation detector

  • Haluk Yucel;Selin Saatci Tuzuner;Charles Massey
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3913-3923
    • /
    • 2023
  • Todays, medium energy resolution detectors are preferably used in radioisotope identification devices(RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32-4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5-74.4% for 238U and 4.7-10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U-Th samples if a medium energy resolution detector is was in the measurements.

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.