• Title/Summary/Keyword: point defects

Search Result 497, Processing Time 0.028 seconds

Construction of the Facilities Management System by Video Structuring (동영상자료 구조화에 의한 시설물관리시스템 구축)

  • Yoo, Hwan-Hee;Choi, Kyoung-Ho;Koo, Heung-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.4 s.31
    • /
    • pp.69-74
    • /
    • 2004
  • By the expanding of infrastructure caused by urbanization, new technologies are required to manage various kinds of facilities. GIS has been appraised as valuable technology for facilities management since the 1990s. Therefore, the long and mid term GIS construction plan has been established by the national government and the local government. Some facilities management systems have been built and developed for suppling user-friendly functions. From this point of view, the information system based on the video sequences is considered a more effective way to improve the defects of conventional GIS using the digital map or the image as the base map. Using the video sequences as a base map, the availability of the system ill be increased because the real world information can be furnished to the users. In this study, through the connection between the GIS data, the digital map and the attribute data, and the video sequences taken from the airship using the video geo-referencing and the object tracking, we developed the facilities management system as a prototype which can effectively manage the road utilities. We also presented potentialities of the suggested system for facility management based on the video sequences.

  • PDF

Quality Control Probes for Spot-Uniformity and Quantitative Analysis of Oligonucleotide Array

  • Jang, Hyun-Jung;Cho, Mong;Kim, Hyung-Hoi;Kim, Cheol-Min;Park, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.7
    • /
    • pp.658-665
    • /
    • 2009
  • Quality control QC for spot-uniformity is a critical point in fabricating an oligonucleotide array, and quantification of targets is very important in array analysis. We developed two new types of QC probes as a means of confirming the quality of the uniformity of attached probes and the quantification of targets. We compared the signal intensities and fluorescent images of the QC and target-specific probes of arrays containing only target-specific probes and those containing both QC and target-specific probes. In a comparison of quality control methods, it was found that the arrays containing QC probes could check spot-uniformity or spot defects during all processes of array fabrication, including after spotting, after washing, and after hybridization. In a comparison of quantification results, the array fabricated by the method using QC probes showed linear and regular results because it was possible to normalize variations in spot size and morphology and amount of attached probe. This method could avoid errors originating in probe concentration and spot morphology because it could be normalized by QC probes. There were significant differences in the signal intensities of all mixtures (P<0.05). This result indicates that the method using QC probes is more useful than the ordinary method for quantification of mixed target. In the quantification of mixed targets, this method could determine a range for mixed targets of various amounts. Our results suggest that methods using QC probes for array fabrication are very useful to the quality control of spots in the fabrication processes of quantitative oligonucleotide arrays.

Enhanced Hole Concentration of p-GaN by Sb Surfactant (Sb 계면활성제에 의한 p-GaN 박막의 홀농도 향상)

  • Kim, J.Y.;Park, S.J.;Moon, Y.B.;Kwon, M.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.271-275
    • /
    • 2011
  • The role and effect of Sb surfactant on structure and properties of p type gallium nitride (GaN) epilayers have been investigated. It was found that there was a increase of hole concentration with Sb surfactant, compared to typical Mg-doped p-GaN. The structural and optical quality of p-GaN epilayers were accessed by x-ray diffraction, photoluminescence and atomic force microscope measurements. The results clearly show that the increase in hole concentration with Sb surfactant can be resulted from decrease in the dislocations and nitrogen point defects.

Error Minimized Laser Beam Point Detection Using Mono-Camera (한 개의 카메라를 이용한 최소오차 레이저 빔 포인터 위치 검출)

  • Lee, Wang-Heon;Lee, Hyun-Chang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.6
    • /
    • pp.69-76
    • /
    • 2007
  • The main stream of presentation is interrupted because of the direct manipulation of their PC frequently so as to control the screen and file open and so on. A variety of products have been developed to solve these inconveniences of the conventional laser beam pointer [LBP] by simply adding a mouse function to the previous LBP. However. the LBPs fully supporting a mouse function are not yet appeared. In this paper. we developed the LBP fully fulfilling a mouse function using mono-camera as well as a robust image processing and analyzed the position detection accuracy. Finally we verified the developed LBP does not only fulfill a mouse function but also solve the defects of the current laser pointer such as inconvenient installation and Position detection errors due to the illumination and viewing direction changes.

  • PDF

Chemical Mechanical Polishing Characteristics of Mixed Abrasive Silica Slurry (MAS) by adding of Manganese oxide (MnO2) Abrasive (산화망간이 첨가된 혼합 연마제 실리카 슬러리의 산화막 CMP 특성)

  • Seo, Yong-Jin
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1175-1181
    • /
    • 2019
  • In this paper, we have studied the chemical mechanical polishing(CMP) characteristics of mixed abrasive silica slurry(MAS) retreated by adding of manganese oxide(MnO2) abrasives within 1:10 diluted silica slurry. A slurry designed for optimal performance should produce high removal rates, acceptable polishing selectivity with respect to the underlying layer, low surface defects after polishing, and good slurry stability. The polishing performances of MnO2 abrasive-added MAS are evaluated with respect to their particle size distribution, surface morphology, and CMP performances such as removal rate and non-uniformity. As an experimental result, we obtained the comparable slurry characteristics compared to original silica slurry in the view-point of high removal rate and low non-uniformity. Therefore, our proposed MnO2-MAS can be useful to save on the high cost of slurry consumption since we used a 1:10 diluted silica slurry.

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Cloud storage-based intelligent archiving system applying automatic document summarization (문서 자동요약 기술을 적용한 클라우드 스토리지 기반 지능적 아카이빙 시스템)

  • Yoo, Kee-Dong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.3
    • /
    • pp.59-68
    • /
    • 2012
  • Zero client-based cloud storage technology is gaining much interest as a tool to centralized management of organizational documents nowadays. Besides the well-known cloud storage's defects such as security and privacy protection, users of the zero client-based cloud storage point out the difficulty in browsing and selecting the storage category because of its diversity and complexity. To resolve this problem, this study proposes a method of intelligent document archiving by applying an algorithm-based automatic topic identification technology. Without user's direct definition of category to store the working document, the proposed methodology and prototype enable the working documents to be automatically archived into the predefined categories according to the extracted topic. Based on the proposed ideas, more effective and efficient centralized management of electronic documents can be achieved.

BRCA1 Gene Mutations and Influence of Chemotherapy on Autophagy and Apoptotic Mechanisms in Egyptian Breast Cancer Patients

  • Abdel-Mohsen, Mohamed Ahmed;Ahmed, Omiama Ali;El-Kerm, Yasser Mostafa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1285-1292
    • /
    • 2016
  • Background: It is well established that mutations in the BRCA1 gene are a major risk factor for breast cancer. Induction of cancer cell death and inhibition of survival are the main principles of cancer therapy. In this context, autophagy may have dual roles in cancer, acting on the one hand as a tumor suppressor and on the other as a mechanism of cell survival that can promote the growth of established tumors. Therefore, understanding the role of autophagy in cancer treatment is critical. Moreover, defects in apoptosis, programmed cell death, may lead to increased resistance to chemotherapy. Purpose: The aim of the present study was to detect BRCA1 gene mutations in order to throw more light on their roles as risk factors for breast cancer in Egypt. Secondly the role of autophagy and apoptosis in determining response to a fluorouracil, doxorubicin, cyclophosphamide (FAC) regimen was investigated. Materials and Methods: Forty-five female breast cancer cases and thirty apparently healthy females were enrolled in the present study. Serum levels of autophagic biomarkers, Beclin 1 and LC3 as well as the serum levels of apoptosis biomarkers Bcl-2 and Caspase-3 were measured before and after chemotherapy. Results: BRCA1 mutations were found in 5 (16.7%) and 44 (99.8%) of the controls and cancer patients, the most frequent being 5382insC followed by C61G and 185 delAG. The results revealed that chemotherapy caused elevation in serum concentration levels of the autophagic biomarkers (Beclin 1 and LC3). This elevation was associated with a significant decrease in serum concentration levels of Bcl-2 and significant increase in caspase-3 concentration levels (apoptotic markers). Conclusions: The results of the present study indicate a very high level of BRCA mutations in breast cancer cases in Egypt and point to involvement of autophagic and apoptotic machinery activation in response to FAC chemotherapy.

Developing Product Liability Response Strategies of SMEs using PEST-SWOT-AHP analysis (PEST-SWOT-AHP 분석을 이용한 중소제조기업의 제조물책임 대응전략 수립)

  • Seo, JunHyeok;Bae, SungMin
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.2
    • /
    • pp.11-18
    • /
    • 2016
  • Product liability (PL), which began enforcement in 2002, refers to the legal responsibility of the manufacturers or sellers (wholesales or retailers) for the property damage or bodily harm caused by their product. With a strong enforcement of the Product Liability (PL) Act, companies are required to structure and operate a response system to defend or prevent product accidents efficiently, but small and medium enterprises (SMEs) are unable to respond more aggressively due to limitation of management resources. In this manner, it is important to develop response strategies for SMEs to efficiently cope with the PL Act. In this paper, the PEST (Political, Economic, Social, and Technological) analysis is performed to reveal the impact of the PL Act on SMEs in macro-economic point of view. To formulate SME's PL response strategy, SWOT analysis is performed to categorize each factors from PEST analysis and AHP is applied to identify the intensities of SWOT factors. The prioritized SWOT factor, results of PEST-SWOT-AHP analysis, are used to formulate SME's PL response strategies. The study results are briefly summarized as follows. To reduce product defects, it is necessary for SMEs to formulate PL response strategies for each phase of the product life cycle by continuously collecting and analyzing PL cases in the same industry or for similar products. In addition, SMEs should invest more technological effort to ensure product safety. Further, SMEs should spread PL awareness to all staff members by training internal PL experts. Moreover, a SME should enroll in PL insurance and spread this information to its customers so that they become aware that the company is proactively conforming to the PL law.

Microstructure Characterization of Ternary ZnSSe/GaAs Epilayer Grown by MBE (MBE로 성장시킨 3원계 ZnSSe/GaAs 에피층의 미세구조 특성)

  • Lee, Hwack-Joo;Ryu, Hyun;Park, Hae-Sung;Kim, Tae-Il
    • Applied Microscopy
    • /
    • v.25 no.3
    • /
    • pp.75-81
    • /
    • 1995
  • The microstructural characterization of ternary $ZnS_{x}Se_{1-x}$(x=0.085) on GaAs(001) substrate grown up to $2{\mu}m\;at\;300^{\circ}C$ by molecular beam epitaxy(MBE) which has a single growth chamber was investigated by high resolution transmission electron microscope (HRTEM) working at 300 kV with point resolution of 0.18nm. The interface in the ZnSSe/GaAs specimen maintains a pseudomorphism with the substrate, but the epilayer has high density of stacking faults and moire fringes. The pits which had formed along <111> direction were found at the interface of ZnSSe/GaAs. The pits were responsible for producing defects in both epilayer and substrate. The wavy interface which has the difference of 15nm in height was found to maintain the pseudomorphism with the substrate and no stacking faults were found around the interface. However there exists faint and fine moire fringes in the epilayer near interface.

  • PDF