Behavior of Geogrid-Reinforced Soil with Cyclic plate Load Test (반복 평판재하시험을 통한 지오그리드 보강지반의 거동 특성)

  • 신은철;김두환;이상조;이규진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.285-292
    • /
    • 1999
  • The cyclic plate load test were peformed to determine the behavior of reinforced soft ground with multiple layers of geogrid. Five series of test were conducted with varying the soil profile conditions which including the ground level, type of soil, and the thickness of each soil layer. The plate load test equipment was slightly modified to apply the cyclic load. Based on the cyclic plate load test results, the bearing capacity ratio(BCR), subbase modules, shear modules, the elastic rebound ratio, and reinforcing parameters are presented.

  • PDF

Estimation of deformation modulus for rock mass using stress distribution under ground in Large Plate Load Test (대형평판재하시험의 지중응력 측정결과를 이용한 연암의 변형계수 산정)

  • Park, Won-Tae;Lee, Min-Hee;Choi, Yong-Kyu;Kim, Seok-Chan;Kim, Jung-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.539-545
    • /
    • 2010
  • The field plate test has a good potential for determining since it measures both plate pressure and settlement. The deformation modulus of rock mass is differently measured for status of structures. The values of deformation modulus are obtained from laboratory test (uniaxial and triaxial test) and field test (pressuremeter test). Plate load test should be conducted by different loading plate sizes for geological structure of rock mass and scale of structures. In this paper, large plate load tests were performed to predict of structure's behavior and evaluate the ultimate bearing capacity of the foundation on soft rock. Simultaneously, deformation modulus of rock mass was estimated by back analysis of stresses measured in field test under rock mass. Finally, we verified the validation of deformation modulus of rock mass through result of large plate load test and numerical simulation.

  • PDF

Rating of A Plate Girder Bridge through Load Test (강거더교의 재하시험을 통한 내하력평가)

  • Juhn, Gui Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.1
    • /
    • pp.89-97
    • /
    • 1998
  • This paper presents the results of the load test performed on a steel plate girder bridge and suggests the procedure of bridge rating through the load test. In general the girder bridge resist the loads as a complex three-dimensional structural system. Therefore the test results are analyzed for the longitudinal and the transverse response characteristics. The bending moments based on the beam analysis are compared with the measured values for longitudinal response characteristics. The lateral load distribution characteristics are assessed based on the load test results for transverse response characteristics. Also the rating of the test bridge is performed by using the suggested rating procedure which considers the actual response characteristics of the bridge. The suggested procedure can be used for understanding of actual response characteristics and evaluating load carrying capacity of the steel plate girder bridge.

  • PDF

Structural Behavior of RC Beam Strengthened with Steel Plate (강판 휨보강된 철근 콘크리트보의 구조적 거동)

  • 오병환;강동욱;조재열;채성태;이명규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.598-604
    • /
    • 1997
  • In recent years, strengthening by epoxy-bonded steel plates, carbon fiber sheets, aramid fiber sheets and so on, is spotlighted. Among them, the method using steel plates is most widely applied. Most studies have dealt with strengthening by epoxy-bonded steel plates. However the actual behavior of strengthened RC beams are not well established. Particularly, the studies on the separation load thar affects failure load of the beam are relatively insufficient. In this study, test parameters are the magnitude of pre-load, plate length, plate thickness, existence and spacing of anchor bolt, the number of plate layer and the height of side strengthening, 17reinforced concrete beams are strengthened by steel plates according to test parameters. Deflection, failure load, strains of reinforcing bar, concrete and plate are measured from tests(4 points loading). The failure mode, and separation load are analyzed from these measured data. The difference between Robert's theory and test results is discussed, and the prediction equation for separation load in the case of rip off is proposed.

  • PDF

A Study on the Strength Comparison of Steel Pipe Support using the Structural Analysis Program (구조해석에 의한 파이프서포트의 내력비교에 관한 연구)

  • Paik, Shin-Won;Park, Jong-Keun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.67-71
    • /
    • 2008
  • Formwork is a temporary structure that supports its weight and that of fresh concrete as well as construction live loads. Slab formwork consists of sheathing, stringer, hanger and shore. In construction site, pipe supports are usually used as shores which are consisted of the slab formwork. In this study, compressive strength of 80 pipe supports was measured by knife edge test and plate test. Buckling load of pipe supports was analyzed by structural analysis program(MlDAS). Theoretical buckling load with/without initial deformation was got by theoretical analysis. According to these results, buckling load which was analyzed by structural analysis program(MlDAS) was larger than compressive strength of knife edge test and plate test. Theoretical buckling load without initial deformation was larger than compressive strength of knife edge test and plate test. But Theoretical buckling load with initial deformation was lower than compressive strength of knife edge test and plate test. Initial deformation equation for test method according to the pipe support length was suggested. Therefore, the present study results will be used to design the slab formwork safely.

Evaluation of Ground Characteristic Using the New Developed Screw Plate Load Test Device (새롭게 개발된 스크류재하시험장치를 이용한 지반특성 파악)

  • Lee, Nam-Woo;Hwang, Woong-Ki;Choi, Yong-Kyu;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.5-17
    • /
    • 2011
  • Sampling disturbance can often introduce considerable errors in the laboratory estimation of geotechnical properties of soils. Accordingly, it causes inappropriative results in analysing field behavior. Therefore, a screw plate load test, one of in-situ test technique, is developed in this study, because in-situ testing techniques have advantages for the estimation of reliable geotechnical parameters. The screw plate load test, which was modified from the plate load test, conducts an experiment underneath ground by inserting a spiral type of auger screw. In this study, the structure and characteristics of the screw plate load test device are introduced in detail and the reliability of the device is examined through the analysis of the laboratory test results.

Application of Scale Effect in Estimating Bearing Capacity and Settlement of Footing from Plate-Load Test (평판재하시험으로부터 실제기초의 지지력 및 침하량 산정시 Scale Effect)

  • 정형식;김도열
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.350-357
    • /
    • 2002
  • The scale effect should be considered to determine the bearing capacity and settlement of footings from Plate-Load Test, because of the size difference between a footing and a loading plate. To analyze characteristics of bearing capacity and settlement according to the difference of loading plate sizes, model tests were peformed with four different sizes of square plate, which is B=10, 15, 20 and 25cm respectively, on five different kinds of subsoil, which is pure sand(100:0), sand-clay mixed soil(75:25, 50:50, 25:75), and pure clay(0:100). Based on the analyzed results, this paper also proposed a method of bearing capacity and settlement determination, where scale effect is considered depending on the mixing ratio of sand and clay. Applying the formular proposed in this research to field problems, it is expected that evaluation of bearing capacity and settlement of footings can be more reliable and more economic construction can be achieved.

  • PDF

A Scale-Effect of O-Cell Pile Load Test with Variable End Plate (가변선단재하판을 이용한 양방향말뚝재하시험의 치수 효과)

  • Joo, Yong-Sun;Kim, Nak-Kyung;Kim, Ung-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.884-890
    • /
    • 2009
  • The bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of the bi-direction can be known by using the loading of the end plate and two step procedures. The first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell, operated with end plate of 3 type on sand layer according to the relative density, loose, medium and dense conditions.

  • PDF

Estimation on Bearing Capacity of Environmentally Sustainable Geotextile Gabion Using Oystershell (굴패각을 이용한 친환경적 지오텍스타일 게비언의 지지력 평가)

  • Shin, Eun-Chul;Park, Jeong-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.44-52
    • /
    • 2007
  • Recently, oystershell wastes cause serious environmental problem and the need for the researches on the recycling of oystershell have been increased and various methods are already in operation. Field plate bearing tests and numerical analysis were performed to investigate the bearing capacity of oystershell filled geotextile gabion which utilized the waste oystershell at the coastal oyster farm site. The waste oystershell mixed soil specimens were prepared for the laboratory test and field test in terms of varying blending ratio of granite soil and oystershell. Based on the cyclic plate load test results, the spring constant, subgrade modulus of ground, and the reinforcing parameters were determined. The field plate load test results indicate that the bearing capacity of the soil ground with the oystershell mixed ratio of 20% is greater than that of the original ground. Two-dimensional numerical analysis was evaluated the expected deformation in the given conditions. Analysis results show a similar characteristics on bearing capacity with the results of the field plate load test. These findings suggest that the oystershells are very promising construction materials for landfill and earth embankment in coastal area.

An Experimental Study on the Relationship between Deformation and Relative Settlement for Weathered-granite (화강풍화토의 변형계수와 상대침하 관계식에 관한 실험적 연구)

  • Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2013
  • To predict the real bearing capacity and settlement of the shallow foundation the plate load test results were used. But there is no field estimation method about igneous weathered soil and rock. Therefore, to predict the settlement equation, the plate load test about igneous weathered soil and rock was done in this study. To analyze the load ~ relative settlement curve by normalization, it did not use normal analysis method, but the load ~ relative settlement (s/B, s : settlement, B : breadth of plate) was used. As a result of normalization by load ~ relative settlement conception, the curve was regular regardless of plate diameter and it was suggested the relationship of in-situ soil condition and results.