• Title/Summary/Keyword: plasma-activated water

Search Result 31, Processing Time 0.027 seconds

Analysis of reactive species in water activated by plasma and application to seed germination

  • Choi, Ki-Hong;Lee, Han-Ju;Park, Gyungsoon;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.162.1-162.1
    • /
    • 2015
  • The use of plasma has increased in bio-application field in recent years. Particularly, water treated by arc discharge or atmospheric pressure plasma has been actively utilized in bio-industry. In this study, we have developed a plasma activated water generating system. For this system, two kinds of plasma sources; dielectric barrier discharge (DBD) plasma and arc discharge plasma have been used. The discharge energy was calculated using the breakdown voltage and current, and the emission spectrum was measured to investigate the generated reactive species. We also analyzed the amount of reactive oxygen and nitrogen species in water using the chemical methods and nitric oxide sensor. Finally, the influence of plasma generated reactive species on the germination and growth of spinach (Spinacia oleracea) was investigated. Spinach is a green leafy vegetable that contains a large amount of various physiologically active organic compounds. However, it is characterized with a low seed germination rate.

  • PDF

Effect of Plasma-activated Water Process on the Growth and Functional Substance Content of Lettuce during the Cultivation Period in a Deep Flow Technique System (담액수경재배 시스템에서 플라즈마수 처리가 상추의 생육 및 페놀류 함량에 미치는 영향)

  • Noh, Seung Won;Park, Jong Seok;Kim, Sung Jin;Kim, Dae-Woong;Kang, Woo Seok
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.464-472
    • /
    • 2020
  • We suggest a hydroponic cultivation system combined with a plasma generator to investigate the changes in the growth and functional substance content of lettuces during the cultivation period. Lettuce seedlings of uniform size were planted in semi-DFT after seeding for 3 weeks, and the plasma-activated water was intermittently operated for 1 hour at an 8 hours cycle for 4 weeks. Lettuces grew with or without plasma-activated water with the nutrient solution in hydroponics culture systems. Among the reactive oxygen species generated during plasma-activated water treatment, brown spots and necrosis appeared in the individuals closer to the plasma generating device due to O3, and there was no significant difference in the growth parameters. While the rutin and total phenolic content of the lettuce shoot grown in the nutrient solution were higher than that of the plasma-activated water, epicatechin contents in plasma-activated water were significantly greater than the nutrient solution. However, in the roots, all kinds of secondary metabolites measured in this work, rutin, epicatechin, quercetin, and total phenolic contents, were significantly higher in the plasma-activated water than the control. These results were indicated that the growth of lettuce was decreased due to the reactive oxygen species such as ozone in the plasma-activated water, but the secondary metabolites in the root zone increased significantly. It has needed to use this technology for the cultivation of root vegetables with the modified plasma-activated water systems to increase secondary metabolite in the roots.

Plasma bioscience for medicine, agriculture and hygiene applications

  • Eun Ha Choi;Nagendra Kumar Kaushik;Young June Hong;Jun Sup Lim;Jin Sung Choi;Ihn Han
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.817-851
    • /
    • 2022
  • Nonthermal biocompatible plasma (NBP) sources operating in atmospheric pressure environments and their characteristics can be used for plasma bioscience, medicine, and hygiene applications, especially for COVID-19 and citizen. This review surveyed the various NBP sources, including a plasma jet, micro-DBD (dielectric barrier discharge) and nanosecond discharged plasma. The electron temperatures and the plasma densities, which are produced using dielectric barrier discharged electrode systems, can be characterized as 0.7 ~ 1.8 eV and (3-5) × 1014-15 cm-3, respectively. Herein, we introduce a general schematic view of the plasma ultraviolet photolysis of water molecules for reactive oxygen and nitrogen species (RONS) generation inside biological cells or living tissues, which would be synergistically important with RONS diffusive propagation into cells or tissues. Of the RONS, the hydroxyl radical [OH] and hydrogen peroxide H2O2 species would mainly result in apoptotic cell death with other RONS in plasma bioscience and medicines. The diseased biological protein, cancer, and mutated cells could be treated by using a NBP or plasma activated water (PAW) resulting in their apoptosis for a new paradigm of plasma medicine.

Physical and Chemical Adsorption Properties for Tetracycline Using Activated Carbon with Nitrogen Plasma Treatment (질소 플라즈마 처리된 활성탄소를 이용한 테트라사이클린의 물리 및 화학 흡착 특성)

  • In Woo Lee;Seongjae Myeong;Chung Gi Min;Seongmin Ha;Seoyeong Cheon;Young-Seak Lee
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.8-15
    • /
    • 2024
  • In this study, nitrogen plasma treatment was performed in 5, 10, and 15 minutes to improve the tetracycline adsorption performance of activated carbon. All nitrogen plasma-treated activated carbons showed improved tetracycline adsorption compared to untreated activated carbons. The nitrogen functional groups in activated carbon lead to chemisorption with tetracycline via π-π interactions and hydrogen bonding. In particular, in the nitrogen plasma treatment at 80 W and 50 kHz, the activated carbon treated for 10 minutes had the best adsorption performance. At this time, the nitrogen content on the surface of the activated carbon was 2.03% and the specific surface area increased to 1,483 m2/g. As a result, nitrogen plasma treatment of activated carbon improved its physical and chemical adsorption capabilities. In addition, since the adsorption experimental results were in good agreement with the Langmuir isotherm and pseudo-second order model, it was determined that the adsorption of tetracycline on the nitrogen plasma-treated activated carbon was dominated by chemical adsorption through a monolayer. As a result, nitrogen plasma-treated activated carbon can be used as an adsorbent to efficiently remove tetracycline from water due to the synergistic effect of physical adsorption and proactive chemical adsorption.

Plasma Bioscience and Medicines (플라즈마 바이오과학 및 의학)

  • Choi, Eun Ha
    • Vacuum Magazine
    • /
    • v.2 no.4
    • /
    • pp.9-15
    • /
    • 2015
  • Nonthermal bio-compatible plasma (bioplasma) sources and their characteristics operating at atmospheric pressure could be used for biological cell interactions, especially for plasma bioscience and medicines. The electron temperatures and plasma densities of this bioplasma are measured to be 0.7 ~ 1.8 eV and $(3-5){\times}10^{14-15}cm^{-3}$, respectively. Herein, we introduced general schematic view of the plasma-initiated ultraviolet photolysis of water inside the biological solutions or living tissue for the essential generation mechanism of the reactive hydroxyl radical [OH] and hydrogen peroxide [$H_2O_2$], which may result in apoptotic cell death in plasma bioscience and medicines. Further, we surveyed the various nonthermal bioplasma sources including plasma jet, micro-DBD (dielectric barrier discharge) and nanosecond discharged plasma. The diseased biological protein, cancer, and mutated cells could be treated by these bioplasma sources or bioplasma activated water to result in their apoptosis for new paradigm of plasma bioscience and medicines.

A study on the fabrication of SOI wafer using silicon surfaces activated by hydro (수소 플라즈마에 의해 표면 활성화된 실리콘 기판을 이용한 SOI 기판 제작에 관한 연구)

  • Choi, W.B.;Joo, C.M.;Lee, J.S.;Sung, M.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3279-3281
    • /
    • 1999
  • This paper describes a method of direct wafer bonding using surfaces activated by a radio-frequency hydrogen plasma. The hydrogen plasma cleaning of silicon in the RIE mode was investigated as a pretreatment for silicon direct bonding. The cleaned silicon surface was successfully terminated by hydrogen, The hydrogen-terminated surfaces were rendered hydrophilic, which could be wetted by Dl water rinse. Two wafers of silicon and silicon dioxide were contacted to each other at room temperature and postannealed at $300{\sim}1100^{\circ}C$ in an $N_2$ atmosphere for 2 h. From the AFM results, it was revealed that the surface became rougher with the increased plasma exposure time and power. The effect of the plasma treatment on the surface chemistry was investigated by the AES analysis. It was shown that the carbon contamination at the surface could be reduced below 5 at %. The interfacial energy measured by the crack propagation method was 122 $mJ/m^2$ and 384 $mJ/m^2$ for RCA cleaning and hydrogen plasm, respectively.

  • PDF

Adsorption properties and metal growth aspects on the surface of activated carbon monolith electrochemically deposited with Ag

  • Oh, Won-Chun;Lim, Chang-Sung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.2
    • /
    • pp.37-46
    • /
    • 2004
  • The electrochemical adsorption of the Ag ions from aqueous solution on pelletized activated carbon monolith was investigated over wide range of operation time. The adsorption capacities of pelletized activated carbon monolith are associated with their internal porosity and are related properties such as surface area, pore size distribution. The chemical industry generates wastewater that contains toxic matters like heavy metals in small concentrations so that their economic recovery is not feasible. But, the method using activated carbon monolith can be used to withdrawal of heavy metals in waste water. After the electrochemical treatment, the quantitative properties in Ag ion solutions are also examined by pH concentration and studied elemental analysis by ICP-Atomic Emission Spectrometer and Energy Disperse X-ray (EDX) spectra. It is consider that the pH is very important factor at the reason of water pollutant with increasing acidity in industrial field. The result of quantitative analysis using Inductively Coupled Plasma-Atomic Emission Spectrometer of metal after electrochemical reaction in Ag ions solution depending on time are shown that the amount of Ag ions deposited was decreased with growth of Ag particles on the carbon surfaces as increasing electrochemically treated time. And, surface morphologies are investigated by scanning electron microscopy (SEM) to explain the changes in adsorption properties.

Improvement of Water Quality by Corona Discharge Plasma-activated Water in a Tilapia Recirculating Aquaculture System (코로나 방전-플라즈마 처리수의 틸라피아 순환여과양식시스템 수질 개선 효과)

  • You, Jin Ho;Mun, Seong Hee;Oh, Hyeon Ji;Park, Tae Sup;Kwon, Joon Yeong
    • Journal of Marine Life Science
    • /
    • v.5 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Disinfection and maintenance of rearing water in aquaculture is an essential element for the prevention of fish diseases. This is especially important in recirculating aquaculture systems (RAS) in which fish are reared at high density using recycled water. In this study, tilapia was reared in two different RAS (one with plasma generator - PW system, another without plasma generator - No PW system). In plasma treated group, UVT% of water was improved clearly, and the number of heterotrophic bacteria decreased significantly after 40 days. Total weight gain of tilapia in PW system was significantly higher, and other growth indicators were also relatively higher although not statistically significant. In addition, the fish in PW system had a 100% survival rate, and there were no histological differences between fish from both systems. Fish did not seem to be affected by the toxicity of ROS. In conclusion, it is expected that plasma water can effectively deactivate fish pathogens and improve the quality of rearing water.

Active Effect of Antivoagulant Effects in chaenomelis Fructus Water Extract (모과 추출물의 항응혈 활성)

  • Yoo, Ji-Hyun;Han, Sin-Hee;Kil, Gi-Jung
    • The Korea Journal of Herbology
    • /
    • v.24 no.2
    • /
    • pp.7-11
    • /
    • 2009
  • Objectives : This research was investigated anticoagulant effect of the Chaenomelis Fructus extract. Methods : To examine an active effect of anticoagulation in Chaenomelis Fructus extract, the study measured Prothrombin time(PT) and activated partial thromboplastin time (APTT) of human plasma in vitro and measured bleeding time and arterio-venous shunt model in rats in vivo. Results : Bleeding time of Chaenomelis Fructus extract in vivo had a significant increase as about 1.6 times and thrombus weight of Chaenomelis Fructus extract had a significant reduction of thrombus weight as 50%. Chaenomelis Fructus extract represented an effect of anticoagulation by operating on extrinsic pathway factor II, V, VII, X and intrinsic pathway factor VIII, IX, X, XI, XII in the coagulation system. Conclusions : Considering the above mentioned results, it is judged that a Chaenomelis Fructus extract has a control effect of thrombus creation.

A study of physical and chemical properties of internal accumulated material in water mains (상수관로 내부 오염물질의 물리화학적 특성 분석)

  • Bae, Cheol-Ho;Choi, Doo-Yong;Lee, Doo-Jin;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.589-600
    • /
    • 2014
  • Tuberculation and slime accumulated in water mains play an important role in modifying water quality of drinking water. Therefore, in this study, it was investigated that what materials were accumulated, and what components were included in the tuberculation and slime of water mains. The Various tuberculation and slime sample were collected from the 12 water mains to analyze their physical and chemical properties and crystal structure. As a analysis method, VSS(Volatile suspended solid), SEM(scanning electron microscope), EDS(Energy Dispersive X-ray spectroscope), ICP(Inductively Coupled Plasma Mass Spectrometer) and XRD(X-Ray Diffractomete) were used. The results of analysis on the samples, the representative materials were verified such as iron corrosion products, the fine sand particles generated during backwash, fine particles of activated carbon, aluminum used in coagulation process, and manganese included in raw water.