• Title/Summary/Keyword: plasma flow

Search Result 1,180, Processing Time 0.035 seconds

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Dry Etching of Ru Electrodes using O2/Cl2 Inductively Coupled Plasmas

  • Kim, Hyoun Woo
    • Corrosion Science and Technology
    • /
    • v.2 no.5
    • /
    • pp.238-242
    • /
    • 2003
  • The characteristics of Ru etching using $O_2/Cl_2$ plasmas were investigated by employing inductively coupled plasma (ICP) etcher. The changes of Ru etch rate, Ru to $SiO_2$ etch selectivity and Ru electrode etching slope with the gas flow ratio, bias power, total gas flow rate, and source power were scrutinized. A high etching slope (${\sim}86^{\circ}$) and a smooth surface after etching was attained using $O_2/Cl_2$ inductively coupled plasma.

The crystallinity of silicon films deposited at low temperatures with Remote Plasma Enhanced Chemical Vapor Deposition(RPECVD) (원거리 플라즈마 화학증착을 이용한 규소 박막의 결정성)

  • 김동환;이일정;이시우
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S1
    • /
    • pp.1-6
    • /
    • 1995
  • Polycrystalline Si films have been used in many applications such as thin film transistors(TFT), image sensors and LSI applications. In this research deposition of Si films at low temperatures with remote plasma enhanced CVD from Si2H6-SiF4-H2 on SiO2 was studied and their crystallinity was investigated. It was condluded that growth of crystalline Si films was favorable with (1) low Si2H6 flow rates, (2) moderate plasma power, (3) moderate SiF4 flow rates, (4) moderate substrate temperature, and (5) suitable method of surface cleaning.

  • PDF

Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber (PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구)

  • Lee, Jong-Chul;Kim, Youn-J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.4
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

Analysis and Performance Evaluation of DBD Actuator for Plasma Flow Control (플라즈마 유동 제어를 위한 DBD 엑츄에이터 해석 및 성능평가)

  • Lee, Chang-Wook;Yun, Su-Hwan;Kim, Tae-Gyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.290-293
    • /
    • 2012
  • The analysis and performance evaluation of DBD actuator for plasma flow control was described. The experimental apparatus was designed to measure the flow velocity as the discharge conditions, and to find out the optimal discharge condition of the DBD actuator. The average-velocity increased with increasing the discharge voltage. The experimental results was compared with CFD analysis.

  • PDF

An Experimental Study on dte Performance of Plasma-DeNOx Catalyst widt Supplying Hydrocarbon Reductant (탄화수소 환원제 공급에 따른 플라즈마-DeNOx 촉매의 성능에 관한 실험적 연구)

  • Hur, Dong-Han;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.93-99
    • /
    • 2008
  • To improve the performance of plasma-DeNOx catalyst, a research on active system was performed experimentally. Two hydrocarbons, propane and diesel, were used as a reductant in this study. First, using propane, basic performances of plasma-DeNOx catalyst such as the effects of plasma and C/N ratio were measured at the various engine operating conditions. NOx conversion of catalyst was improved as plasma power or C/N ratio was increased. Next, diesel was injected in the exhaust gas flow as a reductant. The first test using diesel as a reductant is spray visualization in a high temperature flow and spray images were utilized for analysis of posterior test results. To evaluate the effect of an injection direction, it was compared with 6 installation methods of diesel injector due to THC concentrations at the inlet of plasma. From the results, injector was installed toward downstream direction below the pipe. Then, basic performances of plasma-DeNOx catalyst with various injection quantities were measured. As an injection quantity was increased, $NO_2$ conversion of plasma reactor was increased but NOx conversion of catalyst was nearly zero. This was because NOx conversion of catalyst had slowed as time goes by due to black particles which had been adhered to the catalyst.

Study on Electron Temperature Diagnostic and the ITO Thin Film Characteristics of the Plasma Emission Intensity by the Oxygen Gas Flow (산소 유량별 플라즈마 방출광원 세기에 따른 전자온도 진단과 산화주석박막 특성연구)

  • Park, Hye Jin;Choi, Jin-Woo;Jo, Tae Hoon;Yun, Myoung Soo;Kwon, Gi-Chung
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.1
    • /
    • pp.92-97
    • /
    • 2016
  • The plasma has been used in various industrial fields of semiconductors, displays, transparent electrode and so on. Plasma diagnostics is critical to the uniform process and the product. We use the electron temperature of the various plasma parameters for the diagnosis of plasma. Generally, the range of the electron temperature which is used in a semiconductor process used the range of 1 eV to 10 eV. The difference of electron temperature of 0.5 eV has a influence in plasma process. The electron temperature can be measured by the electrical method and the optical method. Measurement of electron temperature for various gas flow rates was performed in DC-magnetron sputter and Inductively Coupled Plasma. The physical properties of the thin film were also determined by changing electron temperatures. The transmittance was measured using the integrating sphere, and wavelength range was measured at 300 ~ 1100 nm. We obtain the thin film of the mobility, resistivity and carrier concentration using the hall measurement system. As to the electron temperature increase, optical and electrical properties decrease. We determine it was influenced by the oxygen flow ratio and plasma.

One-Plate Type Hybrid Plasma Discharge Device with Heating Element (히터 일체형 하이브리드 단판형 플라즈마 방전소자)

  • Choi, Woo Jin;Choi, Eun Hye;Sung, Hyeong Seok;Kwon, Jin Gu;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

Experimental analysis on the characteristics of enthalpy probe immersed in arc plasma flow (아크 플라즈마 유동에 삽입된 엔탈피 탐침의 동작특성 실험)

  • Seo, Jun-Ho;Nam, Jun-Seok;Choi, Seong-Man;Hong, Bong-Gun;Hong, Sang-Hee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.12
    • /
    • pp.1240-1246
    • /
    • 2010
  • Enthalpy probe with the inner and outer diameters of 1.5 mm and 4.8 mm, respectively, is designed and used to measure the temperatures and velocities along the centerline of Ar arc plasma flow until the probe was destroyed. For this purpose, Ar arc plasma flow is generated by non-transferred type DC arc heater with the power level of 17 kW. From this experiment, it is shown that the designed enthalpy probe can measure the temperature and velocity of arc plasma flow up to 12,000 K and 600 m/s, respectively, without destroy of probe tip. In this extreme case, the arc plasma flow is calculated to transfer the heat flux of ${\sim}5{\times}10^7\;W/m^2$ to the probe based on the heat and thermal boundary equations near the forward stagnation point of a body immersed in arc plasma flow. Consequently, the designed enthalpy probe can measure the wide ranges of plasma temperatures, velocities and concentrations simultaneously, which are generated by various types of arc heaters within the heat flux ranges of $0{\sim}5{\times}10^7\;W/m^2$ on the probe tip.