• Title/Summary/Keyword: plasma diagnosis

Search Result 352, Processing Time 0.024 seconds

Analysis of contaminated QMS, cleaning and restoration of functions (오염된 QMS의 원인 분석과 세정 및 기능 복원)

  • Kim, Donghoon;Joo, Junghoon
    • Journal of Surface Science and Engineering
    • /
    • v.48 no.4
    • /
    • pp.179-184
    • /
    • 2015
  • Quadrupole Mass Spectrometers (QMS) is a very useful tool in vacuum process diagnosis. Tungsten filament based ion sources are vulnerable to contamination from process gas monitoring. Common symptoms of quadrupole mass spectrometer malfunction is appearance of unwanted contaminant mass peaks or no detection of any ion peaks. We disassembled used quadrupole mass spectrometer and found out black insulating deposits on inside of ion source parts. Five steps of cleaning procedure were applied and almost full restoration of functions were confirmed in two types of closed ion source quadrupole mass spectrometer. By using a numerical modeling (CFD-ACE+) technique, the electric potential profile of ion source with/without insulating deposit was calculated and showed the possibility of quadrupole mass spectrometer malfunction by the deterioration of designed potential profile inside the ion source.

Properties of Electron Temperature and Electron Density in Inductively Coupled Xenon Plasma (유도결합형 제논 플라즈마의 전자온도, 전자밀도 특성)

  • Her, In-Sung;Choi, Gi-Seung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2418-2420
    • /
    • 2005
  • In this paper, parameters of electron temperature and density for the mercury-free lighting-source were measured to diagnosis and analyze in Xe based inductively coupled plasma(ICP). In results at several dependences of $20{\sim}100mTorr$ Xenon pressure, $50{\sim}200W$ RF power and horizontal distribution were especially mentioned. When Xe pressure was 20mTorr and RF power was 200W, the electron temperature and density were respectively 3.58eV and $3.56{\times}10^{12}cm^{-3}$. The key parameters of Xe based ICP depended on Xe pressure more than RF power that could be verified. A high electron temperature and low electron density with a suitable Xe pressure are indispensible parameters for Xe based ICP lighting-source.

  • PDF

Electrical and Optical properties of Xe gas in flat lighting source (제논(Xe) 가스를 사용한 평판형 광원에서의 전기 및 광학적 특성 연구)

  • Pack, Gwang-Hyeon;Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2190-2192
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Solitary plasmacytoma in the maxillary sinus: 10-year follow-up

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Sodnom-Ish, Buyanbileg;Cho, Yun Ju;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.6
    • /
    • pp.471-475
    • /
    • 2021
  • Solitary plasmacytoma (SP) is an uncommon form of plasma cell neoplasm occurring intraosseously or in soft tissue and presents as a single mass of monoclonal plasma cells. SP in the maxillary sinus is rare and can be misdiagnosed as other maxillary sinus tumors. The essential examinations in patients with the initial diagnosis of plasmacytoma are bone marrow biopsy, serum and urine electrophoresis, and kappa/lambda ratio (κ:λ ratio) to rule out multiple myeloma (MM). Herein, a rare case of SP in the maxillary sinus treated by surgery and localized radiation is reported. At the 10-year follow-up examination, local recurrence or disseminated development of MM were not evident.

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

Mucolipidosis Type II in Vietnam

  • Vu, Chi Dung
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.2 no.1
    • /
    • pp.31-31
    • /
    • 2016
  • Purpose: To describle clinical features and enzyme activity of Vietnamese patients with Mucolipidosis type II. Methods: Clinical features, laboratory and plasma lysosom enzyme activity by 4 MU-Fluorometric assay was studied from 2014-2015 at the Northern referral center of Pediatrics - National Children's Hospital. Results: 16 cases (7 girls and 9 boys) were diagnosed with I-cell bases on clinical symptoms and enzyme activities studies. Diagnosis age was $5.93{\pm}4.28$ years, onset age was recognised from birth to 4 years (median 1.25) with the feature of joint stiffness and bone deformation. All cases presented with the feature of joint stiffness, chest deformation and kyphoscoliosis; Fifteen cases (93.7%) had coarse facial features. No patients had hepatosplenomegaly on abdominal ultrasound, 5/15 patients had heart valves disease. Enzyme assay showed ${\alpha}$-Hexosaminidase of $1,885.9{\pm}338.7$ (nmol/mg plasma/17 hrs), ${\alpha}$-Iduronate sulfatase of $4,534.8{\pm}1,062.9nmol/mg$ plasma/4 hrs). Conclusion: Mucolipidosis II seriously affected the life of the patients with skeletal deformities, contractures develop in all joints and cardiac involvement.

Incipient Fault Detection of Reactive Ion Etching Process

  • Hong, Sang-Jeen;Park, Jae-Hyun;Han, Seung-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.262-271
    • /
    • 2005
  • In order to achieve timely and accurate fault detection of plasma etching process, neural network based time series modeling has been applied to reactive ion etching (RIE) using two different in-situ plasma-monitoring sensors called optical emission spectroscopy (OES) and residual gas analyzer (RGA). Four different subsystems of RIE (such as RF power, chamber pressure, and two gas flows) were considered as potential sources of fault, and multiple degrees of faults were tested. OES and RGA data were simultaneously collected while the etching of benzocyclobutene (BCB) in a $SF_6/O_2$ plasma was taking place. To simulate established TSNNs as incipient fault detectors, each TSNN was trained to learn the parameters at t, t+T, ... , and t+4T. This prediction scheme could effectively compensate run-time-delay (RTD) caused by data preprocessing and computation. Satisfying results are presented in this paper, and it turned out that OES is more sensitive to RF power and RGA is to chamber pressure and gas flows. Therefore, the combination of these two sensors is recommended for better fault detection, and they show a potential to the applications of not only incipient fault detection but also incipient real-time diagnosis.

The Electrical and Optical Properties of Xe Flat Plasma Light Source (제논 (Xe) 평판형 플라즈마 광원의 전기적 및 광학적 특성 연구)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup;Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.86-90
    • /
    • 2006
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the f1at lamp lighting source to understand property of lighting source is very important. Distance of discharge electrode is 5.5mm and width is 16.5mm, we have measured electron temperature and electron density measured with single Langmuir probe in flat lamp. We have tested the discharge from 100 Torr to 300 Torr pressure. The pulse is rectangular pulse with frequency 20kHz and duty ratio 20%. In result, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Study on the Effects of Ultrasonic Wave for the Effective Hydrogen Generation by Electrical Discharge Plasma Process

  • Park Jae-Youn;Cong Nghi-Vu;Han Sang-Bo;Kim Jong-Seok;Park Sang-Hyun;Lee Hyun-Woo;Lee Su-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.591-598
    • /
    • 2006
  • The research was tried to investigate the hydrogen generation from water by the pulsed power plasma process. Hydrogen was generated by way of the electrical pulse power discharge process with the ultrasonic wave. The yield on the hydrogen generation was also studied with and without operating the ultrasonic generator, in which the applied high voltage was varied from 10 kV to 15 kV. Nitrogen and argon gases were used as working gases. As the results, the generation yield using the pure nitrogen gas is better than argon and mixed gases such as argon and nitrogen. Hydrogen concentration are significantly increased when the ultrasonic generator was operated with the electrical discharge simultaneously. It is increased with increasing the applied ultrasonic level as well.

An overview of current knowledge about cell-free RNA in amniotic fluid

  • Jung, Yong Wook;Shin, Yun Jeong;Shim, Sung Han;Cha, Dong Hyun
    • Journal of Genetic Medicine
    • /
    • v.13 no.2
    • /
    • pp.65-71
    • /
    • 2016
  • Cell-free nucleic acids (cf-NAs) originate in trophoblasts and are detected in the maternal plasma. Using innovative bioinformatic technologies such as next-generation sequencing, cf-NAs in the maternal plasma have been rapidly applied in prenatal genetic screening for fetal aneuploidy. Amniotic fluid is a complex and dynamic fluid that provides growth factors and protection to the fetus. In 2001, the presence of cf-NA in amniotic fluid was reported. Amniotic fluid is in direct contact with the fetus and is derived from fetal urine and maternal and fetal plasma. Therefore, these genetic materials have been suggested to reflect fetal health and provide real-time genetic information regarding fetal development. Recently, several studies evaluated the global gene expression changes of amniotic fluid cell-free RNA according to gestational age. In addition, by analyzing the transcriptome in the amniotic fluid of fetal aneuploidy, potential key pathways and novel biomarkers for fetal chromosomal aneuploidy were identified. Here, we review the current knowledge of cell-free RNA in amniotic fluid and suggest future research directions.