• Title/Summary/Keyword: plasma application

Search Result 908, Processing Time 0.027 seconds

Verification of Optical Wireless Communication Functionality in Micro-LED Display Light Source Integrated with Field-effect Transistor (전계형 스위칭 소자가 집적된 마이크로 LED 디스플레이 광원의 광 무선 통신 기능 검증)

  • Jong-In Kim;Hyun-Sun Park;Pan-Ki Min;Myung-Jin Go;Young-Woo Kim;Jung-Hyun Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.2
    • /
    • pp.1-5
    • /
    • 2023
  • In the past, display devices have undergone many changes, such as plasma TVs and LCDs, and have continued to develop. Recently, new display technologies, such as Organic Light Emitting Diode displays and Inorganic Light Emitting Diode displays, have been developed. Among them, Micro LED displays have the potential to improve performance more than LCDs and OLEDs, but a lot of effort and time are needed until the mass production technology (transfer and bonding) of Micro LED displays is developed. We have developed a new Micro LED display light source that can be produced using existing transfer and bonding process technologies to enable faster commercialization of Micro LED in the industry. This light source is TFT deposition on LED. TFT deposition on LED has the advantage of being able to produce displays using existing process technology, making early commercialization of display application products possible. In this study, we applied the Active Driving method to verify the performance of TFT deposition on LED as a display to determine its commercialization potential. Additionally, to facilitate faster application of Micro LED in the industry, we applied TFT deposition on LED to Optical Wireless Communication systems, which are widely used in application service areas such as safety/security and sensors, to verify its communication performance. The experimental results confirmed that TFT deposition on LED is not only capable of AM driving but can also be applied to OWC systems.

  • PDF

Water Repellency on a Nanostructured Superhydrophobic Carbon Fibers Network

  • Ko, Tae-Jun;Her, Eun-Kyu;Shin, Bong-Su;Kim, Ho-Young;Lee, Kwang-Ryeol;Hong, Bo-Ki;Kim, Sae-Hoon;Oh, Kyu-Hwan;Moon, Myoung-Woon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.224-224
    • /
    • 2012
  • For decades, carbon fiber has expanded their application fields from reinforced composites to energy storage and transfer technologies such as electrodes for super-capacitors and lithium ion batteries and gas diffusion layers for proton exchange membrane fuel cell. Especially in fuel cell, water repellency of gas diffusion layer has become very important property for preventing flooding which is induced by condensed water could damage the fuel cell performance. In this work, we fabricated superhydrophobic network of carbon fiber with high aspect ratio hair-like nanostructure by preferential oxygen plasma etching. Superhydrophobic carbon fiber surfaces were achieved by hydrophobic material coating with a siloxane-based hydrocarbon film, which increased the water contact angle from $147^{\circ}$ to $163^{\circ}$ and decreased the contact angle hysteresis from $71^{\circ}$ to below $5^{\circ}$, sufficient to cause droplet roll-off from the surface in millimeter scale water droplet deposition test. Also, we have explored that the condensation behavior (nucleation and growth) of water droplet on the superhydrophobic carbon fiber were significantly retarded due to the high-aspect-ratio nanostructures under super-saturated vapor conditions. It is implied that superhydrophobic carbon fiber can provide a passage for vapor or gas flow in wet environments such as a gas diffusion layer requiring the effective water removal in the operation of proton exchange membrane fuel cell. Moreover, such nanostructuring of carbon-based materials can be extended to carbon fiber, carbon black or carbon films for applications as a cathode in lithium batteries or carbon fiber composites.

  • PDF

Improved Distribution of Threshold Switching Device by Reactive Nitrogen and Plasma Treatment (반응성 질소와 플라즈마 처리에 의한 문턱 스위칭 소자의 개선)

  • Kim, DongSik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.172-177
    • /
    • 2014
  • We present on a threshold switching device based on AsGeTeSi material which is significantly improved by two $N_2$ processes: reactive $N_2$ during deposition, and $N_2$ plasma hardening. The introduction of N2 in the two-step processing enables a stackable and thermally stable device structure, is allowing integration of switch and memory devices for application in nano scale array circuits. Despite of its good threshold switching characteristics, AsTeGeSi-based switches have had key issues with reliability at a high temperature to apply resistive memory. This is usually due to a change in a Te concentration. However, our chalconitride switches(AsTeGeSiN) show high temperature stability as well as high current density over $1.1{\times}10^7A/cm^2$ at $30{\times}30(nm^2)$ celll. A cycling performance of the switch was over $10^8$ times. In addition, we demonstrated a memory cell consisted of 1 switch-1 resistor (1S-1R) stack structure using a TaOx resistance memory with the AsTeGeSiN select device.

EFFECT OF GELATIN SPONGY AND PLATELET RICH PLASMA ON RIDGE PRESERVATION AND BONE FORMATION AFTER EXTRACTION (발치 후 젤라틴 스폰지와 혈소판 농축 혈장이 치조제 보존 및 골 형성에 미치는 영향)

  • Kim, Young-Seok;Kwon, Kyung-Hwan;Cha, Soo-Yean;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.238-247
    • /
    • 2005
  • The placement of different graft materials and/or the use of occlusive membranes to cover the extraction socket entrance are techniques aimed at reducing alveolar ridge resorption and enhancing bone formation. However, in spite of its clinical advantage, the use of graft materials in fresh extraction socket has been questioned because particles of the grafted material have been found in alveolar sockets with fibrous union. The purposes of this study were to evaluate whether alveolar ridge resorption following tooth extraction could be reduced and bone formation could be enhanced by the application of absorbable gelatin spongy or gelatin spongy soaked with platelet rich plasma(PRP) used as a space filler in clinical and radiographic aspects. Eighty patients who were scheduled for extraction of both third molars were participated and carried out by one experienced surgeon. Following extraction of teeth, one extracted socket were treated with gelatin spongy as an experimental group A and the other were treated with gelatin spongy and PRP as an experimental group B. The routine extracted socket were healed without any treatment as a control group. From the period of extraction to 12 weeks postoperatively, we examined the clinical course and radiographic evaluation on socket at regular interval. Both experimental groups showed faster wound healing process than control clinically. Vertical gingival height of the extraction socket were less changed statistically in both experimental groups than control. The horizontal width change of the extraction socket were not significant statistically in any group. Radiographic changes of the alveolar bone height were less changed in both experimental groups and bone density were showed higher than control. There were a little difference between experimental group A and B. In conclusion, absorbable gelatin sponge and with PRP were considered as having preservation effects of extraction socket and stimulation of bone formation process after extraction.

Effects of Chromium Supplementation and Lipopolysaccharide Injection on the Immune Responses of Weanling Pigs

  • Lee, D.N.;Shen, T.F.;Yen, H.T.;Weng, C.F.;Chen, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.10
    • /
    • pp.1414-1421
    • /
    • 2000
  • Sixteen specific pathogen free 4-wk-old crossbred weanling pigs were allotted into a $2{\times}2$ factorial experiment to evaluate the effects of chromium (Cr) on the immune responses after lipopolysaccharide (LPS) injection. Two factors included (1) no Cr or 400 ppb Cr supplementation from chromium picolinate (CrPic) and (2) LPS injection ($200{\mu}g/kg$ BW, intraperitoneally) on day 21 (d 21) and 35 (d 35) as compared with saline application. Plasma samples were obtained from all piglets before (0 h) and at 2 h, 4 h, 8 h, and 24 h after LPS injection. The changes in tumor necrosis $factor-{\alpha}$ ($TNF-{\alpha}$) and leukocyte populations after LPS injection were not significant on d 21. On d 35, the plasma $TNF-{\alpha}$ level was increased at h 2 postinjection, and supplemental Cr reduced the $TNF-{\alpha}$ level. The leukocyte populations had changed profoundly and lymphocyte subsets of $CD2^+$ and $CD8^+$ were reduced at 8 h postinjection. The blood granulocytes were increased and the percentage of $CD2^+$ was reduced in the Cr-fed group on d 35. Furthermore, Cr supplementation decreased the blastogensis of concanavalin A-stimulated peripheral blood mononuclear cells (PBMC) on d 21. These results suggest that 400 ppb Cr supplementation from CrPic in diets may modulate the immune responses in weanling pigs during LPS injection.

Bridgeless High Efficiency ZVZCS Power Factor Correction Circuit for PDP Power Module (PDP 파워 모듈을 위한 브리지 없는 고효율 ZVZCS 역률개선회로)

  • Ryu Byung-Gyu;Moon Gun-Woo;Cho Kyu-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.226-232
    • /
    • 2005
  • Recently, many nation have released standard such as IEC 61000-3-2 and IEEE 59, which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC Line. Therefore, Plasma Display Panel(PDP) which is highlightened in digital display device also has the Power Factor Correction(PFC) circuit to meet the harmonic requirements. In PDP power module, the conventional boost converter is usually used for the PFC circuit. However, it comes serious thermal problem on it's bridge diode due to heat of PDP, and therefore the system stability is not guaranteed. In this paper, the bridgeless boost converter, which is used for PFC circuit of the PDP power module, is designed and verified the possibility of the application In a practical product in a view of efficiency, component count, temperature and etc.

Transport of Some Solutes in Blood Plasma Through Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane (혈장내 염의 Poly(2-Hydroxyethyl Methacrylate) 격막 투과현상)

  • Jee Jong Gi;Jhon Mu Shik;Ree Tai Kyue
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.5
    • /
    • pp.304-310
    • /
    • 1978
  • The relative permeabilities, distribution coefficients and diffusion coefficient of some salts which are important components in blood plasma through a poly(HEMA) membrane were measured. The crosslinker which was used for preparing the membrane was tetraethylene glycol dimethacrylate(TEGDMA), the weight percentage of the latter was about 2.8. We found that the diffusion coefficients ($D_m$) of the solutes decrease exponentially with increasing molecular weight, and also that $D_m$'s decrease linearly (except urea) with cylindrical radius (a). These facts were explained by a sieve pore flow model. The relative permeability and diffusion coefficient of urea at various temperature were larger than those of other solutes such as glycine, ${\beta}$-alanine, D-glucose, saccharose and maleic acid. The result indicates that the poly(HEMA) membrane might be suitable for hemodialysis application.

  • PDF

The Leaves of Broussonetia kazinoki Siebold Inhibit Atopic Dermatitis-Like Response on Mite Allergen-Treated Nc/Nga Mice

  • Lee, Hoyoung;Ha, Hyekyung;Lee, Jun Kyoung;Park, Sang-Joon;Jeong, Seung-Il;Shin, Hyeun Kyoo
    • Biomolecules & Therapeutics
    • /
    • v.22 no.5
    • /
    • pp.438-444
    • /
    • 2014
  • Broussonetia kazinoki Siebold. (B. kazinoki) has long been used in the manufacture of paper in Asian countries. Although B. kazinoki leaves (BK) have been employed in dermatological therapy, use of BK has not been tested in patients with atopic dermatitis (AD). Using Nc/Nga mice, which are genetically predisposed to develop AD-like skin lesions, we confirmed the efficacy of BK in AD treatment. BK extract was applied topically to Dermatophagoides farinae-induced AD-like lesions in Nc/Nga mice, and the effects were assessed both clinically and by measuring skin thickness on the back and ears. We measured the effects of BK extract on plasma levels of IgE and IL-4. We also measured the ability of BK extract to inhibit the secretion of hTARC in HaCaT cells after stimulation by TNF-${\alpha}$ and IFN-${\gamma}$. We found that BK extract significantly reduced ear and dorsal skin thickness and the clinical signs of AD, as well as significantly down-regulating the plasma levels of IgE and IL-4 (p<0.01 for each comparison). Moreover, $500{\mu}g/mL$ of BK extract inhibited hTARC secretion in HaCaT cells by activated TNF-${\alpha}$/IFN-${\gamma}$ by about 87%. These findings suggest that topical application of BK extract has excellent potential in the treatment of AD.

Effects of PEO Conditions on Surface Properties of AZ91 Mg Alloy (PEO 처리조건에 따른 마그네슘 합금 AZ91의 표면특성변화에 관한 연구)

  • Park, Kyeong-Jin;Jung, Myung-Won;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.71-77
    • /
    • 2010
  • Mg alloys have been used in automobile industry, aerospace, mobile phone and computer parts owing to low density. However, they have a restricted application because of low mechanical and poor corrosion properties. Thus, improved surface treatments are required to produce protective films. Environmental friendly Plasma Electrolytic Oxidation(PEO) was used to produce protective films on magnesium alloys. PEO process is combined electrochemical oxidation with plasma treatment in the aqueous solution. In this study, the effects of applied voltage and applied current on the surface morphologies were investigated. Also, the effects of Direct Current(DC) and Pulse Current(PC) were compared. PC and constant current control gave the dense coating on the Mg alloy. The potentiodynamic polarization tests were carried out for the analysis of corrosion properties of specimens. The surface hardness was 5 times higher than that of untreated AZ91D.

Clinical Outcomes of Percutaneous Plasma Disc Coagulation Therapy for Lumbar Herniated Disc Diseases

  • Kim, Sang-Hyun;Kim, Sung-Chul;Cho, Ki-Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Objective : This is prospective study of clinical outcomes of percutaneous plasma disc coagulation Therapy (PDCT) in patients with herniated lumbar disc disease (HLD) to evaluate the safety and efficacy in its clinical application and usefulness as a reliable alternative to microscopic discectomy. Methods : Forty-six patients were enrolled in this study from April 2006 to June 2010. All patients had one-level HLD. Disc degeneration was graded on routine T2-weighted magnetic resonance Image (MRI) using the Pfirrmann's grading system and all index levels were grade 3 and grade 4. Indications for surgery were radiculopathy caused by disc protrusion with soft consistency. MRI was done at one month after the procedure in all patients to check post-PDCT change. The clinical outcomes were evaluated using Visual Analog Scales (VAS) score and MacNab's criteria. Results : This study was approved by the Institutional Review Board of our institution. The age of the study population ranged from 16 to 59 years with a mean age of 37.2 years. There were 29 males and 17 females in this study. The mean period of clinical follow-up was 21 months. The average preoperative VAS score for radiculopathy was $7.4{\pm}1.4$, while the final follow-up VAS score was $1.4{\pm}0.7$ (p<0.001). In MacNab's criteria, 41 patients (89.1%) had achieved favorable improvement (excellent and good) until later follow-up. There were one patient from infection and two patients who needed to convert to open discectomy. Conclusion : PDCT is a safe and efficient treatment modality in a selective patient with HLD.