• Title/Summary/Keyword: plasma application

Search Result 908, Processing Time 0.036 seconds

Tribological Properties of DLC for Die Applications

  • Lee, Kyu-Yong;Liu, Zhen-Hua
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.24-28
    • /
    • 2012
  • Friction and wear affect all processes involved in the extraction of materials and their conversion into finished products in the die applications such as drawing, extrusion etc. Originating phenomenon from the contact surface between the tool and workpiece, they are usually a hindrance to materials process operations which usually result in damaging the tools, increasing energy consumption, the contamination of processed material by wear particles and also some problems associated with technologies to control friction and wear. The most well established method to control friction and wear is by the application of lubricant such as fluorocarbon. Besides, a surface technique so-called surface modification can be applied to solve the tribology problems of the die applications for both the economical and ecological reasons. In this article, we applied DLC(diamond-like carbon) thin film on alumina ceramic for HT test using the PIID(plasma ion immersion deposition), 4 groups of test specimens were tested up to $200^{\circ}C$ which is a little higher than the normal working temperature of die application. Pin-on-disc tribo-tester was used to test the friction and surfaces were characterized by SEM and EDS and else, the morphology changes of DLC coatings were studied. The present work indicated that the DLC had a great potential to reduce the friction and wear in the alumina die application without lubricants.

  • PDF

Effects of Preemptive Analgesia with Parecoxib Sodium on Haemodynamics and Plasma Stress Hormones in Surgical Patients with Thyroid Carcinoma

  • Wang, Lian-Dong;Gao, Xia;Li, Jun-Ying;Yu, Hong-Yan;Su, Hai-Wen;Liu, Lian-Zhong;Qi, Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3977-3980
    • /
    • 2015
  • Background: To investigate the effects of preemptive analgesia with parecoxib sodium on haemodynamics and plasma stress hormones in surgical patients with thyroid carcinoma. Materials and Methods: Fifty-seven patients with thyroid carcinoma who underwent thyroidectomy selectively in Laiwu Hospital Affiliated to Taishan Medical University and Binzhou People's Hospital were selected and randomly divided into three groups, 19 cases in each group. The control group was intravenously injected 0.9% sodium chloride injection before anesthesia induction; trial group I was intravenously injected with parecoxib sodium 20 min before anesthesia induction; based on trial group I, trial group II was injected with parecoxib sodium again 12 h after surgery. The levels of plasma norepinephrine (NE), cortisol (Cor) and blood glucose before, 12 and 24 h after surgery and changes of haemodynamics before surgery, at the end of surgery and 12, 24 and 48 h after surgery were compared in the three groups. Besides, visual analogue scale (VAS) scores were recorded 4, 8, 12 and 24 h after surgery. Results: 12 and 24 h after surgery, the levels of plasma NE and Cor in three groups rose dramatically (P<0.05 or (P<0.01); The levels of plasma NE and Cor in trial groups I and II were evidently lower than in control group (P<0.05 or P<0.01), and those in trial group II slightly lower than in trial group I. 12 h after surgery, the heart rates (HR) and systolic pressures (SBP) in trial groups I and II increased obviously by comparison to surgery before (P<0.05 or P<0.01), but gradually returned to the preoperative level. HR, SBP and diastolic pressures (DBP) in trial groups I and II at the end of surgery and 12 h after surgery were all lower than in the control group, and significant differences were present (P<0.05 or (P<0.01). At 4, 8, 12 and 24 h after surgery, VAS scores in trial groups I and II were markedly lower than in the control group (P<0.05 or (P<0.01), the scores in trial group II being the lowest. Conclusions: Combined application of parecoxib sodium for preemptive analgesia before anesthesia and after surgery can effectively reduce the levels of plasma stress hormones and improve analgesic effects in surgical patients with thyroid carcinoma, and without conspicuous impact on haemodynamics.

Development of Large-area Plasma Sources for Solar Cell and Display Panel Device Manufacturing

  • Seo, Sang-Hun;Lee, Yun-Seong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.148-148
    • /
    • 2011
  • Recently, there have been many research activities to develop the large-area plasma source, which is able to generate the high-density plasma with relatively good uniformity, for the plasma processing in the thin-film solar cell and display panel industries. The large-area CCP sources have been applied to the PECVD process as well as the etching. Especially, the PECVD processes for the depositions of various films such as a-Si:H, ${\mu}c$-Si:H, Si3N4, and SiO2 take a significant portion of processes. In order to achieve higher deposition rate (DR), good uniformity in large-area reactor, and good film quality (low defect density, high film strength, etc.), the application of VHF (>40 MHz) CCP is indispensible. However, the electromagnetic wave effect in the VHF CCP becomes an issue to resolve for the achievement of good uniformity of plasma and film. Here, we propose a new electrode as part of a method to resolve the standing wave effect in the large-area VHF CCP. The electrode is split up a series of strip-type electrodes and the strip-type electrodes and the ground ones are arranged by turns. The standing wave effect in the longitudinal direction of the strip-type electrode is reduced by using the multi-feeding method of VHF power and the uniformity in the transverse direction of the electrodes is achieved by controlling the gas flow and the gap length between the powered electrodes and the substrate. Also, we provide the process results for the growths of the a-Si:H and the ${\mu}c$-Si:H films. The high DR (2.4 nm/s for a-Si:H film and 1.5 nm/s for the ${\mu}c$-Si:H film), the controllable crystallinity (~70%) for the ${\mu}c$-Si:H film, and the relatively good uniformity (1% for a-Si:H film and 7% for the ${\mu}c$-Si:H film) can be obtained at the high frequency of 40 MHz in the large-area discharge (280 mm${\times}$540 mm). Finally, we will discuss the issues in expanding the multi-electrode to the 8G class large-area plasma processing (2.2 m${\times}$2.4 m) and in improving the process efficiency.

  • PDF

Ridge Formation by Dry-Etching of Pd and AlGaN/GaN Superlattice for the Fabrication of GaN Blue Laser Diodes

  • Kim, Jae-Gwan;Lee, Dong-Min;Park, Min-Ju;Hwang, Seong-Ju;Lee, Seong-Nam;Gwak, Jun-Seop;Lee, Ji-Myeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.391-392
    • /
    • 2012
  • In these days, the desire for the precise and tiny displays in mobile application has been increased strongly. Currently, laser displays ranging from large-size laser TV to mobile projectors, are commercially available or due to appear on the market [1]. In order to achieve a mobile projectors, the semiconductor laser diodes should be used as a laser source due to their size and weight. In this presentation, the continuous etch characteristics of Pd and AlGaN/GaN superlattice for the fabrication of blue laser diodes were investigated by using inductively coupled $CHF_3$ and $Cl_2$ -based plasma. The GaN laser diode samples were grown on the sapphire (0001) substrate using a metal organic chemical vapor deposition system. A Si-doped GaN layer was grown on the substrate, followed by growth of LD structures, including the active layers of InGaN/GaN quantum well and barriers layer, as shown in other literature [2], and the palladium was used as a p-type ohmic contact metal. The etch rate of AlGaN/GaN superlattice (2.5/2.5 nm for 100 periods) and n-GaN by using $Cl_2$ (90%)/Ar (10%) and $Cl_2$ (50%)/$CHF_3$ (50%) plasma chemistry, respectively. While when the $Cl_2$/Ar plasma were used, the etch rate of AlGaN/GaN superlattice shows a similar etch rate as that of n-GaN, the $Cl_2/CHF_3$ plasma shows decreased etch rate, compared with that of $Cl_2$/Ar plasma, especially for AlGaN/GaN superlattice. Furthermore, it was also found that the Pd which is deposited on top of the superlattice couldn't be etched with $Cl_2$/Ar plasma. It was indicating that the etching step should be separated into 2 steps for the Pd etching and the superlattice etching, respectively. The etched surface of stacked Pd/superlattice as a result of 2-step etching process including Pd etching ($Cl_2/CHF_3$) and SLs ($Cl_2$/Ar) etching, respectively. EDX results shows that the etched surface is a GaN waveguide free from the Al, indicating the SLs were fully removed by etching. Furthermore, the optical and electrical properties will be also investigated in this presentation. In summary, Pd/AlGaN/GaN SLs were successfully etched exploiting noble 2-step etching processes.

  • PDF

Optimum design analysis of ICP(Inductively Coupled Plasma) torch for high enthalpy thermal plasma flow (고엔탈피 열유동 발생용 고주파 유도결합 플라즈마 토치의 최적 설계변수 해석)

  • Seo, Jun-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.316-329
    • /
    • 2012
  • In this paper, optimum design process of ICP (Inductively Coupled Plasma) torch, which has been used widely in aerospace application, such as supersonic plasma wind tunnel, is presented. For this purpose, the behaviors of equivalent circuit parameters (equivalent resistance and inductance, coupling efficiency) were investigated according to the variations of torch design parameters (frequency, $f$, confinement tube radius, $R$ and coil turn numbers, $N$) in the basis of analytical and numerical MHD (Magneto Hydro-Dynamics) models combined with electrical circuit theory. From the results, it is found that equivalent resistance is increased with the increase of $f$ values but vice versa for equivalent inductance. For elevated values of $R$ and $N$, however, both parameters tend to increase. Based on these observations, ICP torch with a power level of 10 kW can be optimized at the design ranges of $f$=4~6 MHz, $R$=17~25 mm and $N$=3~4 to maximize the electrical coupling efficiency, which is the ratio of equivalent resistance to equivalent inductance.

Hydrogen Production for PEMFC Application in Plasma Reforming System (PEMFC용 플라즈마 개질 시스템의 수소 생산)

  • Yang, Yoon Cheol;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.1002-1007
    • /
    • 2008
  • The purpose of this paper studied the optimal hydrogen production condition of plasma reforming system to operate the PEMFC. Plasma reforming reactor used with Ni catalyst reactor at the same time, So $H_2$ concentration increased. Also the WGS and PrOx reactor were designed to remove CO concentration under 10 ppm, because CO has effect on catalyst poisoning of PEMFC. The maximum $H_2$ production condition in plasma reforming system was S/C ratio 3.2, $CH_4$ flow rate 2.0 L/min, catalytic reactor temperature $700{\pm}5^{\circ}C$ and input power 900 W. At this time, the concentration of produced syngas was $H_2$ 70.2%, CO 7.5%, $CO_2$ 16.2%,$CH_4$ 1.8%. The hydrogen yield, hydrogen selectivity and $CH_4$ conversion rate were 56.8%, 38.1% and 92.2% respectively. The energy efficiency and specific energy requirement were 37.0%, 183.6 kJ/mol. In additional, The experiment of $CO_2/CH_4$ ratio proceeded. Also WGS reactor experiment was proceeding on optimum condition of plasma reactor and the exit concentration were $H_2$ 68%, CO 337 ppm, $CO_2$ 24.0%, $CH_4$ 2.2%, $C_2H_4$ 0.4%, $C_2H_6$ 4.1%. At this time, experiment result of PrOx reactor were $H_2$ 51.9%, CO 0%, $CO_2$ 17.3%.

A Nucleic Acid Amplification Tests for Reliable HCV RNA Detection Method for Plasma-Derived Products (핵산증폭시험을 이용한 혈장분획물질에서 HCV RNA 검출)

  • Hong, Seung-Hee
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.293-298
    • /
    • 2008
  • HCV is transmitted via various plasma derived products. Current methods to detect hepatitis C virus (HCV) are based on its antibody detection in the donated blood and plasma. Viral contamination can potentially escape such detection during the window period of infection, when no antibody is present or the level of antibody is too low to detect. It is trying to application of nucleic acid amplification tests (NAT) for the direct detection of HCV. The objective of this study was to develop a reliable NAT for the HCV RNA detection from plasma-derived products. The most useful primers was selected for NAT among 5 sets of primers. We have also found that QIAamp viral RNA isolation kit was the most efficient for HCV RNA isolation. The highest sensitivity and specificity was appeared in $48^{\circ}C$ annealing temperature and 30 pmol of primers. With a spiking of HCV to albumin, immunoglobulins and coagulation factors, NAT can detect up to 100 IU/ml. Meanwhile, COBAS amplicor HCV 2.0 afforded a lower sensitivity in high concentrated intramuscular immunoglobulins to below 500 IU/ml. Our results suggested that NAT appears to be a highly sensitive and specific method for HCV RNA detection in plasma-derived products.

GENERATION OF MAGNETIC FIELDS BY TEMPERATURE GRADIENTS

  • OKABE NOBUHIRO;HATTORI MAKOTO
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.547-551
    • /
    • 2004
  • We showed that magnetic fields are generated in the plasma which have the temperature inhomogeneities. The mechanism is the same as the Weibel instability because the velocity distribution functions are at non-equilibrium and anisotropic under the temperature gradients. The growth timescale is much shorter than the dynamical time of structure formation. The coherence length of magnetic fields at the saturated time is much shorter than kpc scale and then, at nonlinear phase, become longer by inverse-cascade process. We report the application of our results to clusters of galaxies, not including hydrodynamic effects.