Citizen's Attitude to Environmental Facilities (환경기초시설에 대한 시민 의식 조사)

  • Chung, Jae-Chun;Chung, Won-Tae;Tak, Seung-Je;Kang, Hun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • A questionare survey was performed to investigate the citizen's attitude concerning waste treatment facilities. Most people recognized the seriousness of the waste treatment problem and think that more composting facilities should be built. People dislike most the landfill facility, followed by the nightsoil treatment facility, the incineration facility and the composting facility. Most people answered that the disirable distance from their house to the treatment facility should be farther than 4km for the landfill facility, farther than 2km for incineration and composting facilities and farther than 1km for the wastewater treatment plant. Most people want moving cost+land price+inconvience suffering cost (amount equal to the land prize+building prize) for their retrieval. About 30% of people answered that they will not accept any waste treatment facility even though it is perfect.

  • PDF

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

Analysis of UV Filters in Water using Stir Bar Sorptive Extraction (SBSE) and GC/MS-MS (교반막대 추출법과 GC/MS-MS를 이용한 수중의 자외선 차단제 분석)

  • Seo, Chang-Dong;Son, Hee-Jong;Jung, Jong-Moon;Choi, Jin-Taek;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1037-1047
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC/MS-MS) has been developed, allowing the simultaneous multi-analyte determination of seven UV filters in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 12.9%). The extraction efficiencies were above 84% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~8.6 ng/L and 6.8~27.5 ng/L, respectively. The developed method offers the ability to detect 8 UV filters at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 7 UV filters except of benzophenone (BP). The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.

Piggery Waste Treatment using Partial Nitritation and Anaerobic Ammonium Oxidation (부분질산화와 혐기성 암모늄산화를 이용한 돈사폐수처리)

  • Hwang, In-Su;Min, Kyung-Sok;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.599-604
    • /
    • 2006
  • Nitrogen removal with the combined SHARON (Single reactor system for high ammonium removal over nitrite)ANAMMOX (Anaerobic ammonium oxidation) process using the effluent of ADEPT (Anaerobic digestion elutriated phased treatment) slurry reactor with very low C/N ratio for piggery waste treatment was investigated. For the preceding SHARON reactor, ammonium nitrogen loading and removal rate were $0.97kg\;NH_4-N/m^3_{reactor}/day$ and $0.68kg\;NH_4-N/m^3_{reactor}/day$ respectively. In steady state, bicarbonate alkalinity consumption for ammonium nitrogen converted to $NO_2-N$ or $NO_3-N$ was 8.4 gram per gram ammonium nitrogen. The successive ANAMMOX reactor was fed with the effluent from SHARON reactor. The loading and removal rate of the soluble nitrogen defined as the sum total of $NH_4-N$, $NO_2-N$ and $NO_3-N$ in ANAMMOX reactor were $1.36kg\;soluble\;N/m^3_{reactor}/day$ and $0.7kg\;soluble\;N/m^3_{reactor}/day$, respectively. The average $NO_2-N/NH_4-N$ removal ratio by ANAMMOX was 2.41. Fluorescence in situ hybridization (FISH) analysis verified that Candidatus Kuenenia stuttgartiensis were dominate, which means that they played an important role of nitrogen removal in ANAMMOX reactor.

State Evaluation of Nutrient Removal in an Intermittent Aeration Process by Monitoring ORP & pH (ORP와 pH 측정에 의한 간헐폭기 고도처리 공정 제어의 평가)

  • Ko, Kwang Baik;Suh, Jun Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.401-409
    • /
    • 2002
  • In this study, to evaluate the applicability of ORP and pH as process control parameters for an intermittent aeration process, a 200L/d bench-scale plant was installed and operated for 90 days. It was fed with synthetic wastewater which contained $COD_{Cr}$ : 400mg/L, TN : 40mg/L and TP : 7mg/L. ORP & pH were measured on-line and compared with the variation of nutrient concentrations. As the results, both of the ORP and pH were able to monitor successfully nitrification and denitrification. Bending-points on the ORP curve and peak points on the pH curve corresponded to the termination of nitrification and denitrification. For P uptake and release, pH was the best indicator for performance evaluation. The aerobic pH apex was appeared when P uptake was accomplished and there was a relationship between the P release and pH variation. But the pH curve needed filtering because there were many noises on it. In this study, the shape of the ORP & pH curves were varied as the operating conditions such as aeration rates and organic loads were changed. It allowed the operating states of biological systems to be effectively evaluated. If it is properly managed to show the bending points and peak points clearly, the on-line monitoring of ORP & pH will be a reliable and effective technique for process control of intermittent aeration processes.

THE EFFECTS OF OPERATIONAL AND FINANCIAL FACTORS ON THE ECONOMICS OF BIOGAS PRODUCTION FROM DAIRY COW FECES AND WASTEWATER

  • Kobayashi, S.;Masuda, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.1
    • /
    • pp.139-145
    • /
    • 1993
  • Biogas created from animal waste is a precious energy source. A practical and successful utilization of the biogas is not easy, because there lie some difficulties in biogas production and facilities investment. In this study, the requisites for a successful biogas utilization were discussed. The production results obtained in the previous operation of anaerobic digestion plant were used for the simulation. When the slurry heating was designed for constant biogas generation, depreciation costs of the facilities amounted 1,175,000 yen per year, and biogas productions at $24.5^{\circ}C$, $30.0^{\circ}C$ and $35.5^{\circ}C$ were $16.8m^3$, $17.6m^3$ and $25.1m^3$, respectively. Removal ratios of organic matters were not so high. At $35.5^{\circ}C$, energy value of the biogas produced was estimated 125.5 Mcal per day, and the following heat loss (y Mcal/day) was brought about by the temperature difference ($X^{\circ}C$) between the digester and atmosphere; y = 0.769X - 5.375. The costs of biogas production per cow were assumed to decrease according to enlargement of feeding scale, especially on scales of more than 30 cows. On recent levels of costs and prices of energy in Japan, they were nearly equal to 2 to 3 fold of the price of municipal mixed gas when a anaerobic digester was compulsorily heated and kept at $30.0^{\circ}C$ or $35.5^{\circ}C$.

침지형 분리막을 사용한 오수처리

  • 최광호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.113-133
    • /
    • 1998
  • In activated sludge process, sludge settling condition is affected by organic loading rate or operation condition, and if settling condition is getting worse, it is common that overall process fails due to wash-out of biomass causing low concentration in the aeration tank. Also activated sludge process has such several problems as requiring large area, consuming a lot of power and producing large volume of sludge. Increased public concern over health and the environment combined with a strong desire to reduce capital, operating and maintenance costs, have created a need for innovative technologies for building new high quality effluents which vail meet 21st century crkeria. MBR(Membrane Bioreactor) process consists of a biological reactor and ultrafiltration(UF) membrane system that replaces the conventional clarifier of an activated sludge process. The main operating advantages of this system are that the quality of the effluent is independent of the settleability of the mixed liquor and that the effluent is free of suspended solids in any operating condition. It is possible to eliminate clarifier and to reduce the volume of aeration tank because it can afford to accumulate high biomass concentration in the bioreactor(20, 000~30, 000mg/L), which would not be possible in a conventional activated sludge process. Therefore, this process reduces overall treatment plant area. In addition to those advantages, Longer SRT condition enables higher sludge digestion in MBR process so the sludge volume produced is 50 to 70% lower than that of conventional activated sludge process There are two kinds of MBR process according to the allocations of membrane. One is cross flow type MBR of which module is located outside of the bioreactor and mixed liquor is driven into the membrane module. The other is submerged type MBR process of which module is submerged in the bioreactor and mixed liquor is generally sucked from the lumen side. addition to that the cake layer is often removed by the uplifting flow of bubbling air. A submerged MBR process is superior to a crossflow MBR in regard to the power consumption because suction pressure of a submerged MBR is generally lower than that of a crossflow MBR which has recirculation pump. A submerged MBR, therefore, has the potential to be applied to small wastewater treatment plants that need low cost treatment systems.

  • PDF

A report of 28 unrecorded bacterial species, phylum Bacteroidetes, in Korea

  • Maeng, Soohyun;Baek, Chaeyun;Bae, Jin-Woo;Cha, Chang-Jun;Jahng, Kwang-Yeop;Joh, Ki-seong;Kim, Wonyong;Seong, Chi Nam;Lee, Soon Dong;Cho, Jang-Cheon;Yi, Hana
    • Journal of Species Research
    • /
    • v.7 no.2
    • /
    • pp.104-113
    • /
    • 2018
  • In order to investigate indigenous prokaryotic species diversity in Korea, various environmental samples from diverse ecosystems were examined. Isolated bacterial strains were identified based on 16S rRNA gene sequences, and those exhibiting at least 98.7% sequence similarity with known bacterial species, but not reported in Korea, were selected as unrecorded species. 28 unrecorded bacterial species belonging to the phylum Bacteroidetes were discovered from various habitats including wastewater, freshwater, freshwater sediment, wet land, reclaimed land, plant root, bird feces, seawater, sea sand, tidal flat sediment, a scallop, marine algae, and seaweed. The unrecorded species were assigned to 18 different genera in five families: Flavobacterium, Epilithonimonas, Dokdonia, Gillisia, Flavicella, Chryseobacterium, Algibacter, Aquimarina, Lacinutrix, Gaetbulibacter, Cellulophaga, Tenacibaculum, and Maribacter of Flavobacteriaceae, Dyadobacter of Cytophagaceae, Draconibacterium of Draconibacterium_f, Sunxiuqinia of Prolixibacteraceae, and Fulvivirga of Fulvivirga_f. The selected isolates were subjected to further taxonomic characterization including analysis of Gram reaction, cellular and colonial morphology, biochemical activities, and phylogenetic trees. Descriptive information of the 28 unrecorded species is provided.

Evaluation of Water Quality Goal and Load Allocation Achievement Ratio in Guem River Total Maximum Daily Loads for the 1st Phase (금강수계 1단계 수질오염총량관리제의 목표수질 및 할당부하량 달성도 평가)

  • Park, Jae Hong;Oh, Seung Young;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.859-865
    • /
    • 2012
  • It is necessary to evaluate performances hitherto carried out in the management of Total Maximum Daily Loads (TMDLs) and to set up direction so that this system can be improved continuously in the future. This study was investigated load allocation achievement ratio, water quality goal achievement ratio and interrelation between water quality goal and load allocation for the first period (2004~2010). Load allocation achievement and BOD water quality goal achievement ratio were 50% and 73% in Guem River Basin, respectively. The main reason for excess of load allocation and shortfall of water quality goal were unfulfilled reduction plan and pollution sources increment. Therefore, it is necessary to develop enhanced pollution sources prediction method and make a list realizable reduction plan. 63% of the unit watershed was not interrelation between water quality goal and load allocation. The reason why water quality goal and load allocation had not correlation were water quality of upper unit watershed, increment of inflow quantity, effluent water quality of wastewater treatment plant affected the unit watershed, increment of inner productivity by algae, water quality deterioration during the specific period, river management flow, etc.

Analysis of Dominant Microorganisms of Bulking Sludge at Low Dissolved Oxygen Concentration using 16S rRNA Sequences (16S rRNA 염기서열을 이용한 낮은 용존산소농도에서 발생한 벌킹슬러지의 우점종 분석)

  • Kim, Yun-Jung;Park, Eun-Hye;Kim, Gyu-Dong;Nam, Kyoungphile;Chung, Tai Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.506-511
    • /
    • 2004
  • Maintaining dissolved oxygen (DO) at sufficiently low concentration in the aeration tank at a wastewater treatment plant (WWTP) is essential for reduction of the costs of operation and maintenance. On the other hand, the low DO level may result in adverse effect on the integrity of the activated sludge, A typical and disastrous outcome frequently experienced is the outgrowth of filamentous microorganisms, which is called as filamentous bulking, In addition to the traditional methods such as sludge settleability and microscopic observation of the culture, molecular techniques including polymerase chain reaction (PCR) amplification followed by 16S rRNA sequencing were applied to identify filamentous bacteria present in bulking sludge under a condition of low DO concentration, Two morphologically distinct groups, presumably consisting of Sphaerofilus nafans, and Eikelboom Type 1701 or Type 1851, were identified through microscopic observation. They were further confirmed by subsequent 16S rRNA sequencing. Dominant filamentous bacteria identified by the molecular techniques were consisted of three major groups. Sequences of partial 16S rRNA cloned showed that the filamentous bulking organisms were closely related to Eikelboom Type 021N and Eikelboom Type 1701, and Sphaerotilus natans, respectively. Molecular methods were found to possess a strong potential of direct examination of the microbial community of an activated sludge system.