• Title/Summary/Keyword: plant construction

Search Result 2,247, Processing Time 0.032 seconds

The Study of Optimized Combustion Tuning for Fossil Power Plant (발전보일러의 최적연소조정에 대한 실험적 연구)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.102-108
    • /
    • 2009
  • Fossil power plants firing lower grade coals or equipped with modified system for NOx controls are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. In order to develop a on-line combustion tuning system, field test was conducted at operating power boiler. During the field test the exhaust gases' $O_2$, NOx and CO was monitored by using a spatially distributed monitoring grid located in the boiler's high temperature vestibule and upper convective back-pass region. At these locations, the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. using these monitored information we can improving combustion at every point within the furnace, therefore the boiler can operate at reduced excess $O_2$ and gas temperature deviation, reduced furnace exit gas temperature levels while also reducing localized hot spots, corrosive gas conditions, slag or clinker formation and UBC. Benefits include improving efficiency, reducing NOx emissions, increasing output and maximizing availability. Discussion concerning the reduction of greenhouse gases is prevalent in the world. When taking a practical approach to addressing this problem, the best way and short-term solution to reduce greenhouse gases on coal-fired power plants is to improve efficiency. From this point of view the real time optimized combustion tuning approach is the most effective and implemented with minimal cost.

  • PDF

Performance Evaluation of Tertiary Post-denitrification Processes for the Reuse of Secondary Effluent from Wastewater Treatment Plant (하수2차처리수의 재이용을 위한 후탈질공정의 평가)

  • Lee, Chanho;Yun, Zuwhan;Yi, Yun Seok;Lee, Han Saem;Ahn, Dong Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.642-649
    • /
    • 2007
  • The effectiveness of add-on tertiary treatment processes for the polishing of the effluent of a biological nutrient removal (BNR) system from a modified $A^2/O$ process has been examined under the field condition with pilot-scale plants. The add-on treatment processes of 1) combined biofilm anoxic reactor and sand filtration, and 2) two-stage denitrification filter had been operated with various operating conditions. The experimental results indicated that two-stage denitrification filter could produced a better polished tertiary effluent. Filtration rate of $150m^3/m^2{\cdot}d$ for the 2-stage denitrifying filter could decrease the nitrate removal probably due to shorter detention time that caused insufficient reaction for denitrification. Two stage denitrification filter operated with M/N ratio of 3.0 and filtration rate of $100m^3/m^2{\cdot}d$ produced the tertiary effluent with nitrate and SS concentraitons of 2.8 mg/L and 2.3 mg/L, respectively. When the operating temperature reduced $30^{\circ}C$ to $18^{\circ}C$, $NO_3{^-}-N$ removal efficiency decreased from 73% to 68%.

Comparison of operational efficiency between sand-filtration process and membrane filtration process (모래여과 공정과 막여과 공정의 운영효율 비교)

  • Byeon, Kwangjin;Jang, Eunsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.529-537
    • /
    • 2017
  • Membrane filtration process is an advanced water treatment technology that has excellently removes turbidity and microorganisms. However, it is known that it has problems such as low economic efficiency and the operating stability. Therefore, this study was to evaluate on the economical feasibility and operational stability comparison of membrane and sand filtration process in Im-sil drinking water treatment plant. For the economic analysis of each process, the electricity cost and chemical consumption were compared. In the case of electric power consumption, electricity cost is $68.67KRW/m^3$ for sand filtration and $79.98KRW/m^3$ for membrane filtration, respectively. Therefore, membrane filtration process was about 16% higher than sand filtration process of electricity cost. While, the coagulant usage in the membrane filtration process was 43% lower than the sand filtration process. Thus, comparing the operation costs of the two processes, there is no significant difference in the operating cost of the membrane filtration process and the sand filtration process as $85.94KRW/m^3$ and $79.71KRW/m^3$ respectively (the sum of electricity and chemical cost). As a result of operating the membrane filtration process for 3 years including the winter season and the high turbidity period, the filtrated water turbidity was stable to less than 0.025 NTU irrespective of changes in the turbidity of raw water. And the CIP(Clean In Place) cycle turned out to be more than 1 year. Based on the results of this study, the membrane filtration process showed high performance of water quality, and it was also determined to have the economics and operation stability.

Energy Analysis in CO2 Membrane Separation Process via Heat Integration (열통합 기법을 통한 이산화탄소 막 분리공정 에너지 해석)

  • Kim, Seong Hun;Kim, Tae Yong;Kim, Beom Seok;Cho, Hyun-Jun;Yeo, Yeong Koo
    • Plant Journal
    • /
    • v.12 no.2
    • /
    • pp.24-30
    • /
    • 2016
  • The membrane separation processes have received attention due to advantages such as compactness, modularity, ease of installation, flexibility of operation, lower capital cost and lower energy consumption. In this study, we evaluated accuracy of cross-flow, co-current and counter-current models. With the most accurate model, we identified the operating conditions of the two-stage membrane separation and examined the effects of permeance and selectivity of the membrane by simulation. Futhermore, power requirements and operating cost savings due to the introduction of the heat exchanger were investigated by applying heat exchanger network synthesis technique in the two-stage membrane separation using vapor sweep.

  • PDF

Prevention of Insulation Damage Layer and Shell Corrosion in Thermal Storage Tanks for District Heating (지역난방용 축열조의 단열재 손상과 외각부식 개선방안)

  • Bang, Yong-Eoon;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.10 no.4
    • /
    • pp.35-41
    • /
    • 2014
  • The height and capacity of the thermal storage tank can be decided by the altitude and heat load of the heat supply area. Evaporation in heat pipe can be prevented by pressurizing it with the hydraulic head of the thermal storage tank. In addition, it absorbs the expanded volume from the temperature changes and supplies water to the pipelines in case of the shortage of water. One of the most important roles of the thermal storage tank is a stable heat supply facility. It can control the heat demand by accumulating the surplus heat and supplying in changing heat demand time. The purpose of this thesis is to be helpful for the operation and maintenance of the thermal storage tanks. The study has been carried out for 18 thermal storage tanks, which have been used polyurethane foam as insulation, among 27 tanks in district heating plants. The characteristics of the insulation materials, the reasons for the damages of the insulation and how impact the insulation damages to the corrosion of the thermal storage tank have been studied.

  • PDF

Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season (하절기 기화냉각장치 설치에 따른 가스터빈 성능변화)

  • Chung, Hyeon-Jo;Yoo, HoSeon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • This study analyzed the change of gas turbine performance with air temperature decrease by the evaporation cooling system in summer season. Gas turbine performance was tested on the condition that ambient temperature is $29{\pm}1^{\circ}C$. As a result, Air temperature at the compressor inlet was decreased by $4.12^{\circ}C$ after the installation of evaporation cooling system. Decreased air temperature followed by increased air density affected gas turbine performance, Which increased compressor pressure ratio by 0.27, improved compressor efficiency of 0.29 %p, improved gas turbine enthalpy drop efficiency of 0.31 %p, improved the gas turbine efficiency by 0.44 %p, improved electric power output by 4,489 kW. On the other side, the influence of the humidity increase and flow resistance increase was negligible.

  • PDF

Practical Use of Vegetated Porous Pavement for the Construction of Grass Parking Lot (잔디주차장 시공을 위한 잔디블록 활용방안)

  • Han, Seung-Ho;Kang, Jin-Hyoung;Choi, Joon-Soo;Yang, Geun-Mo;Yoon, Yong-Han;Ku, Tae-Ik;Kim, Won-Tae
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.1011-1015
    • /
    • 2009
  • The vegetated porous pavement can be installed as an alternative way to replace the traditional pavement, which contributes less to the water circulation system in the urban area. This study aims to an investigation based on the shadow and pressure of the vehicle system, where the turfgrass get grown and the green block get constructed on the grassy parking lot. This study might achieve these conclusions, in the case of use 'green block' makes grass parking lot, plant a kind of 'zenith' and takes sod thickness 40 mm are more efficient for turfgrass growth in the early times. In the case of parking over 8 hours in a day, after 5 weeks turfgrass growth would come into reduce. So over 4 hours parking and after 9 weeks, we need consider to setting up green block in grassy parking lot. The grassy ground would get pressured by the vehicles' load and it would bring into some damage due to the load after 3 weeks. So we should put the grass's growth root point under the designed a top of 'green block' level. When the vehicle amounts and parking density is in a low level, it could be an environmentally friendly product.

Study on the Properties of Light-weight Concrete containing Bottom Ash as a part of Fine Aggregate (바텀애시를 잔골재로 사용한 경량콘크리트의 특성에 관한 연구)

  • Lee, Jin-Woo;Kwon, Hae-Won;Park, Hee-Gon;Kim, Yoo-Jin;Bae, Yeoun-Ki;Lee, Jae-Sam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.701-704
    • /
    • 2008
  • Actuality, amount of electric power is rising together with business expansion. But the most power plant is consisted a thermal power. People have been burning fuel like a coal, and it bring the cinder concrete. Fly-ash is use to the high-degree in construction material, but in case of bottom-ash had been disused the whole quantity. Intermittently, the academic world laid his studies for bottom-ash. Thus, this study contents are a characteristic of be not harden concrete incorporating fine aggregate, a strength of harden concrete, elastic modulus and a unit mass. And there do for the sake to examine utility value of bottom-ash and improve of light weight concrete.

  • PDF

Experimental Study of Flow Fields around a Perforated Breakwater

  • Ariyarathne, H.A. Kusalika S.;Chang, Kuang-An;Lee, Jong-In;Ryu, Yong-Uk
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • This study investigates flow fields and energy dissipation due to regular wave interaction with a perforated vertical breakwater, through velocity data measurement in a two-dimensional wave tank. As the waves propagate through the perforated breakwater, the incoming wave energy is reflected back to the ocean, dissipated due to very turbulent flows near the perforations and inside the chamber, and transmitted through the perforations of the breakwater. This transmitted energy is further reduced due to the presence of the perforated back wall. Hence most of the energy is either reflected or dissipated in the vicinity of the structure, and only a small amount of the incoming wave energy is transmitted through the structure. In this study, particle image velocimetry (PIV) technique was employed to measure two-dimensional instantaneous velocity fields in the vicinity of the structure. Measured velocity data was treated statistically, and used to calculate mean flow fields, turbulence intensity and turbulent kinetic energy. For investigation of the flow pattern, time-averaged mean velocity fields were examined, and discussed using the cross-sections through slot and wall for comparison. Flow fields were obtained and compared for various cases with different regular wave conditions. In addition, turbulent kinetic energy was estimated as an approach to understand energy dissipation near the perforated breakwater. The turbulent kinetic energy was distributed against wave height and wave period to see the dependence on wave conditions.

An Ecological Corridor Plan in an Urban Neighborhood Park - A Case Study of Noryangjin Neighborhood Park in Dongjak-gu, Seoul - (도심지역 산지형 근린공원내 도로에 의한 단절지역 생물이동통로 조성계획 연구 - 동작구 노량진근린공원을 대상으로 -)

  • Han Bong-Ho;Kim Jeong-Ho;Kim Jong-Sik
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.16-31
    • /
    • 2005
  • This study was carried out to design a bridge-type ecological corridor plan in a forested neighborhood park affected by road construction in Dongjak-gu, Seoul. In order to study the site conditions, we analyzed topography, ecosystem structure, and user behavior and trail use. Existing vegetation was classified into 12 types. Based on a vegetation analysis, the Populus albaglandulosa and Robinia pseudoacacia communities, where planted species are dominant, were distributed extensively in the southern forest area. Planted areas with a single-layer structure of Korean landscape woody plants and Robinia pseudoacacia communities with a single-layer structure were distributed extensively in the northern forest and water-supply area. Based on a study of 28 quadrats, the similarity index between the multi-layer plant communities distributed in the southern forest and the single-layer planted areas was low. Twenty-four species of wild birds(355 individuals) were found in the survey area, including nine interior species and three urban species. The study of user behavior and numbers showed most users were walkers and few users were observed in the southern forest while most users were observed in the northern forest and water supply area. We selected some wild birds as model species to represent migrating species believed to use this park as an ecological corridor during migration. We suggested the new park plan include the following: improvement of vegetation structure for wildbird migration and habitat, connection of park trails for users and presentation of a landscape linked to nature.