• 제목/요약/키워드: plant's noise

검색결과 116건 처리시간 0.024초

발전소 주증기 배관 소음 발생 원인 규명 (Identification of Noise Source from Main Steam Line in Power Plant)

  • 손석만;이준신;이선기;이욱륜;이상국
    • 동력기계공학회지
    • /
    • 제7권3호
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

산업현장의 소음.진동 원인분석 및 저감방안 연구 (Assessment of Can Factory working noise and its reduction)

  • 전형준;고준희;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.212-216
    • /
    • 2006
  • The purpose of this study is to obtain an effective enclosing method for noise reduction of press machine operating in a manufacturing company located in Korea. Noise level of the machine is about $90{\sim}105dB$ which is higher than legal standards by industrial safety and health law. This study has predicted the level of noise reduction according to a step by step prevention plan by considering the characteristics of the cause of noise, the permitted limit of noise levels, problems and economical efficiency attendant upon the noise prevention measures. The predicted level of noise at the plant in accordance with the first step is $71.5{\sim}89.5dB(A)$, and can satisfy the permitted limit of noise in a time period of the day. Based on these results, enclosing method adequate for the selected plant's noise characteristics were suggested.

  • PDF

도심지 복합화력 배가스 통로에서의 이상 소음 현상과 영향 (Abnormal Resonance Noise Phenomenon and Effect through Exhaust Gas Passageway in Urban Combined Power Plant)

  • 김연환;이영신;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.866-869
    • /
    • 2004
  • Power transformers, air-intakes and stacks in the urban combined power plant are main noisy sources. Because of Inhabitant complaint by abnormal noise transferred from the power plant. the noise was investigated at power plant and uptown area. The result of diagnosis made the acoustic resonance phenomenon by 580Hz's combustion dynamic pressure with the standing wave mode of sound fields in exhaust passageway of gas turbine into main noise source of public complain. The abnormal noise is caused by the resonance exhaust noise transferred through stacks of power plant.

  • PDF

발전소 관리실의 작업환경 소음에 관한 연구 (A Study on the Workplace Noise Environment of Office Areas in Power Plant)

  • 김병삼
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

발전소 플랜트 소음영향평가 현황 및 민원사례를 통한 개선방향 연구 (A Study on Review of the Current Noise Impact Assessment for the Power Plant)

  • 정태량;박영민;손진희;조만희;홍웅기;송정언
    • 환경영향평가
    • /
    • 제21권6호
    • /
    • pp.941-949
    • /
    • 2012
  • The various plants including power plants have been increased near downtown in accordance with the policy objective of rising the power feed rate and development projects. As a result of these various plants near residential area, noise damage complaints has been raised very often. The power plant is included with the range of environmental impact assessment project. Nevertheless, environmental noise issues regarding construction of these power plants have arisen. Accordingly it is time to consider the environmental and social issues of plants noise in accordance with the government's policy objectives of increased power production. In this study, we reviewed the current noise impact assessment and we also sought solutions to these issues. In order to minimize the problem of noise impact on neighborhood and residents, we intended to propose alternative method of 3D simulation in dealing with these issues.

LCD공장 내부의 온도센서 노이즈진단 및 억제에 관한 연구 (A Study on the Noise Diagnosis and Suppression of the Temperature Sensor in the LCD Plant)

  • 김경철;최형범;황영록;김용관;유창훈
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.35-41
    • /
    • 2012
  • As automation equipment and electronic device progresses, the importance of power quality is more increasing. This paper represents the analysis and suppression about the causes of trouble by the inverter's ON/OFF noise in plant in order to prevent damage resulting in a secondary damage to conduct precise diagnosis and effective noise reduction. The countermeasure as a reduced carrier frequency and the LC resonant filter had been applied and confirmed the effective results to solve the trouble of noise.

DSP를 이용한 고장허용을 갖는 신뢰 적응 필터 설계 (Design of Reliable Adaptive Fitter with Fault Tolerance Using DSP)

  • 유동완;이전우;서보혁
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권1호
    • /
    • pp.8-13
    • /
    • 2001
  • LMS algorithm has been used for plant identifier and noise cancellation. This algorithm has been researched for performance enhancement of filtering. The design and development of a reliable system has been becoming a key issue in industry field because the reliability of a system is considered as an important factor to perform the system's function successfully. And the computing with reliability and fault tolerance is a important factor in the case of aviation, system communication, and nuclear plant. This paper presents design of reliable adaptive filter with fault tolerance. Generally, redundancy is used for reliability. In this case it needs computing or circuit for voting mechanism, or fault detection. Therefore it has simple computing, and practicality for application. And in this paper, reliability of adaptive filter is analyzed. The effectiveness of the proposed adaptive filter is demonstrated to the case studies of plant identifier and noise cancellation by using DSP.

  • PDF

Analysis of Living Noise in a Multi-unit Dwelling using Acoustic Simulation

  • Yang, Ginam;Ann, Joon-suk;Kim, Daewon;Kim, Gwang-Hee;Shin, Yoonseok
    • 한국건축시공학회지
    • /
    • 제16권1호
    • /
    • pp.87-96
    • /
    • 2016
  • More than half of Korea's urban population currently lives in multi-unit dwellings. This particular residence structure inevitably positions the living spaces of residents in close proximity to one another. Because of this proximity, the sounds of a particular household will transfer to other residents' units creating conflict between tenants. Efforts to alleviate this problem have been made in both the public and private sector. A prominent method of noise analysis between living units has been to make an actual sound measurement and obtain qualitative measurements from questionnaires. Although this method has been most widely used, such analysis requires a large amount of human effort and time. In addition, the questionnaire method fails to provide the objective information needed to accurately assess the noise situation. To overcome the inadequacies of this previous method, this study seeks to evaluate the applicability of an acoustic simulation method. Three types of living noises were analyzed to assess the noise levels passed between multi-unit dwellings. The acoustic simulation method was found to be more economical, efficient, and adaptable in information processing. The results of this study can be further applied to design and control living-noise through procedures such as acoustic absorption or space redesign.

노이즈 환경 하에서 태스크와 메시지 스케줄링 (Scheduling of Tasks and Messages under Noise Environment)

  • 김형육;윤건;박홍성
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.377-384
    • /
    • 2004
  • Nowadays, control systems consist of smart sensors, smart actuators, and controllers connected via fieldbus. Some devices such as motors in plant environments generate high degrees of EMI or noise. This noise may cause communication errors and make the successful transmission of data longer. Therefore, the noise condition has to be considered at the design of a reliable control system based on a network. This paper presents a scheduling method of task and message to guarantee the given end-to-end constraints under noise environments. A noise model with multi-sources of noise is used, and the analysis method of message's response time is presented when the noise model is applied to CAN (Controller Area Network). Two kinds of noise models are applied to an example system, and the effect to each control loop s end-to-end response time is analyzed. We believe that the proposed method help system designers design the control system guaranteeing its requirements under noise environment.