• 제목/요약/키워드: pinch-of

검색결과 310건 처리시간 0.03초

5-MeV Proton-irradiation characteristics of AlGaN/GaN - on-Si HEMTs with various Schottky metal gates

  • Cho, Heehyeong;Kim, Hyungtak
    • 전기전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.484-487
    • /
    • 2018
  • 5 MeV proton-irradiation with total dose of $10^{15}/cm^2$ was performed on AlGaN/GaN-on-Si high electron mobility transistors (HEMTs) with various gate metals including Ni, TaN, W, and TiN to investigate the degradation characteristics. The positive shift of pinch-off voltage and the reduction of on-current were observed from irradiated HEMTs regardless of a type of gate materials. Hall and transmission line measurements revealed the reduction of carrier mobility and sheet charge concentration due to displacement damage by proton irradiation. The shift of pinch-off voltage was dependent on Schottky barrier heights of gate metals. Gate leakage and capacitance-voltage characteristics did not show any significant degradation demonstrating the superior radiation hardness of Schottky gate contacts on GaN.

외상성 수지 절단에서 인지 재건을 위한 제 2 족지이식 (Second Toe to Finger Transfer in Traumatic Amputated Index)

  • 이광석;한승범;이승준;박성준
    • Archives of Reconstructive Microsurgery
    • /
    • 제11권1호
    • /
    • pp.41-46
    • /
    • 2002
  • Purpose : To assess the clinical results of second toe-to-finger transfer in traumatic amputated index finger. Materials and Methods : For the clinical evaluation, we have analyzed 12 patients with ROM of finger joints, pinch power, static two point discrimination, life functional assessment, and patient's satisfaction. Results : In genral ROM was $54.4^{\circ}$ at MP joint, $17^{\circ}$ at PIP joint and $6.7^{\circ}$ at DIP joint. Pinch power was good in 3 cases, fair in 7 cases, and poor in 2 cases. Daily life activity and patient's acceptance were satisfactory. Conclusion : Although transfered toe function may be poorer than normal finger, the hand was restored to a useful, sensate and versatile functional unit.

  • PDF

신경역동적 기법과 자가 신경 운동법이 수근관증후군 환자에게 미치는 영향 (The Effect of Neurodynamic Technique and Self Management Exercise for Carpal Tunnel Syndrome Patients)

  • 박현식
    • 대한정형도수물리치료학회지
    • /
    • 제16권2호
    • /
    • pp.48-52
    • /
    • 2010
  • Object: The aim of this study is to descrive the effect of neurodynamic technique and self management exercise for carpal tunnel syndrome patients(CTS) Method: 13 patients with CTS participated in this study. They were from 18 to 70 years old and mean age was 25.3. In the evalutaion, gripping with grip dynamometer, strength of gripping with precision pinchmeter, pain level with visual analogue scale. All measurement of each subject were measure at pre- treatment and post treatment(after 1week) and post treattment(after 2 weeks) stage. The physical therapy program consisted of neurodynamic technique and self management exercise. SPSS 12.0 program was used to compile result. Result: The grip, pinch, VAS-P were significantly difference between pre-treatment and post treatment(after 2weeks)(p<.05) Conclusion: This study suggest that 3weeks neurodynamic technique and self management exercise improved grip and pinch strength and decrease pain score.

  • PDF

노동현장 기준데이터 제시를 위한 손근육의 근활성도 및 근피로도에 관한 연구 (A Study on the Muscle Activity and Fatigue of Hand Muscle for the Presentation of Normative Data in Labor Environment)

  • 김경현;이호용;신화영;정성훈;김성환
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2336-2344
    • /
    • 2008
  • In this paper, muscular activity and muscle fatigue of FDI(first dorsal interosseous muscle) and thenar muscle of hand was analyzed with surface EMG signal based on four kinds of attitudes(grip, tip, key and palmar) to measure grip strength and pinch strength after hand operation and rehabilitation treatment. The normative data are needed to interpret evaluation data to assess a patient's ability to return to labor environment. The preceding researchers proposed the standard data only by studying on maximum grip strength and the maximum pinch strength followed by each attitude of subjects' hands. But in this study, the muscle activity and muscle fatigue were considered under the various attitude to propose normative data. As a results, the muscle fatigue may be used only for presentation of normative data in labor environment.

티타니아 세라믹 熔射皮膜의 機械的 特性에 미치는 熔射條件의 影響에 관한 硏究 (Effects of Spraying Conditions on the Mechanical Properties of Titania Ceramic Coating Layer)

  • 김영식;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권3호
    • /
    • pp.39-44
    • /
    • 1991
  • The purpose of this investigation is to examine the effects of spraying conditions on the mechanical properties of flame-sprayed titania ceramic coating layer. Titania ceramic was sprayed onto the mild steel substrate under the various spraying conditions. Spraying distances were 100, 150, 200, 250mm respectively and pinch air pressures were 0.2 0.3, 0.4 MPa at each spraying distance. The mechanical properties such as microhardness, adhesive strength and erosion wear resistance were tested for the specimens sprayed under the various spraying conditions above mentioned. The optimum operational conditions obtained through the experimental results were 150mm of spraying distance and 0.3 MPa of pinch air pressure.

  • PDF

바이어스 자계와 고주파 회전자계에 의한 역전자계 배위 형성 (The Formation of Reserved Field Configuration with Bias Field and Radio-Frequency Rotating Field)

  • 채규훈;김동필
    • 대한전기학회논문지
    • /
    • 제38권10호
    • /
    • pp.840-847
    • /
    • 1989
  • It is an important problem that the plasma of high B value is to be confined safely in the research of plasma fusion. So, the Reversed Field Pinch (RFP) plasma has been studied. RFP is stable pinch having self-reversal phenomenon that forms reversed field of itself, but its process of formation is unstable. Therefore, in this paper, we configured the stable RFP by supplying the radio-frequency rotating field just before the RFP is configured by self-reversal phenomenon. Moreover, when conductivity wall is used, toroidal configured by self-reversal phenomenon. Moreover, when conductivity wall is used, toroidal flux is subject to heavy fluctuation in case of high bias field compared with low bias field.

이행형 토치에서의 아크 플라즈마의 물리적 거동에 관한 연구 (A study on the physical behavior of arc plasmas in transferred-type Torch)

  • 김외동;고광철;강형부
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.415-425
    • /
    • 1996
  • This study presents an analytical method of solving the behaviors of arc plasma in a nozzle constricting transferred-type torch and purposes to obtain the basic data for the design of a plasma torch, which can be obtained from the temperature, pressure, velocities and voltage distributions. We have to solve some conservation equations simultaneously and need to know the exact thermal gas properties in order to obtain the correct behaviors of arc plasma. It is also necessary to give the relevant physical or geometric boundary conditions. For the simplicity of analysis, we assumed that (a) the plasma flow is laminar, (b)the local thermodynamic equilibrium, i.e. LTE, prevails over the entire arc column region. The electrode sheath effects were neglected and the nozzle area was excluded from the analysis by assuming that the current flow into the nozzle is zero. We solved the momentum transfer equation including the self-magnetic pinch effect, and obtained the temperature distribution from the energy conservation equation. From this temperature, we could get arc voltage distribution. (author). refs., figs., tabs.

  • PDF

Extreme Ultraviolet Plasma and its Emission Characteristics Generated from the Plasma Focus in Accordance with Gas Pressure for Biological Applications

  • Kim, Jin Han;Lee, Jin Young;Kim, Sung Hee;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.178.2-178.2
    • /
    • 2013
  • Conventional ultraviolets A,B,C are known to be very important factor of killing, changing surface properties of biological cells and materials. It is of great importance to investigate the influence of extreme ultraviolet (EUV) exposure on the biological cell. Here we have studied high density EUV plasma and its emission characteristics, which have been generated by plasma focus device with hypercycloidal pinch (HCP) electrode under various Ar gas pressures ranged from 30~500 mTorr in this experiment. We have also measured the plasma characteristics generated from the HCP plasma focus device such as electron temperature by the Boltzman plot, plasma density by the Stark broading method, discharge images by open-shuttered pin hole camera, and EUV emission signals by using the photodiode AXUV-100 Zr/C.

  • PDF

GaAs SBGFET의 잡음동작에 관한 연구 (Study on Noise Behavior of GaAs SBGFET)

  • 박한규
    • 대한전자공학회논문지
    • /
    • 제14권3호
    • /
    • pp.6-11
    • /
    • 1977
  • GaAs Schottky Barrier Gate 전계효과트랜지스터의 잡음동작을 잡음등가회로를 사용하여 연구하였으며, 부가구인 잡음근원은 pinch-off영역에서 GaAs FET bias에 의하여 구현되었다. 이것이 바로 intervalley 산란잡음과 hot electron에 의한 잡음이었다. 본 논문의 잡음등가회로에서는 carrier의 포화속도와 기생저항의 영향을 고려한 parameter를 정하였다.

  • PDF

우세측에 따른 상지와 하지의 기능 비교 (Comparison of Upper and Lower Limb Functional Ability Depends on Dominants)

  • 이선명
    • 한국임상보건과학회지
    • /
    • 제4권3호
    • /
    • pp.622-633
    • /
    • 2016
  • Purpose. The purpose of this study was compared of left dominant and the right dominant hands about coordination. Methods. The participants were 30 occupational therapy students in M university in Changwon, from April 28th 2015 to May 1. The test tools were Jebson-Taylor Hand Function Test, Hand Strength & Pinch, Grooved Pegboard Test, Box & Block and Balance Test. Results. Right dominant hand was higher than left dominant in hand grip and dexterity, hand manipulation skills. And one leg standing and toe standing were higher left foot than right foot dominant. Conclusion. Most of all evaluation items showed a better result right dominant hand than left dominant. But shows that there is no functional difference between left-hand dominant than right-hand. So left-hand dominant coordination was evaluated by a better than right-handed.