• 제목/요약/키워드: photo sensor

검색결과 344건 처리시간 0.03초

에어셀을 이용한 손목 재활훈련 장치 (Wrist Rehabilitation Training Device Using Pneumatic Inflation and Deflation of Air Cells)

  • 이영진;정유진;구교인;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권2호
    • /
    • pp.37-42
    • /
    • 2015
  • In this paper, we propose a wrist rehabilitation training device using pneumatic inflation and deflation of air cells. By alternating inflation and deflation of upper and lower air cells, the device makes the flexional and extensional movement for wrist rehabilitation. With the angular displacement sensor, it measures the flexion-extension angle of the wrist during the training and the bending angle is used for the automatic control of the device. Using the sensor output, the regression equation was obtained to measure the bending angle of the wrist from a wrist rehabilitation training device. The measurement error of the device was evaluated by comparing the measurement output with the angle from the photograph. The measurement error of wrist bending angle between the sensor and photo was $3.2^{\circ}$ in average. With additional test and improvement, the pneumatic wrist rehabilitation training device might be used for rehabilitation training.

롤링셔터 효과를 이용한 광학 카메라통신 알고리즘 (Algorithm of Optical Camera Communications Using Rolling-Shutter Effect)

  • 이정호;김나영;주민철;박영일
    • 한국통신학회논문지
    • /
    • 제41권4호
    • /
    • pp.454-460
    • /
    • 2016
  • 광학 카메라 통신(OCC, Optical Camera Communication)은 기존의 광다이오드 기반 가시광통신(VLC)과는 다르게 카메라를 수신부로 사용하여 데이터를 수신한다. 특히, 카메라의 CMOS 이미지 센서의 셔터 동작방식인 롤링셔터의 원리를 이용하면 픽셀별로 다른 신호를 수신할 수 있으므로 데이터 속도를 개선할 수 있다. 본 연구에서는 카메라의 CMOS 이미지 센서를 사용하여 LED로부터 송신되는 고속 데이터의 이미지를 실시간으로 획득하고 이를 처리할 수 있는 알고리즘을 제안하였으며, 실험을 통해 성능을 검증하였다.

센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구 (Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs)

  • 김명수;김형택;강동욱;유현준;조민식;이대희;배준형;김종열;김현덕;조규성
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

유연성 광전도 CdS 박막의 증착조건에 따른 전기적 특성 및 신뢰성 평가 연구 (Electrical Properties and Reliability of the Photo-conductive CdS Thin Films for Flexible Opto-electronic Device Applications)

  • 허성기;조현진;박경우;안준구;윤순길
    • 한국전기전자재료학회논문지
    • /
    • 제22권12호
    • /
    • pp.1023-1027
    • /
    • 2009
  • Cadmium sulfide (CdS) thin film for flexible optical device applications were prepared at $H_2/(Ar+H_2)$ flow ratios on polyethersulfon (PES) flexible polymer substrates at room temperature by radio frequency magnetron sputtering technique. The CdS thin films deposited at room temperature showed a (002) preferred orientation and the smooth surface morphologies. Films deposited at a hydrogen flow ratio of 25% exhibited a photo- and dark-sheet resistance of about 50 and $2.7\;{\times}\;10^5\;{\Omega}/square$, respectively. From the result of the bending test, CdS films exhibit a strong adhesion with the PES polymer substrates and the $Al_2O_3$ passivation layer deposited on the CdS films only shows an increase of the resistance of 8.4% after exposure for 120 h in air atmosphere.

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

직분식 디젤기관 전자분사계의 광검출기 적용에 관한 연구 (A Study on Application of the Photo Detector for Electromagnetic Fuel Injection System of DI Diesel Engine)

  • 라진홍;안수길
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.38-46
    • /
    • 1999
  • Increasing stringent emissions legislation and requirement of more effective energy used for diesel engine demand the fine control of the fuel injection system. Recently, the electromagnetic fuel injection control system for diesel engine is tried to realize the optimum diesel combustion by the feel back sensing as optical signal of combustion flame. The photo detectors were made for the feed back signal of electromagnetic fuel injection control for small DI diesel engine. Their abilities to detect defining combustion events were examined. By evaluating test results, it was shown that the wider acceptable optical range design of optical probe window face, and selection of installation position and installation method of detector were important point for improving sensing ability. The detector was shown to detect start and end of diffused combustion and maximum point of flame intensity impossible for pressure sensor, and also shown that the maximum point of flame intensity was 75% of accumulated heat release point within the experimental conditions.

  • PDF

SOI NMOSFET을 이용한 Photo Detector의 특성 (Properties of Photo Detector using SOI NMOSFET)

  • 김종준;정두연;이종호;오환술
    • 한국전기전자재료학회논문지
    • /
    • 제15권7호
    • /
    • pp.583-590
    • /
    • 2002
  • In this paper, a new Silicon on Insulator (SOI)-based photodetector was proposed, and its basic operation principle was explained. Fabrication steps of the detector are compatible with those of conventional SOI CMOS technology. With the proposed structure, RGB (Read, Green, Blue) which are three primary colors of light can be realized without using any organic color filters. It was shown that the characteristics of the SOI-based detector are better than those of bulk-based detector. To see the response characteristics to the green (G) among RGB, SOI and bulk NMOSFETS were fabricated using $1.5\mu m$ CMOS technology and characterized. We obtained optimum optical response characteristics at $V_{GS}=0.35 V$ in NMOSFET with threshold voltage of 0.72 V. Drain bias should be less than about 1.5 V to avoid any problem from floating body effect, since the body of the SOI NMOSFET was floated. The SOI and the bulk NMOSFETS shown maximum drain currents at the wavelengths of incident light around 550 nm and 750 nm, respectively. Therefore the SOI detector is more suitable for the G color detector.

A comparison of photosynthesis measurements by O2 evolution, 14C assimilation, and variable chlorophyll fluorescence during light acclimatization of the diatom Coscinodiscus granii

  • Trampe, Erik;Hansen, Per Juel;Kuhl, Michael
    • ALGAE
    • /
    • 제30권2호
    • /
    • pp.103-119
    • /
    • 2015
  • Photosynthetic rates of the large centric diatom Coscinodiscus granii were measured by means of multicolor variable chlorophyll fluorescence imaging, single cell $^{14}C$ assimilation, and optical $O_2$ sensor measurements during light acclimatization of cultures grown at five different irradiances: 50, 150, 235, 332, and $450{\mu}mol$ photons $m^{-2}\;s^{-1}$. Photo-acclimatization was evident from changes of cellular chlorophyll a content, growth rates, and light response curves. Each of the applied methods evaluates different parts and reactions in the photosynthetic apparatus, which makes a direct quantitative comparison of rates difficult, although a different degree of correlation were found between all three methods. However, when used in combination, they provide information about the internal relationship of photosynthetic pathways as well as the variation in photosynthetic capacity between individual cells within a single algal culture.

자동제어식 파종조절장치 개발 (Development of Automatic Seed Metering Device)

  • 이용국;이대원;오영진
    • Journal of Biosystems Engineering
    • /
    • 제19권2호
    • /
    • pp.91-98
    • /
    • 1994
  • Planting, transplanting, and harvesting are important processes for the successful production of farm products in Korea because those require the high labor intensity during limitted period. Recently, many researches of using automatic control with a microcomputer are carried in the agricultural field, but are not much spread to the seeder development. Automatic sowing technology would be much attractive if there was a way to assure that each seed was count accurately in the seed metering device. Thus, an automatic seed metering device was designed and constructed to be controlled by microcomputer. This device could be improved in not only counting the number of seeds in but also sowing seeds between row spacings. Automatic seed metering device consisted of conveyor belt and temporary storage device. Performance of seed metering device depends on the apparatus including sensor, stepping motor and DC-solenoid. Research contents and results are summarized as follows. 1. The seed metering device involving seed hopper, sorter and temporary storage device was designed and constructed. 2. A seed counting system with six photo electric sensors, designed and built for this project, was adequate for tranferring and counting seeds accurately. 3. Operating algorithm for stepping motor and photo electric DC-solenoid was developed. The Seed metering device proved to be a smooth and accurate operating device using the algorithm. 4. The performance of second prototype metering device was examined with five kinds of seeds ; mung beans, red beans, white beans, black beans and corn to transfer and count the seeds. The error ratio of seed metering was less than 3.5%.

  • PDF

저가형 요분석 시스템의 다중 광 검출 모듈개발 (Development of multi-colorimeter module for low-cost urinalysis strip readers)

  • 예수영;전용욱;정도운;전계록;노정훈
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.