• Title/Summary/Keyword: photo sensitivity

Search Result 124, Processing Time 0.024 seconds

A Fluorescent Sensor Film for Detecting pH of Acidic Solutions (산성 용액의 pH를 감지할 수 있는 형광 센서막)

  • Min, Jae Young;Kim, Hyung Jin
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.74-78
    • /
    • 2020
  • A push-pull conjugated dye (DCMP) was covalently immobilized on a silanized glass surface to produce a high sensitivity pH sensor film for operating in the acidic region. A pH-sensitive sensor film was prepared by photo-initiating copolymerization of a modified DCMP (DCMA), 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate on the silanized glass surface. The absorbance of the sensor film increased with increasing pH between pH 2.0 and 5.0, and the fluorescence intensity of the film also increased about 50 times with increasing pH in the same pH range. The sensor film was reversible and reproducible under acidic conditions. The sensor film showed a relatively short response time between 20-50 seconds and high selectivity for proton in the presence of various metal ions.

Broad Beam Gamma-Ray Spectrometric Studies with Environmental Materials

  • El-Kateb, Abdul-Hamid Hussein
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Background: Gamma-ray spectrometry helps in radiation shielding problems and different applications of radioisotopes. Experimental arrangements including broad beam geometries are widely used. The aim is to investigate and evaluate the ${\gamma}-ray$ spectra via attenuation by environmental materials. Materials and Methods: The photo peak to nominated parts in the ${\gamma}-ray$ spectra and the attenuation coefficients ${\mu}_b/{\rho}$ from broad beam geometries are measured for the materials water, soil, sand and cement at the energies 0.662, 1.25, and 1.332 MeV with a $3{^{\prime}^{\prime}}{\times}3{^{\prime}^{\prime}}$ NaI(Tl) detector. Results and Discussion: The ${\gamma}-ray$ spectra vary according to changes in the effective atomic number $Z_{eff}$ of the attenuator, the photon energy and the solid angle. The peak to total ratios are the most sensitive parts to variations in the experimental conditions and overturn in the region 0.663 MeV to 1.332 MeV. This is indicated as inversion trend. The results are discussed in view of $Z_{eff}$ and the experimental conditions. The intensity build-up is larger at the lower energy and larger scattering angles in agreement with Klein-Nishina formula and other results. The build-up factor B is$${\sim_=}$$1 at high ${\gamma}-energies$ and small scattering angles. Conclusion: The sensitivity to material characteristics decrease gradually from peak: to total, to Compton valley, to Compton plateau ratios. Rigorous collimation is necessary at small energies. Cement, of the largest $Z_{eff}$, is characterized by the maximum broad beam mass attenuation coefficients ${\mu}_b/{\rho}$. The obtained results provide information to decide for the suitable experimental set-up based on aim of the work.

The Study of Radiation Sensitivity on Fiber Bragg Grating Written in Photo-sensitive Optical Fibers (광민감 광섬유로 제작한 광섬유 브래그 격자 센서의 방사선 민감도에 대한 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2023-2028
    • /
    • 2014
  • In this study, we studied the effect of $Co^{60}$ gamma-radiation on the FBGs written in photo-sensitive and commercial Ge-doped single-mode optical fibers. The FBGs were exposed to gamma-radiation up to a dose of 17.8 kGy at the dose rate of 300 Gy/min. According to the experimental data and analysis results, the lowest Bragg wavelength shift (18 pm) was obtained by a grating written in photosensitive fiber without $H_2$-loading. Also, we confirmed that the H2 loading process has considerably more influence on the Bragg wavelength shift change under gamma radiation than $GeO_2$ contents in the fiber core.

The Preparation and Release Property of Alginate Microspheres Coated Gelatin-cinnamic Acid (젤라틴-신남산 접합체가 코팅된 알긴산나트륨 마이크로스피어의 제조 및 방출 특성)

  • Lee, Ju Hyup;Ma, Jin Yeul;Kim, Jin-Chul
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.471-475
    • /
    • 2013
  • This study is about photosensitive microspheres prepared by coating alginate microspheres with gelatin-cinnamic acid conjugate. Firstly, alginate microspheres was prepared in water-in-oil (W/O) emulsion and then they were coated with gelatin- cinnamic acid conjugate. Herein, gelatin-cinnamic acid conjugate is obtained by the amidation between an amine group of gelatin and a carboxy group of cinnamic acid. Cinnamic acid is widely used as a photo-responsive material easy to dimerize and dedimeriz under UV irradiation at ${\lambda}$ = 254 nm and ${\lambda}$ = 365 nm, respectively. As shown in SEM-EDS, alginate was successfully coated with gelatin-ciannmic acid. By determining the absorbance of coated microspheres at 270nm, the amount of cinnamic acid per microspheres was 0.13/1. The SEM photos showed the size of coated microspheres is around $10{\mu}m$. And the degrees of dimerization and dedimerization were calculated to be 49% and 23% respectively. Then the release of FITC-dextran from the coated micrspheres was studied and release the degree was 42%. As a result, the coated microspheres have potential to be used as a photo-responsive drug carrier to delivery drugs.

Fabrication and characterization of CdS photoconductive cell by the print/sintering method (인쇄/소결 방법에 의한 CdS 광전도 셀 제작과 특성)

  • Jeong, Tae-Soo;Kim, Taek-Sung;Jeong, Cheol-Hoon;Lee, Hoon;Shin, Yeong-Jin;Hong, Kwang-Joon;Yu, Pyeong-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.350-355
    • /
    • 1998
  • We fabricated a photoconductive cell made of polycrystalline CdS thick film which has high photo-sensitivity using a print/sintering method. The resultant grain size is about $4\;{\mu}m$. When $CuCl_2$ of 0.06 to 0.12 mg is added, the sensitivity and the ratio of photocurrent to dark current are 0.8 and $10^5$, respectively. The response wavelength is 511 nm. The rise and decay response times are 50 and 20 ms, respectively. In addition, the maximum power dissipation is beyond 80mW. We noticed that the addition of $CuCl_2$ between 0.06 and 0.12 mg to 1g of CdS results in a reliable formation of photoconductive sensor.

  • PDF

Changes in Cytosolic $Ca^{2+}$ but not in cGMP Contents May be more Important to Nitric Oxide-Mediated Relaxation in Depolarized Vascular Smooth Muscle

  • Lee, Hyun-Seok;Chang, Ki-Churl
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.1
    • /
    • pp.63-68
    • /
    • 1998
  • Nitric oxide (NO)-mediated relaxation in vascular smooth muscle involves not only activation of guanylate cyclase but also hyperpolarization of the membrane. It has been shown that depolarization decreases the [$Ca^{2+}$] sensitivity of myosin light chain kinase in arterial smooth muscle, and nitric oxide (NO)-mediated relaxation was attenuated in this situation. However, why potassium inhibits or attenuates the action of EDRF/NO is not clear. Therefore, we investigated the magnitude of relaxation and cGMP contents using measures known to release NO, such as photorelaxation, photo activated NO-mediated relaxation, and NO-donor (SNP)-mediated relaxation in porcine coronary arterial rings in which contractile conditions were made by different degree of depolarization, i.e., contraction in response to U46619 or U46619 plus KCl. In all cases, the magnitude of relaxation was significantly greater (P<0.05) in U46619-contracted rings than in U46619+KCl-contracted ones. Although accumulation of cGMP was evident with three measures employed in the present study, no difference was found in cGMP contents between U46619 and U46619+KCl conditions, indicating that the diminished relaxation in KCl containing solution is cGMP-independent mechanism(s). To understand this further, cytosolic $Ca^{2+}$ changes due to NO were compared in rat thoracic aorta by exploiting photoactivated NO using streptozotocin (STZ) that was contracted with either NE or KCl. Fura-3 $[Ca]_{cyt}$ signal caused by NO was small and transient in high $K^+$-, but large and sustained in NE-contracted aorta. The inhibitory potency of STZ expressed in terms of $IC_{50}$ was 5.14 and 3.88 ${\mu}M$ in NE and in high $K^+$, respectively. These results suggest that modification of the cellular mobilization of $Ca^{2+}$ rather than cGMP levels may be an important mechanism for the NO-mediated relaxation when vascular membrane is depolarized, such as atherosclerosis and hypertension.

  • PDF

Effects of Temperature and Day-Length on Heading Habit of Recently Developed Korean Rice Cultivars

  • Choi, Kyung-Jin;Lee, Jung-Il;Chung, Nam-Jin;Yang, Won-Ha;Shin, Jin-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • To understand the heading habit of recently developed 20 Korean rice cultivars, rice plants in a phytotron were exposed to different temperature: $22.5^{\circ}C(day\;27^{\circ}C/night\;18^{\circ}C),\;27.5^{\circ}C(day\;32^{\circ}C/night\;23^{\circ}C)$, and day-length conditions: 10, 12, 13, 14, 15 hours. Four rice cultivars (Sobibyeo, Juanbyeo, Ilpumbyeo and Shindongjinbyeo) showed relatively short Basic Vegetative Phase (BVP) of 17 to 18 days, while Dasanbyeo showed the longest (35 days) BVP, compared to other remaining 15 tested cultivars which exhibited 24 to 31 days of BVP. In this experiment, it was tried out to separate the eliminable vegetative phase into photosensitivity and thermo-sensitivity with two different pathways. Many tested cultivars, however, exhibited quite different responses under low temperature and / or long day-length conditions. Especially, Surabyeo and Juanbyeo were the most difficult cultivars to separate into photo- or thermo-sensitivity in that the eliminable vegetative phase of these two cultivars increased greatly only under low temperature $(22.5^{\circ}C)$ and long day-length (15 hr.) conditions. Regarding the heading response to temperatures, tested cultivars could be categorized into 2 groups. In 1st group of rice cultivars, the eliminable vegetative phase decreased almost equally as the temperature changed from $20.0^{\circ}C\rightarrow22.5^{\circ}C\rightarrow25.0^{\circ}C\rightarrow27.5^{\circ}C$. In contrast, the 2nd group of rice cultivars exhibited eliminable vegetative phase slowly decreasing when the temperature changed from $22.5^{\circ}C\rightarrow25.0^{\circ}C\rightarrow27.5^{\circ}C$, but rapidly decreasing when the mean temperature changed from $20.0^{\circ}C\;to\;22.5^{\circ}C$. All the cultivars belonged to 2nd group, the heading date would be very delayed if cool summer comes.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application (PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석)

  • Park, Kyeongjin;Kim, Hyoungtaek;Lim, Kyungtaek;Cho, Minsik;Kim, Giyoon;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF