• Title/Summary/Keyword: phantom-node method

Search Result 6, Processing Time 0.016 seconds

The Phantom-node Method for Cracked Problems in Shell Structures

  • Zi, Goang-Seup;Chau-Dinh, Thanh;Lee, Phill-Seung;Kim, Ji-Hwan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.207-210
    • /
    • 2010
  • This paper presents an method, called the phantom-node method, for representing discontinuities in shell structures. By decomposing an element completely cut by a crack into two overlapped elements special treatment of the MITC3 shell element to overcome "locking phenomenon" is straightforward. Two numerical examples are provided.

  • PDF

Image Fusion of Lymphoscintigraphy and Real images for Sentinel Lymph Node Biopsy in Breast Cancer Patients (유방암 환자의 감시림프절 생검을 위한 림포신티그라피와 실사영상의 합성)

  • Jeong, Chang-Bu;Kim, Kwang-Gi;Kim, Tae-Sung;Kim, Seok-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.114-122
    • /
    • 2010
  • This paper presents a method that registers a lymphoscintigraphy to the real image captured by a CMOS camera, which helps surgeons to easily and precisely detect sentinel lymph nodes for sentinel lymph node biopsy in breast cancer patients. The proposed method consists of two steps: pre-matching and image registration. In the first step, we localize fiducial markers in a lymphoscintigraphy and a real image of a four quadrant bar phantom by using image processing techniques, and then determines perspective transformation parameters by matching with the corresponding marker points. In the second step, we register a lymphoscintigraphy to a real images of patients by using the perspective transformation of pre-matching. To examine the accuracy of the proposed method, we conducted an experiment with a chest mock-up with radioactive markers. As a result, the euclidean distance between corresponding markers was less than 3mm. In conclusion, the present method can be used to accurately align lymphoscintigraphy and real images of patients without attached markers to patients, and then provide useful anatomical information on sentinel lymph node biopsy.

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

Routing for Enhancing Source-Location Privacy in Wireless Sensor Networks of Multiple Assets

  • Tscha, Yeong-Hwan
    • Journal of Communications and Networks
    • /
    • v.11 no.6
    • /
    • pp.589-598
    • /
    • 2009
  • In wireless sensor networks, a node that reports information gathered from adjacent assets should relay packets appropriately so that its location context is kept private, and thereby helping ensure the security of the assets that are being monitored. Unfortunately, existing routing methods that counter the local eavesdropping-based tracing deal with a single asset, and most of them suffer from the packet-delivery latency as they prefer to take a separate path of many hops for each packet being sent. In this paper, we propose a routing method, greedy perimeter stateless routing-based source-location privacy with crew size w (GSLP-w), that enhances location privacy of the packet-originating node (i.e., active source) in the presence of multiple assets. GSLP-w is a hybrid method, in which the next-hop node is chosen in one of four modes, namely greedy, random, perimeter, and retreat modes. Random forwarding brings the path diversity, while greedy forwarding refrains from taking an excessively long path and leads to convergence to the destination. Perimeter routing makes detours that avoid the nodes near assets so that they cannot be located by an adversary tracing up the route path. We study the performance of GSLP-w with respect to crew size w (the number of packets being sent per path) and the number of sources. GSLP-w is compared with phantom routing-single path (PR-SP), which is a notable routing method for source-location privacy and our simulation results show that improvements from the point of the ratio of safety period and delivery latency become significant as the number of source nodes increases.

Simulation of Multi-Cracking in a Reinforced Concrete Beam by Extended Finite Element Method (확장유한요소법을 이용한 철근 콘크리트 보의 다중균열 해석)

  • Yoo, Hyun-Suk;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2016
  • Recently, extensive research on crack analysis using extended finite element method(XFEM) which has main advantages in element re-meshing and visualization of cracks has been conducted. However, its application was restricted to the members of a single material. In this study, the applicability and feasibility of the XFEM to the multiple crack analysis of reinforced concrete beams were demonstrated. ABAQUS which has implemented XFEM was used for the crack analysis and its results were compared with test results. Enriched degree-of-freedom locking phenomenon was discovered and its causes and the ways to prevent it were suggested. The locking occurs when cracks in the adjacent elements simultaneously develop. A modelling technique for multiple cracking similar to test results was also proposed. The analysis with XFEM showed similar results to the tests in terms of crack patterns, spacing of cracks, and load-deflection relationship.

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF