• Title/Summary/Keyword: phantom model

Search Result 246, Processing Time 0.032 seconds

Trends in Acupuncture Training Research: Focus on Practical Phantom Models

  • Jang, Jung Eun;Lee, Yeon Sun;Jang, Woo Seok;Sung, Won Suk;Kim, Eun-Jung;Lee, Seung Deok;Kim, Kyung Ho;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • v.39 no.2
    • /
    • pp.77-88
    • /
    • 2022
  • The purpose of this review was to identify research trends in acupuncture training systems and models and to analyze acupuncture training using phantom models. Articles on acupuncture training were retrieved from domestic and foreign electronic databases (PubMed, CNKI, CiNii, NDSL, KISS, RISS and KMBase). The search included studies conducted from January 1, 2010 to October 1, 2021. Acupuncture training was analyzed by categorization into acupoint location training and needling training. Acupuncture training was most frequently studied in China, acupoint location training was the most studied in 2012, and needling training was the most studied in 2013 and 2020. Among them, a silicone model with a sensor was used for training in acupoint location, and silicone and agarose gel were frequently used for needling training. Classifications of the phantom models for needling training by topic included phantom development, phantom-based education and evaluation system, phantom-based quantitative measurement, comparison of kinematic characteristics of hand motion between experts and beginners, and phantom models for acupoint location and needling training. Further research on the development of acupuncture practice training systems to improve practical skills is needed.

Making Human Phantom for X-ray Practice with 3D Printing (3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • General phantom for practical X-ray photography Practical phantom is an indispensable textbook for radiology, but it is difficult for existing commercially available phantom to be equipped with various kinds of phantom because it is an expensive import. Using 3D printing technology, I would like to make the general phantom for practical X-ray photography less expensive and easier. We would like to use a skeleton model that was produced based on CT image data using a 3D printer of FDM (Fused Deposition Modeling) method as a phantom for general X-ray imaging. 3D slicer 4.7.0 program is used to convert CT DICOM image data into STL file, convert it to G-code conversion process, output it to 3D printer, and create skeleton model. The phantom of the completed phantom was photographed by X - ray and CT, and compared with actual medical images and phantoms on the market, there was a detailed difference between actual medical images and bone density, but it could be utilized as a practical phantom. 3D phonemes that can be used for general X-ray practice can be manufactured at low cost by utilizing 3D printers which are low cost and distributed and free 3D slicer program for research. According to the future diversification and research of 3D printing technology, it will be possible to apply to various fields such as health education and medical service.

Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

  • Choi, Da-Hye;Choi, Bo-Ram;Choi, Jin-Woo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.43 no.1
    • /
    • pp.7-15
    • /
    • 2013
  • Purpose: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. Materials and Methods: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. Result: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Conclusion: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

The Theoretical Study of Absorbed Dose Distributions in Water Phantom Irradiated by High Energy Photon Beam (물팬톰에 조사된 고에너지 광자선의 선량 분포 특성에 관한 이론적 고찰)

  • 최동락;이명자
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.75-84
    • /
    • 1990
  • We have claculated the absorbed dose distributions in water phantom irradiated by high energy photon beam. PDD (Percent Depth Dose) and Beam Profile can be represented by functions of depths and distances by using one dimensional model model based on transport theory. The parameters on scattering and absorption are evaluated by using non-linear regression process method. The values neeessary for calculation are obtained by simple experiment. The calculated values are in good agreement with the measured values.

  • PDF

A Study on Spectra of Laser Induced Fluorescence in Phantom (Phantom에서 Laser Induced Fluorescence의 스펙트라에 관한 연구)

  • Kim, Ki-Jun;Sung, Ki-Chun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.329-335
    • /
    • 1999
  • The influences of fluorophor, scatterer, and absorber in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength. The molecular properties have been studied by laser induced fluorescence spectroscopy in phantom. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_a$, ${\mu}_a$, ${\mu}_t$). Experimental and Monte Carlo Simulation method for modelling light transport in tissue was applied. The experimental results using a phantom were discussed and compared with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for oil chemistry, medicine and application of medical engineering.

A new phantom to evaluate the tissue dissolution ability of endodontic irrigants and activating devices

  • Kimia Khoshroo ;Brinda Shah;Alexander Johnson ;John Baeten ;Katherine Barry;Mohammadreza Tahriri ;Mohamed S. Ibrahim;Lobat Tayebi
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.45.1-45.8
    • /
    • 2020
  • Objective: The aim of this study was to introduce a gelatin/bovine serum albumin (BSA) tissue standard, which provides dissolution properties identical to those of biological tissues. Further, the study evaluated whether the utilization of endodontic activating devices led to enhanced phantom dissolution rates. Materials and Methods: Bovine pulp tissue was obtained to determine a benchmark of tissue dissolution. The surface area and mass of samples were held constant while the ratio of gelatin and BSA were varied, ranging from 7.5% to 10% gelatin and 5% BSA. Each sample was placed in an individual test tube that was filled with an appropriate sodium hypochlorite solution for 1, 3, and 5 minutes, and then removed from the solution, blotted dry, and weighed again. The remaining tissue was calculated as the percent of initial tissue to determine the tissue dissolution rate. A radiopaque agent (sodium diatrizoate) and a fluorescent dye (methylene blue) were added to the phantom to allow easy quantification of phantom dissolution in a canal block model when activated using ultrasonic (EndoUltra) or sonic (EndoActivator) energy. Results: The 9% gelatin + 5% BSA phantom showed statistically equivalent dissolution to bovine pulp tissue at all time intervals. Furthermore, the EndoUltra yielded significantly more phantom dissolution in the canal block than the EndoActivator or syringe irrigation. Conclusions: Our phantom is comparable to biological tissue in terms of tissue dissolution and could be utilized for in vitro tests due to its injectability and detectability.

A Verification of the Accuracy of the Deformable Model in 3 Dimensional Vessel Surface Reconstruction (혈관표면의 3차원 재구성을 위한 Deformable model의 정확성 검증에 관한 연구)

  • Kim, H.C.;Oh, J.S.;Kim, H.R.;Cho, S.B.;Sun, K.;Kim, M.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.3-5
    • /
    • 2005
  • Vessel boundary detection and modeling is a difficult but a necessary task in analyzing the mechanics of inflammation and the structure of the microvasculature. In this paper we present a method of analyzing the structure by means of an active contour model(using GVF Snake) for vessel boundary detection and 3D reconstruction. For this purpose we used a virtual vessel model and produced a phantom model. From these phantom images we obtained the contours of the vessel by GVF Snake and then reconstructed a 3D structure by using the coordinates of snakes.

  • PDF

An Empirical Study on the Detection of Phantom Transaction in Online Auction (온라인 경매에의 카드깡 탐지요인에 대한 실증적 연구)

  • Chae Myeong-Sin;Jo Hyeong-Jun;Lee Byeong-Chae
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.68-98
    • /
    • 2004
  • Although the internet is useful for transferring information, Internet auction environments make fraud more attractive to offenders because the chance of detection and punishment are decreased. One of fraud is phantom transaction which is a colluding transaction by the buyer and seller to commit illegal discounting of credit card. They pretend to fulfill the transaction paid by credit card, without actual selling products, and the seller receives cash from credit card corporations. Then seller lends it out buyer with quite high interest rate whose credit score is so bad that he cannot borrow money from anywhere. The purpose of this study is to empirically investigate the factors to detect of the phantom transaction in online auction. Based up on the studies that explored behaviors of buyers and sellers in online auction, bidding numbers, bid increments, sellers' credit, auction length, and starting bids were suggested as independent variables. We developed an Internet-based data collection software agent and collect data on transactions of notebook computers each of which winning bid was over 1,000,000 won. Data analysis with logistic regression model revealed that starting bids, sellers' credit, and auction length were significant in detecting the phantom transaction.

  • PDF

An Empirical Study on the Detection of Phantom Transaction in Online Auction (온라인 경매에서의 신용카드 허위거래 탐지 요인에 대한 실증 연구)

  • Chae Myungsin;Cho Hyungjun;Lee Byungtae
    • Korean Management Science Review
    • /
    • v.21 no.2
    • /
    • pp.273-289
    • /
    • 2004
  • Although the Internet is useful for transferring information, Internet auction environments make fraud more attractive to offenders, because the chance of detection and punishment is decreased. One of these frauds is the phantom transaction, which is a colluding transaction by the buyer and seller to commit the illegal discounting of a credit card. They pretend to fulfill the transaction paid by credit card, without actually selling products, and the seller receives cash from the credit card corporations. Then the seller lends it out with quite a high interest rate to the buyer, whose credit rating is so poor that he cannot borrow money from anywhere else. The purpose of this study is to empirically investigate the factors necessary to detect phantom transactions in an online auction. Based upon studies that have explored the behaviors of buyers and sellers in online auctions, the following have been suggested as independent variables: bidding numbers, bid increments, sellers' credit, auction lengths, and starting bids. In this study. we developed Internet-based data collection software and collected data on transactions of notebook computers, each of which had a winning bid of over W one million. Data analysis with a logistic regression model revealed that starting bids, sellers' credit, and auction length were significant in detecting the phantom transactions.

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.