• Title/Summary/Keyword: permeable surface

Search Result 188, Processing Time 0.027 seconds

A Study on Temperature Change Profiles by Land Use and Land Cover Changes of Paddy Fields in Metropolitan Areas (대도시 외곽지역 논경작지의 토지이용 및 피복변화에 따른 온도 변화모형 연구)

  • Ki, Kyong-Seok;Lee, Kyong-Jae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • The purpose of this study is to understand the scale of temperature change following large-scale urban developments in paddy fields to present possible measures to preserve suburban area paddy fields and to lower the scale of temperature increase after developing paddy fields in urban areas. The study was conducted in Bupyeong and Bucheon of Incheon Metropolitan City. The satellite image($1989{\sim}2000$) before and after the development of old paddy fields were used to analyze the land surface temperature changes according to the land use types. Building coverage, green coverage, non-permeable pavement coverage, and floor area ratio(FAR) were selected as the factors that influence urban temperature changes and the temperature estimation model was constructed by using correlation and regression analyses. The before and after satellite images of Bupyeong and Bucheon were classified into forests, greens and plantations, paddy fields, unused lands, and urban areas. The results indicate that most of the paddy fields that existed in the center of Bupyeong and Bucheon were converted into unused lands which were undergoing construction to become new urban areas. The difference between the surface temperatures of May 17th, 1989 and May 7th, 2000 was analyzed to reveal that most land converted from paddy fields to unused lands or urban areas saw an increase in surface temperature. Han River was used as a comparison to analyze the average surface temperature changes($1989{\sim}2000$) in former paddy fields. The scale of temperature changes were: $+1.6697^{\circ}C$ in urban parks; $+2.5503^{\circ}C$ in residential zones; $+2.9479^{\circ}C$ on public lands, $+3.0385^{\circ}C$ in commercial zones, and $+3.1803^{\circ}C$ in educational zones. The correlation between building coverage, green coverage, non-permeable pavement coverage, or floor area ratio(FAR) and surface temperature increases was also analyzed. The green coverage to temperature increases, but building coverage, non-permeable pavement coverage, and floor area ratio(FAR) had no statistically significant temperature increases. The factors that influence urban temperature changes were set up as independent variables and the surface temperature changes as dependent variables to construct a surface temperature change model for the land use types of former paddy fields. As a result of regression analysis, green coverage was selected as the most significant independent variable. According to regression analysis, if farmland is converted into an urban area, a temperature increase of $+3.889^{\circ}C$ is anticipated with 0% green coverage. The temperature saw a decrease of $-0.43^{\circ}C$ with every 10% increase of green coverage.

A Study on the Surface Air-Void Reduction of High Performance Concrete (고성능 콘크리트의 표면기포 저감에 관한 연구)

  • Park, Sang-Joon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • In this study, reduction methods of surface air void were examined for high performance concrete having high viscosity. The effects of assumed influencing factors such as form types, form-coating materials, tamping equipments and methods were examined based on the tests on mock-up specimens made of high performance concrete. The test results can be summarized as follows: As for form types, the most favorable results were obtained when coated plywood form was used with panel-shape tamping equipments at the contact region with concrete, the second and the third being the water/air-permeable sheets and steel with coated plywood, respectively. As for tamping equipments, a vibrator with 6.5cm diameter was most effective. Finally, the shorter the tamping intervals, the better the reduction effect of surface air void. As a conclusion, an improved method was proposed to reduce surface air void and it was verified with the test result that only four air voids as large as $5{\sim}10mm$ are found in the are of $1m^2$.

Internal Atmosphere of Individual Sweet Persimmon Package as Function of Fruit Size and Package Film Area (과일 크기와 포장 표면적에 따른 낱개 단감 포장의 기체조성)

  • Kim, Hae-Jin;Ahn, Gwang-Hwan;Jeong, Mi-Jin;An, Duck-Soon;Lee, Dong-Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.2_3
    • /
    • pp.53-58
    • /
    • 2010
  • Internal gas composition of single unit persimmon package was evaluated at $-1^{\circ}C$ as function of package film area and fruit weight in order to find packaging conditions to achieve the optimal modified atmosphere beneficial for keeping the freshness. With large fruit size(${\approx}230\;g$), low permeable films (LLDPE/PP in 35 or $40\;{\mu}m$ thickness and $30\;{\mu}m$ OPP) with an exact fitness to the fruit (surface area of $0.040\;m^2$) resulted in anaerobic atmosphere with occurrence of browning in long term storage. With medium (${\approx}210\;g$) and medium small (${\approx}190g$) sizes, larger surface area of low permeable $35\;{\mu}m$ LLDPE/PP film provided higher $O_2$ and lower $CO_2$ concentrations causing higher occurrence of softening and blackening discoloration. On the other hand, smaller surface area of lower $O_2$ and higher $CO_2$ concentrations had a high risk of browning. Wise combination of fruit size, packaging film and surface area is required for attaining the beneficial modified atmosphere to prevent the physiological injuries.

  • PDF

A Study on Properties of Retentive Asphalt Concrete (보수성 아스팔트 콘크리트의 특성에 관한 연구)

  • Jang, Seck-Soo;Lee, Seung-Han;Jung, Yong-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.565-568
    • /
    • 2006
  • This study was retentive material into the porosities of the permeable asphalt concrete, we developed retentive asphalt concrete which can absorb water in rain and decrease the temperature of the pavement through the vaporization of rainwater. The experimental results showed that the maximum stability appeared in the 5.0% types of both AP-5 and SBS PMA. Between these two types, the maximum stability of the asphalt with AP-5 was 480kg, which means it met the stability requirement for walkways but didn't meet the requirement for roadways. On the other hand, the maximum stability of the asphalt concrete with SBS PMA was 676kg, which was 176 kg higher than the requirement for roadways(500kg) and satisfy the requirement of KS. The retentive material was 56.4% in the type of the retentive material with 30% diatomaceous earth, 66.6% in 50% type, 87.5% in 70% type. In the aspect of thermal properties, the retentive asphalt concrete can lower the surface temperature by about 15 degrees lower than the normal asphalt concrete can. This effect could be made by the evaporation cooling effect and the surface albedo. It should be noted that the evaporation cooling effect cools it by about 10 degrees and the surface albedo by about 5 degrees.

  • PDF

Enhanced Activity of Phenylalanine Ammonia Lyase in Permeabilised Recombinant E. coli by Response Surface Method

  • Cui, Jian-dong;Li, Yan;Jia, Shi-Ru
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.494-499
    • /
    • 2009
  • To improve phenylalanine ammonia lyase (E.C.4.3.1.5-PAL) activity in recombinant Escherichia coli, Some approaches for improving phenylalanine ammonia lyase (PAL) activity in recombinant E. coli were developed following preliminary studies by means of response surface method. The results shown that permeabilization with combination of Triton X-100, cetyl trimethyl ammonium bromide (CTAB), and acetone enriched cellular recombinant PAL activity significantly, which improved over 10-fold as compared with the control (untreat cell), as high as 181.37 U/g. The optimum values for the tested variables were Triton X-100 0.108 g/L, CTAB 0.15 g/L, and acetone 45.2%(v/v). Furthermore, a second-order model equation was suggested and then validated experimentally. It was indicated that addition of surfactants and organic solvents made the cells more permeable and therefore allowed easier access of the substrate to the enzyme and excretion of the product, which increased the rate of transport of L-phenylalanine and trans-cinnamic acids. These improved methods of PAL activity enrichment could serve as a rich enzyme source, especially in the biosynthesis of L-phenylalanine.

Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV (FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석)

  • Lee, J.M.;Jeong, J.H.;Chon, M.S.;Lee, H.W.
    • Transactions of Materials Processing
    • /
    • v.27 no.1
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

The Effects of Plasma Surface Treatment on Fluorosilicone Acrylate RGP Contact Lenses (불화규소 아크릴레이트 RGP 콘택트렌즈의 플라즈마 표면처리 효과)

  • Jang, Jun-Kyu;Shin, Hyung-Sup
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.207-212
    • /
    • 2010
  • Purpose: Rigid gas permeable (RGP) contact lenses, based on fluorosilicone acrylate, were treated with plasma in air. Methods: The chemical compositions were analyzed by using X-ray photoelectron spectroscopy (XPS), the surface morphology and roughness of RGP contact lenses were observed by using atomic force microscopy (AFM), and the wettability changes were estimated by wetting angle measurement. Results: As the contact lenses were treated by the plasma, the F contents decreased significantly, and the O and Si contents increased on the surface. The number of oxygen-containing hydrophilic radicals (C-O and Si-O) increased greatly, the hydrophobic surface decreased, and the wetting angle increased. But the C-O bonds created with exchange of the fluorine did not increase a wettability. The surface compositions were not remarkably changed for the 6 months after plasma treatment, but the wetting angle increased again. Conclusions: It was considered that the improved wettability of the RGP contact lenses of high fluorine content after plasma treatment was affected by the activation of surface, the increase of Si-O, and the decrease of hydrophobic surface.

Numerical investigation on cavitation and non-cavitation flow noise on pumpjet propulsion (펌프젯 추진기의 공동 비공동 유동소음에 대한 수치적 연구)

  • Garam Ku;Cheolung Cheong;Hanshin Seol;Hongseok Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.250-261
    • /
    • 2023
  • In this study, the noise contributions by the duct, stator and rotor, which are the propulsor components, are evaluated to identify the flow noise source in cavitation and non-cavitation conditions on pumpjet propulsion and the noise levels in both conditions are compared. The unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equation based on the homogeneous mixture assumption is applied on the suboff submarine hull and pumpjet propeller in the cavitation tunnel, and the Volume of Fluid (VOF) method and Schnerr-Sauer cavitation model are used to describe the two-phase flow. Based on the flow simulation results, the acoustic analogy formulated by Ffowcs Williams and Hawkings (FW-H) equation is applied to predict the underwater radiated noise. The noise contributions are evaluated by using the three types of impermeable integral surface on the duct, stator and rotor, and the two types of permeable integral surface surrounding the propulsor. As a result of noise prediction, the contribution by the stator is insignificant, but it affects the generation of flow noise source due to flow separation in the duct and rotor, and the noise is predominantly radiated into the upward and right where the flow separations are. Also, the noise is radiated into the thrust direction due to pressure fluctuation between suction and pressure sides on the rotor blades, and the it can be seen that the cavitation effect into the noise can be considered through the permeable integral surface.

Moisture and Heat Transfer Characteristics of Waterproof and Water Vapor Permeable Coated Fabrics (기능성 투습방수 코팅포의 수분 및 열전달 특성)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.151-163
    • /
    • 1999
  • The purpose of this study was to investigate the thermal resistance and the liquid/vapor water transfer characteristics of four waterproof and water vapor permeable coated fabrics with the ground fabric called nylon taffeta. In order to establish the experimental environment, outdoor temperature and humidity in Taegu during the last three years were examined and the experiment was performed at (1) $15^{\circ}C$, 50% R.H., (2) $20^{\circ}C$, 60% R.H., (3) $25^{\circ}C$, 65% R.H., which were the average standards in spring and fall. The test results were as follows ; 1. Among physical parameters, the thinner the thickness was, the higher the water vapor permeability was. But the porosity in thickness was not proportional to water vapor permeability linearly. 2. The thicker the thickness of specimens was and the smaller the bulk density and porosity were, the higher the thermal resistance. And the results also shown that the larger the temperature difference between the environmental temperature and the hot plate was, the more the difference of CLO values was apparent. 3. Since the contact angle of all specimens are above $90^{\circ}$, the all specimens have a good performance in waterproof. The more the specimens surface were rough, the higher the thermal resistance was. 4. According to the result of performing moisture transfer test using the simulating body skin-clothing-environment system, the humidity sensor placed in between the fabric and the environment detected the full saturation in 10 minutes after the experiment had began at $15^{\circ}C$, 50% R.H. and in 15 minutes after the experiment both at $20^{\circ}C$, 60% R.H. and at $25^{\circ}C$, 65% R.H. 5. ${\Delta}$ values of the humidity sensors placed in between the human body and the fabric and in between the fabric and the environment fluctuated repeatedly within the range of $20{\sim}40%$ at $20^{\circ}C$, 60% R.H., and $15{\sim}30%$ at $25^{\circ}C$, 65% R.H.

  • PDF

Characteristics of Wall Pressure over Wall with Permeable Coating (침투성 코팅 처리된 벽면 주위의 벽 압력 특성)

  • Song, Woo-Seog;Shin, Seung-Yeol;Lee, Seung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1055-1063
    • /
    • 2012
  • Fluctuating wall pressures were measured using an array of 16 piezoelectric transducers beneath a turbulent boundary layer. The coating used in this experiment was an open-cell, urethane-type foam with a porosity of approximately 50 ppi. The ultimate objective of the coating is to provide a mechanical filter to reduce the wall pressure fluctuations. The boundary layer on the flat plate was measured by using a hot wire probe, and the CPM method was used to determine the skin friction coefficient. The wall pressure autospectra and streamwise wavenumber-frequency spectra were compared to assess the attenuation of the wall pressure field by the coating. The coating is shown to attenuate the convective wall pressure energy. However, the relatively rough surface of the coating in this investigation resulted in a higher mean wall shear stress, thicker boundary layer, and higher low-frequency wall pressure spectral levels compared to a smooth wall.