• 제목/요약/키워드: permanent.

검색결과 6,694건 처리시간 0.032초

한국인 영구중절치의 단계별 붕출시기에 관한 연구 (A Study on the Eruption Time of Permanent Central Incisor with the Eruption Phases in Korean)

  • 김영구
    • Journal of Oral Medicine and Pain
    • /
    • 제4권1호
    • /
    • pp.22-30
    • /
    • 1979
  • In order to evaluate the normal eruption time of Korean permanent teeth, the uthor had examined the eruption phases of permanent central incisors in 714 malw and 581 female children aged from 4.5 to 9-year old and analysed. The eruption was divided into 3 phases; the tip of crown can be seen, the half of the crown can be easily seen, and full length of the crown can be seen. The obtained results were as follows : 1. It seemed that percentage of the erupting and erupted permanent central incisor in female by age was higher than that of male. 2. In general, percentage of the erupting and erupted lower central incisor by age was higher than that of upper first molar.

  • PDF

ECC 영구거푸집의 내화성능 및 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Fire Resistance and Mechanical Properties of ECC Permanent Form)

  • 김용로;송영찬;오재근;김재환;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.75-78
    • /
    • 2009
  • It was investigated fire resistance properties and mechanical properties of high strength concrete column using ECC(Engineered Cementitious Composites) permanent form by KS F 2257 Methods of fire resistance test for elements of building construction and compression test for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

영구임대주택 단지내 사회복지관과 관리사무소의 업무 관련 요구 및 문제점 분석을 통한 관리체계 개선방안 (A Study to Improve Management System through the Analysis of Needs and Problems of Community Welfare Center and Management Office in Permanent Public Rental Housing Complex)

  • 김영주;김성천
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.509-514
    • /
    • 2006
  • This study aimed to suggest the implications to improve the management system of permanent public rental housing. For this purpose, qualitative data were collected by using the in-depth interview with 13 staffs of community welfare center and management office in permanent public rental housing complexes and 2 times of advisory committee meetings. To analyze the data gathered in this study, the constant comparative method of data analysis was used. Based on the results, some implications including institutional support and social complementary cooperation were suggested in terms of short and long term period.

  • PDF

영구치 맹출양상에 관한 연구(제1대구치) (The Study of Eruption Process of the Permanent Teeth (First Permenent Molar))

  • 김진태
    • 대한치과의사협회지
    • /
    • 제21권12호통권175호
    • /
    • pp.1005-1010
    • /
    • 1983
  • To study the eruption process of the permanent tooth, esp., 1st molar, the author took 303 cases of oblique cephalogram (Male. 162 cases, Female: 141 cases) from age 3 to 8 yea old children, and observed the vertical change and axial change. The result were as follow: 1. The mesial end of upper 1st molar was closer to the occlusal plane than the distal, and they were erupting toward the occlusal plane by aging. In the case of lower 1st molar, the distal end was closer to the occlusal plane than the mesial and the occlusion showed the tendency to accord with the plane to be settled by aging. 2. Eruption rate of the upper and lower 1st permanent molar increased rapidly at 5 or 6 years of age. 3. Axial inclination of lower 1st permanent molar to the mandibular plane decreased gradually from 3 years of age, except for 6 years of age. There was some increase at 5 or 6 years of age.

  • PDF

Permanent Shotcrete Tunnel Linings 구축을 위한 고성능 숏크리트 개발 II (II: 용수부에서의 조강시멘트 적용) (Development of High Performance Shotcrete for Permanent Shotcrete Tunnel Linings II(II: Application of high-early strength cement in sump water condition))

  • 박해균;이명섭;김재권;안병제
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.695-702
    • /
    • 2002
  • Shotcrete (or Sprayed concrete) has been used as an important support material in New Austrian Tunnelling Method (NATM). Since the mid of 1990, permanent shotcrete tunnel linings such as Single-shell, NMT (Norwegian Method of Tunnelling) has been constructed in many countries for reducing the construction time and lowing construction costs instead of conventional in-situ concrete linings. Among essential technologies for successful application of permanent shotcrcte linings, high performance shotcrete providing high strength, high durability, better pumpability has to be developed in advance as an integral component. This paper presents the Ideas and first experimental attempts to increase early strength and bond strength of wet-mixed Steel Fiber Reinforced Shotcrete(SFRS) in sump water condition. In order to increase early strength, a new approach using high-early strength cement with liquid alkali-free accelerator has been investigated From the results, wet-mix SFRS with high-early strength cement and alkali-free accelerator exhibited excellent early strength improvement compared to the ordinary portland content and good bond strength even under sump water condition.

  • PDF

Support-vector-machine Based Sensorless Control of Permanent Magnet Synchronous Motor

  • Back, Woon-Jae;Han, Dong-Chang;Kim, Jong-Mu;Park, Jung-Il;Lee, Suk-Gyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.149-152
    • /
    • 2004
  • Speed and torque control of PMSM(Permanent Magnet Synchronous Motor) are usually achieved by using position and speed sensors which require additional mounting space, reduce the reliability in harsh environments and increase the cost of a motor. Therefore, many studies have been performed for the elimination of speed and position sensors. In this paper, a novel speed sensorless control of a permanent magnet synchronous motor based on SVMR(Support Vector Machine Regression) is presented. The SVM regression method is an algorithm that estimates an unknown mapping between a system's input and outputs, from the available data or training data. Two well-known different voltage model is necessary to estimate the speed of a PMSM. The validity and the usefulness of proposed algorithm are thoroughly verified through numerical simulation.

  • PDF

영구자석을 이용한 고양이 구치부 intrusion에 관한 초기 조직학적 연구 (AN INITIAL HISTOLOGIC STUDY ON MOLAR INTRUSION OF CAT WITH THE USAGE OF PERMANENT MAGNET)

  • 김승철;유영규
    • 대한치과교정학회지
    • /
    • 제20권1호
    • /
    • pp.169-179
    • /
    • 1990
  • Utilizing the repelling force of permanent magnet of find out weather it shows the findings of molar intrusion histologically and compares the result with the resin bite plane. As for the experimental animals, 10 cats of completion of permanent dentition with mean weight of 2.2kg which have flat occlusal plane of molar areas were used. I raised the cats under the condition of their being attached with manufactured appliance by direct bonding system and of their wearing vertical chin strap anesthetized for 12-14 hours per day through 5 days. Then, observing the root apex areas with lightmicroscope. The results were as follows; 1. In the group with resin bite plane, osteoblasts and osteoclasts could not find out but could find out periodontal ligment fiber obliquely angulated in the apical and lingual direction. 2. In the group with the permanent magnet, not only the obliquely angulated periodontal ligament fiber but also the osteoclasts at the apical areas were observed.

  • PDF

풍화암에 근입된 영구 앵커의 극한인발력 (Ultimate Uplift Capacity of Permanent Anchor Embedded in Weathered Rock)

  • 유남재;박병수;정길수;김진황
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.195-203
    • /
    • 2001
  • The purpose of this study is to estimate ultimate uplift capacity of permanent anchor which was cast into weathered rock. The ultimate uplift capacity was estimated from the load-displacement curve of four different anchors which have different bond length. The creep test was performed for 15minutes under the maximum load of each step in order to understand the load-transfer property of permanent anchor and to decide which anchor to choose. The destruction range of soil due to the changes in load was estimated by installing dial gauge on the ground which was cast into the weathered rock. Ultimately, the study on the behavior of the anchor case into the weathered rock was performed by comparing and analyzing the estimated result of the UUC obtained by the full scale pull out test in the field with the exsting theoretical and practical results of soil and rock anchor.

  • PDF

Analytical Prediction and Experimental Verification of Electromagnetic Performance of a Surface-Mounted Permanent Magnet Motor having a Fractional Slot/Pole Number Combination

  • Hong, Sang-A;Choi, Jang-Young;Jang, Seok-Myeong
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.84-89
    • /
    • 2014
  • This paper presents an analytical prediction and experimental verification of the electromagnetic performance of a parallel magnetized surface-mounted permanent magnet (SPM) motor having a fractional number of slots per pole combination. On the basis of a two-dimensional (2-D) polar coordinate system and a magnetic vector potential, analytical solutions for flux density produced by the permanent magnets (PMs) and stator windings are derived. Then, analytical solutions for back-electromotive force (emf) and electromagnetic torque are derived from these field solutions. The analytical results are thoroughly validated with 2-D nonlinear finite element (FE) analysis results. Finally, the experimental back-emf and electromagnetic torque measurements are presented to test the validity of the analysis.

센서리스 매입형 영구자석 브러시리스 직류전동기 구동장치에서 단순화된 회전자 위치검출 오차 분석 방법 (A Simplified Analysis Approach on the Rotor Position Detection Error in Sensorless Interior Permanent Magnet Brushless DC Motor Drives)

  • 이광운;박태식
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.449-452
    • /
    • 2016
  • This paper presents a simplified analysis on the rotor position detection error in sensorless interior permanent magnet brushless DC motor (BLDCM) drives, wherein terminal voltage sensing based on the back-electromotive force (back-EMF) zero-crossing point detecting circuitry is employed. The effect of a rotor saliency on the back-EMF's zero-crossing point detection is analyzed using the extended EMF-based voltage equation of the interior permanent BLDCM in a stationary reference frame, and thus the overall analysis is considerably simplified compared to the conventional one. Simulation results are provided to verify the effectiveness of the proposed method.