• 제목/요약/키워드: performance tests and methods

검색결과 1,110건 처리시간 0.032초

프리캐스트 콘크리트 모듈러 개발 및 현장적용에 관한 연구 (A Study on the Development of Precast Concrete Modular and its Application Onsite)

  • 배규웅;부윤섭;신상민
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.27-28
    • /
    • 2023
  • Currently, the Off-Site Construction (OSC) construction method, which emphasizes the minimization of field work, is being emphasized at construction sites due to the lack of construction skilled manpower, extreme weather, and the Severe Disaster Punishment Act. In this study, we developed a stacked PC modular, which is a method of stacking PC modules, and solved the lifting problem by reducing the weight of the unit module, which is emerging as the biggest disadvantage of PC modules, to around 20 tons. For the connection between modules, structural safety was secured through repeated history tests of the wall and slab connection. Walls and slabs satisfied all statutory fire resistance times through fire resistance tests, and residential performance was evaluated to be satisfactory through mock-up demonstration. The developed PC modular has been applied to the construction of commercial houses, detached houses, shopping malls, churches, etc., and has design results for many buildings such as dormitories, detached houses with 4 floors or more, and resorts, so it is expected that an atmosphere of revitalization of construction methods will be created.

  • PDF

Refined finite element modelling of circular CFST bridge piers subjected to the seismic load

  • Faxing Ding;Qingyuan Xu;Hao Sun;Fei Lyu
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.643-658
    • /
    • 2024
  • To date, shell-solid and fibre element model analysis are the most commonly used methods to investigate the seismic performance of concrete-filled steel tube (CFST) bridge piers. However, most existing research does not consider the loss of bearing capacity caused by the fracture of the outer steel tube. To fill this knowledge gap, a refined finite element (FE) model considering the ductile damage of steel tubes and the behaviour of infilled concrete with cracks is established and verified against experimental results of unidirectional, bidirectional cyclic loading tests and pseudo-dynamic loading tests. In addition, a parametric study is conducted to investigate the seismic performance of CFST bridge piers with different concrete strength, steel strength, axial compression ratio, slenderness ratio and infilled concrete height using the proposed model. The validation shows that the proposed refined FE model can effectively simulate the residual displacement of CFST bridge piers subjected to highintensity earthquakes. The parametric analysis indicates that CFST piers hold sufficient strength reserves and sound deformation capacity and, thus, possess excellent application prospects for bridge construction in high-intensity areas.

HMM-Based Transient Identification in Dynamic Process

  • Kwon, Kee-Choon
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제2권1호
    • /
    • pp.40-46
    • /
    • 2000
  • In this paper, a transient identification based on a Hidden Markov Model (HMM) has been suggested and evaluated experimentally for the classification of transients in the dynamic process. The transient can be identified by its unique time dependent patterns related to the principal variables. The HMM, a double stochastic process, can be applied to transient identification which is a spatial and temporal classification problem under a statistical pattern recognition framework. The HMM is created for each transient from a set of training data by the maximum-likelihood estimation method. The transient identification is determined by calculating which model has the highest probability for the given test data. Several experimental tests have been performed with normalization methods, clustering algorithms, and a number of states in HMM. Several experimental tests have been performed including superimposing random noise, adding systematic error, and untrained transients. The proposed real-time transient identification system has many advantages, however, there are still a lot of problems that should be solved to apply to a real dynamic process. Further efforts are being made to improve the system performance and robustness to demonstrate reliability and accuracy to the required level.

  • PDF

Edge 정보에 근거한 피라미드 영상부호화 (Pyramidal Image Coding using Edge Information)

  • 김해성;김남철;심영석
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1987년도 춘계학술발표회 논문집
    • /
    • pp.27-30
    • /
    • 1987
  • Some modification of laplacian pyramidal coding have been done and tested for a test image, From our studies, its apperar that 3-D redictor which exploits inter and intra plane redundancy simultaneously somewhat imporves the image quality, We also have tried to reduce the bit rate by only sending zeroth plane image values that correstpond to estimated dege points which can be obtained from the first plane For both cases the feedback of quantization errof in the previous plane has been in the reconstruction of each plane. Subjective and SNR tests show the better performance of the studied methods oner the conventional one.

  • PDF

철도신호설비용 서지보호기에 대한 규격 검토 (The Review of Specification for SPDs used in Railway Signalling Equipment)

  • 이태훈;박기범;전용주;류영태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.596-602
    • /
    • 2008
  • Recently, there are increasing social needs for safe operation of trains and comforting for passengers. But lightning surges are responsible for serious disturbances such as damage, permanent degradation or temporary erratic operation of sensitive electronics circuits and systems. The purpose of this paper is to identify the requirements for Surge Protective Devices(SPDs) used in protecting railway signalling system. In this paper, we describes tests and requirements which establish methods for testing SPDs and determining their performance.

  • PDF

벌류트 펌프의 신뢰성 평가에 관한 연구 (Study for the Reliability Evaluation of a Volute Pump)

  • 정동수;이용범;강보식
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.23-29
    • /
    • 2018
  • The objective of this paper is to evaluate the reliability of a volute pump and presents test results through performance and life tests. The performance and life test methods were presented by analyzing the failure modes of the volute pump. Zero failure test time was calculated to evaluate the reliability of the volute pump and then, the test was performed under accelerated conditions. The test was also carried out to check the failure modes of the field conditions. This study can be provided to improve the product reliability through failure analysis of the volute pump. And failure cause of typical failure case has been investigated and improvement design has been presented. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the volute pump.

수술실 간호사의 안전분위기와 피로 수준이 안전이행에 미치는 영향 (The Impact of Safety Climate and Fatigue on Safety Performance of Operating Room Nurses)

  • 최유은;김현영
    • 간호행정학회지
    • /
    • 제22권5호
    • /
    • pp.471-479
    • /
    • 2016
  • Purpose: This study was conducted to evaluate the level of safety climate, fatigue, and safety performance and to identify the impact of safety climate and fatigue on the safety performance of operating room nurses. Methods: The study design was a descriptive survey. Participants were 174 operating room nurses from two general hospitals and two university hospitals in S and D cities. Three structurally designed questionnaires were used to evaluate their safety climate, fatigue, and safety performance. Collected data were analyzed using descriptive analysis, t-tests, ANOVAs, Pearson correlation coefficient, and stepwise multiple regression. Results: Safety performance of operating room nurses had a mean of 3.26 on a 5-point scale. 'Current department career'(${\beta}=.17$, p=.006) and 'safety climate (work-unit contribution) (${\beta}=.63$, p<.001) accounted for 39% of the variance in operating room nurses' safety performance. Conclusion: Findings indicate that work-unit contribution towards safety climate is an important factor in increasing operating room nurses' safety performance. Therefore, it is essential to find motivational properties consistent with the characteristics of the operating room environment.

지진동을 받는 안벽 구조물의 내진 성능 평가 (Evaluation of Seismic Performance of Quay Walls during Earthquakes)

  • 김성렬
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.112-119
    • /
    • 2000
  • the shaking table tests for 5 different model sections are performed to investigate the behaviors of quay walls during earthquakes and to evaluate the seismic performance of quay walls with countermeasures. 5 different model sections describe the cases of dense soil and loose soil in the foundation repectively the case to which gravel backfill was applied and the cases to which light material replacement method and sand compction pile method was applied repectively for sesmic countermeasure methods. Pore water pressures accelerations and deformations in quay walls and grounds are analyzed. As a result the softening of foundation and backfill soils have much influence on the behaviors of quay walls. Also light material replacement method and sand compaction pile method are effective in improving the seismic performance of quay walls.

  • PDF

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • 멤브레인
    • /
    • 제1권1호
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

Long-term Mechanical Behavior of CFRP-strengthened Steel Members for a Truss Tower

  • Nakamoto, Daiki;Yoresta, Fengky Satria;Matsui, Takayoshi;Mieda, Genki;Matsuno, Kazunari;Matsumoto, Yukihiro
    • 국제초고층학회논문집
    • /
    • 제9권4호
    • /
    • pp.343-349
    • /
    • 2020
  • This research aimed to clarify the long-term mechanical performance of a steel truss member strengthened by a carbon fiber-reinforced polymer (CFRP) without protective coating through exposure testing. Strengthening and repair methods using CFRP have been developed in recent years; however, there is a lack of durability research for CFRP-strengthened members, especially mechanical performance investigation according to actual exposure testing. In this study, 10 CFRP-strengthening steel specimens were created in 2015, and elastic bending tests were conducted biannually. Eventually, although resin loss occurred due to environmental effects, the mechanical performance of CFRP-strengthened steel was not degraded, and we propose a calculation method of bending stiffness to evaluate the lower value of stiffness for design.