  • We have developed a high performance vertical alignment TFT-LCD, that shows a high light transmittance, and wide viewing angle characteristics with an unusually high contrast ratio. In order to optimize the electro-optical properties we have studied the effect of cell parameters, multi-domain structure and retardation film compensation. With the optimized cell parameters and process conditions, we have achieved a 24" wide UXGA TFT-LCD monitor (16:10 aspect ratio 1920X1200) showing a contrast ratio over 500:1, panel transmittance near 4.5%, response time near 27 ms, and viewing angle higher than 80 degree in all directions.

  • PDF

Internet Based Remote Operation and Monitoring System for Machining Equipments (가공설비의 인터넷 기반 원격 감시 및 조작)

  • 정영수;이교일;한영근
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.183-189
    • /
    • 1999
  • Nowadays advanced manufacturing companies are trying to find a way to check the performance of their production equipments and plants from remote sites. However, it is hard to monitor the status of machine or to check the performance of the processes because the regional limitation of distributed environment. This paper presents research results in the real time monitoring of machining processes and internet_based operation of machining centers via internet, which is implemented using VRML and JAVA.

  • PDF

Performance Improvement of DSRC unit for Automatic Gate Clearance System (자동게이트통관시스템용 DSRC 단말기의 성능 개선)

  • 박상완;정봉식
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.187-190
    • /
    • 2002
  • In this paper, we deal with performance improvement of OBE for automatic gate clearance system by using DSRC network of 5.8GHz ISM band. A data format is improved to represent Rx and Tx information which is need to perform clearance at the gate of container terminal. An error message caused by data discordance is added to Previous data format. A graphic LCD monitor is used to control a character font and use Korean.

  • PDF

Architecture Modeling of a Performance Report Tool for a Cluster System (클러스터 시스템의 성능 레포트 툴의 아키텍처 모델링)

  • Kim, Ki;Choi, Eun-Mi
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.06a
    • /
    • pp.67-71
    • /
    • 2003
  • In order to manage a cluster system that consists of a number servers, management aspects such as configuration management, fault management, performance management, and user management should be considered. Especially, it is necessary to monitor performances for performance and fault management. An agent in each server collects performance counters, status changes, and events occurred in normal or abnormal states. The data collected are delivered to a collector sorter and processed in a report tool for performance analysts and management decision in the cluster system point of view, by detecting fault state and tracing out resource usage, service response, and response, and states until failed. In this paper we propose an architecture modeling of a performance report tool for proactive cluster system management. Some results on a cluster system are presented.

  • PDF

Comparison of Cognitive Task-Directed Motor Control Ability in Younger and Older Subjects (인지적 요소가 포함된 과제 수행 시 젊은 성인과 노인의 동작 조절 비교)

  • Lee, Soo-A;Choi, Jong-Duk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-59
    • /
    • 2017
  • PURPOSE: This study compared cognitive task-directed functional motor control ability for reaching and kicking movements in younger and older adults. METHODS: Subjects were divided into two groups of younger and older adults, with 13 subjects in each group. Subjects were required to perform a dual task combining a functional movement and cognitive component. The task consisted of reaching and kicking movements. Participants performed indicated movements when a target appeared on a monitor. The target randomly appeared on the monitor every 10 seconds. The total performance time (TPT), joint angular velocity (JAV), and muscle activation time were used to evaluate motor control ability. RESULTS: There were significant differences in all evaluation factors in a comparison of younger and older adults (p<.05). TPT was significantly shorter in older adults, and JAV and muscle activation time were significantly slower than that in the younger adult group. Although the results for older adults were within the normal range for functional assessment, their motor control abilities were significantly worse for cognitive tasks compared with those of younger adults. CONCLUSION: The results of this study indicated that a motor control assessment tool using a cognitive task would be helpful in assessment of motor control ability in healthy older adults.

Separate Signature Monitoring for Control Flow Error Detection (제어흐름 에러 탐지를 위한 분리형 시그니처 모니터링 기법)

  • Choi, Kiho;Park, Daejin;Cho, Jeonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.5
    • /
    • pp.225-234
    • /
    • 2018
  • Control flow errors are caused by the vulnerability of memory and result in system failure. Signature-based control flow monitoring is a representative method for alleviating the problem. The method commonly consists of two routines; one routine is signature update and the other is signature verification. However, in the existing signature-based control flow monitoring, monitoring target application is tightly combined with the monitoring code, and the operation of monitoring in a single thread is the basic model. This makes the signature-based monitoring method difficult to expect performance improvement that can be taken in multi-thread and multi-core environments. In this paper, we propose a new signature-based control flow monitoring model that separates signature update and signature verification in thread level. The signature update is combined with application thread and signature verification runs on a separate monitor thread. In the proposed model, the application thread and the monitor thread are separated from each other, so that we can expect a performance improvement that can be taken in a multi-core and multi-thread environment.

Design of the Multimodal Input System using Image Processing and Speech Recognition (음성인식 및 영상처리 기반 멀티모달 입력장치의 설계)

  • Choi, Won-Suk;Lee, Dong-Woo;Kim, Moon-Sik;Na, Jong-Whoa
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.8
    • /
    • pp.743-748
    • /
    • 2007
  • Recently, various types of camera mouse are developed using the image processing. The camera mouse showed limited performance compared to the traditional optical mouse in terms of the response time and the usability. These problems are caused by the mismatch between the size of the monitor and that of the active pixel area of the CMOS Image Sensor. To overcome these limitations, we designed a new input device that uses the face recognition as well as the speech recognition simultaneously. In the proposed system, the area of the monitor is partitioned into 'n' zones. The face recognition is performed using the web-camera, so that the mouse pointer follows the movement of the face of the user in a particular zone. The user can switch the zone by speaking the name of the zone. The multimodal mouse is analyzed using the Keystroke Level Model and the initial experiments was performed to evaluate the feasibility and the performance of the proposed system.

On the Development of Speed Trial Data Measurement and Processing System (속력시운전 데이터 계측 및 분석 시스템 개발)

  • Man-Cheol Han
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.2
    • /
    • pp.22-28
    • /
    • 1994
  • A data acquisition and processing system. using an IBM PC, an AD converter, and a printer, has been developed to monitor rapidly and significantly varying signals. The sister takes live signals and computes and displays the trend of the moving averages of the signals in real time. The system has been applied to monitor the shaft horsepower and revolution and the speed of ships for their speed trial. The reliable interpretation of the measured data using moving average can eliminate unnecessary arguments between the owner and yard on the performance of the newly built ships. Other applications of the system-inspection of engine hunting, providing data for ship maneuvering analysis, vibration data analysis, extending to the ship performance monitoring system-are also demonstrated and discussed.

  • PDF

Design and Implementation of Multi-monitoring System for Motor Pump (모터 펌프를 위한 멀티-모니터링 시스템 설계 및 구현)

  • Kim, Tae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.81-86
    • /
    • 2019
  • According to the needs of many users, motor pumps have been steadily developed and widely used in many industries where fluids are used. Motor pumps are used in a variety of environments, degrading quality and performance. It is becoming important to monitor the condition of motor pumps in order to maintain system performance and increase efficiency. This paper presents the method for effectively monitoring the condition of motor pumps. The designed MMI controller receives the collected data through data logging and output and controls the motor pump with touch screen. Implementing a Wi-Fi monitoring system and SCADA monitoring system based on Ethernet and RS485, user can monitor even if the user is far from the MMI controller without time and space limitation. In addition, by implementing a voice output system, the user can immediately recognize the situation through the sound. Therefore, through the proposed method, multi-monitoring system solves the cause of breakdowns and degradation of motor-pump and gives the possibility of commercialization by providing the convenience of maintenance to users.

Software Risk Management and Cyber Security for Development of Integrated System Remotely Monitoring and Controlling Ventilators (인공호흡기 원격 통합 모니터링 및 제어 시스템 개발을 위한 소프트웨어 위험관리 및 사이버보안)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.99-108
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.