• Title/Summary/Keyword: penetration resistance test

Search Result 408, Processing Time 0.025 seconds

Evaluation of Hydrophobic Performance and Durability of Concrete Coated with Cellulose Nanofiber Mixed Antifouling Coating Agent (셀룰로오스 나노섬유 혼합 방오코팅제가 도포된 콘크리트의 소수성능과 내구성능 평가)

  • Nak Sup Jang;Chi Hoon Nho;Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.1-8
    • /
    • 2023
  • Marine and hydraulic structures are subject to durability damage not only due to the penetration of sea water but also due to the attachment of marine organisms. Therefore, in this study, we tried to develop an antifouling coating agent with self-cleaning function for marine concrete. It was confirmed that the antifouling coating agent mixed with AKD, cellulose nanofibers and BADGE had sufficient antifouling performance at a well hydrophobicity of around 140° in contact angle and an inclination angle of 15°. In the abrasion resistance test of the surface, only a maximum loss of 0.015 g occurred. In the durability test, as a result of the chloride ion permeation test, almost no chloride ion permeation occurred in the variable where the coating agent was applied, and carbonation and freeze-thaw damage also rarely occurred, so it was analyzed that it was effective in securing durability of concrete.

Evaluation of Relationship between Strength and Resistance to Chloride in Concrete Containing Fly Ash with Ages (Fly Ash를 혼입한 콘크리트의 재령에 따른 강도와 염화물 저항능력간의 상관관계 평가)

  • Yoon, Yong-Sik;Park, Jae-Sung;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2017
  • Fly ash(FA) which is a byproduct in the coal combustion in thermal power plant contributes to pore structure densification due to pozzolanic reaction, and this leads to long-term strength development and excellent resistance to chloride penetration. In the work, compressive strength and chloride resistance in OPC(Ordinary Portland Cement) and FA-based concrete are evaluated, and the relationships are investigated considering ages. For the work, 3 different W/B (Water to Binder) ratios of 37%, 42%, and 47% are prepared, and 3 substitution ratio of fly ash(0%, 30%, and 50%) are considered as well. At the age of 28 days and 180 days, test results of compressive strength, diffusion coefficients based on Tang's method, and passed charges referred to ASTM C 1202 and KS F 2711 are obtained. With increasing replacement ratio of FA and decreasing W/B, the resistances to chlorides(diffusion coefficient and passed charge) are improved, and the results at the age of 180 days decrease to only 15% level at the age of 28 days due to pozzolanic reaction in FA 50 mixture, which shows that resistance to chloride is much dependent on age effect than strength development. After 180 days, more clear linear relationships are observed between strength and resistance to chloride.

Application of In-Situ Mixing Hydration Accelerator on Polymer Modified Concrete for Bonded Concrete Overlay (접착식 콘크리트 덧씌우기를 위한 초속경화 첨가재 현장 혼합 폴리머 개질 콘크리트의 적용성 연구)

  • Kim, Young Kyu;Hong, Seong Jae;Lee, Seung Woo
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.85-95
    • /
    • 2015
  • PURPOSES : Recently, bonded concrete overlay has been used as an alternative solution in concrete pavement rehabilitation since its material properties are similar to those of the existing concrete pavements. Deteriorated concrete pavements need rapid rehabilitation in order to prevent traffic jams on Korean expressways. Moreover, speedy and effective repair methods are required. Therefore, the use of bonded concrete overlay with ultra-rapid hardening cement has increased in an effort to reopen promptly the expressways in Korea. However, mobile mixer is required for ultra-rapid hardening cement concrete mixing in the construction site. The use of mobile mixer causes various disadvantages aforementioned such as limitation of the construction supply, open-air storage of mixing materials, increase in construction cost, and etc. In this study, therefore, hydration accelerator in-situ mixing on polymer modified concrete produced in concrete plant is attempted in order to avoid the disadvantages of existing bonded concrete overlay method using ultra-rapid hardening cement. METHODS : Bonded concrete overlay materials using ultra-rapid hardening cement should be meet all the requirements including structural characteristics, compatibility, durability for field application. Therefore, This study aimed to evaluate the application of hydration accelerator in-situ mixing on polymer modified concrete by evaluating structural characteristics, compatibility, durability and economic efficiency for bonded concrete overlay. RESULTS : Test results of structural characteristics showed that the compressive, flexural strength and bond strength were exceed 21MPa, 3.15MPa and 1.4MPa, respectively, which are the target strengths of four hours age for the purpose of prompt traffic reopening. In addition, tests of compatibility, such as drying shrinkage, coefficient of thermal expansion and modulus of elasticity, and durability (chloride ions penetration resistance, freezing-thawing resistance, scaling resistance, abrasion resistance and crack resistance), showed that the hydration accelerator in-situ mixing on polymer modified concrete were satisfied the required criteria. CONCLUSIONS : It was known that the hydration accelerator in-situ mixing on polymer modified concrete overlay method was applicable for bonded concrete overlay and was a good alternative method to substitute the existing bonded concrete overlay method since structural characteristics, compatibility, durability were satisfied the criteria and its economic efficiency was excellent compare to the existing bonded concrete overlay methods.

An Experimental Study on Permeable Water Proof Admixtures of Concrete (콘크리트 침투성 방수제의 실험적 연구)

  • 구민세;박언규
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.1
    • /
    • pp.138-144
    • /
    • 1996
  • At present, waterproof is absolutely needed to minimize the carbonation of bridge decks in Kor ea. In this research indoor experiments for penetrative waterproof admixture out of available methods are carried out to evaluate the resisting characteristics against natural arid artificial car bona ting conditions. The test results show that the optimal time of waterproof is 14 days after the concrete construc. tion but reconsideration is necessary for the application to high strength concrete because of the reduction in penetration of waterproof admixture. The results also show that the penetrat ive waterproof admixture has srrong resistance to the acid rain. However the waterproof capability of the admixture is not permanent especially under the natural exposure. Therefore the slab of a bridge should be paved with asphalt concrete. Other noticeable effects are the increase of heat and abrasion resistances from the use of the waterproof agents.

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

Assessment on Carbonation Resistance of Products for Protection and Repair of Concrete Structures (콘크리트 구조물 보수용 단면복구재 및 표면보호재의 중성화 저항성 평가)

  • Park, Sang-Soon;Ryu, Chung-Hyun;Park, Hun-Il;Shin, Hong-Chul;Ryu, Byung-Cheol;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.625-628
    • /
    • 2008
  • This study is performed to evaluate the carbonation resistance by measuring carbonation penetration depth and diffusion equivalent air layer thickness for 3 types of repair materials and 2 types of surface protection materials. Diffusion equivalent air layer thickness($S_D$) is thickness of a static air layer that possesses, under the same conditions, the same carbon dioxide permeability as the coating in accordance BS EN 1062-6. There is a significant advantage that continuous test is possible because it does not destroy the specimen. From experiment results, it is concluded that determination of carbon dioxide permeability is effective to evaluate for surface coating materials.

  • PDF

The Study of Antibiotic Resistance in Bacterial Biofilms (박테리아 생체막에 대한 항생제 내성 연구)

  • Kim Jin Wook;Joo Chi Un;Park Jin Yong;Lee Song Ae;Kim In Hae;Lee Jae Hwa
    • Environmental Mutagens and Carcinogens
    • /
    • v.25 no.4
    • /
    • pp.157-160
    • /
    • 2005
  • Antibiotic resistance of bacteria in the biofilm mode of growth contributes to the chronicity of infection and disease. The penetration of antibiotic, through biofilm developed in an itt vitro model system was investigated. Antibiotic resistant bacteria (E. coli) were obtained from Culture Collection of Antibiotic Resistant Microbes. Ca-alginate bead used as simulated biofilm and a cell entrapment test using compressed air were experiment for the improvement cell viability. Antibiotic susceptibilities though biofilms was measured by assaying the concentration of antibiotic that diffused through the biofilm to minimal inhibition concentration (MIC). Survival of immobilized cells were reduced as compared to free cells. In case of antibiotic susceptible E. coli reduced continuously, but antibiotic resistant E. coli kept up survival rate constantly. Survival was showed after exposed to the antibiotics that the more treated antibiotic resistant E. coli and low concentration of antibiotics) the more survived.

  • PDF

Experimental Study on the End Bearing Capacity of the Pile in a Group Pile (무리말뚝을 구성하는 개별말뚝의 선단지지력에 대한 실험연구)

  • Na, Yong Soo;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.6
    • /
    • pp.27-38
    • /
    • 2019
  • Bearing capacity of a pile in homogeneous soil is the sum of end bearing and skin resistance, and the skin resistance is more prominent in sandy soil. Bearing capacity of a pile in pile groups especially in sandy ground should be designed under the consideration of the influence by the adjacent piles. In this study, the end bearing capacity of a pile in pile groups was experimentally investigated. For this purpose, piles were installed in sandy ground in a circular test box, and end bearing - settlement behavior of the pile was measured while the pile was loaded. As the results, end bearing - settlement relation curves of the piles showed a distinct limit value. Limit value of the end bearing was little affected by skin friction and pile diameter, and it became a constant value as pile penetrates deeper. End bearing was not affected by the adjacent piles in a group of piles, when their clearance was larger than the pile diameter.

Studies on the Durable Characteristics of Self-Healing Concrete with High Water-Tightness for Artificial Ground (인공지반용 고수밀 기반 자기치유성 콘크리트의 내구특성에 관한 연구)

  • Song, Tae-Hyeob;Park, Ji-Sun;Kim, Byung-Yun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.199-206
    • /
    • 2019
  • Experimental study on the durability characteristics to examine the feasibility of concrete with high water-tightness and self-healing performance to minimize maintenance of concrete for artificial ground is as follows. 1) When blending agent, swelling agents, and curing accelerator were added on the ternary system cement with blast-furnace slag fine particles and fly ash to give a self-healing property, higher blending strengths by 82% at design standard strength of 24MPa and by 74% at design strength of 30MPa, respectively could be obtained. 2) The permeability test for the specimens having high water-tightness and no shrinkage showed that the permeability was reduced at maximum of 98%. However, the permeability was decreased as the design strength was increased, showing the reduction rate of 87% at the design strength of 50MPa. 3) The depth of carbonation of blast-furnace slag and fly ash was increased in all the specimens compared with those of OPC only. However, as the material age was increased, carbonation penetration depth was decreased compared with the reference blend. 4) Compared with the reference blending using only OPC, the freeze-thaw resistance was higher in the case of blending with 40% of blast-furnace slag and 10% of fly ash at the design standard strength of 50MPa. In addition, the freeze-thaw resistance in general was superior in the design standard strength of 50MPa with the lower water-binder ratio (W/B) as compared with the design standard strength of 24MPa and 30MPa with the high water-binder ratios.

Experimental study of graphene oxide on wollastonite induced cement mortar

  • Sairam, V.;Shanmugapriya, T.;Jain, Chetan;Agrahari, Himanshu Kumar;Malpani, Tanmay
    • Advances in concrete construction
    • /
    • v.12 no.6
    • /
    • pp.479-490
    • /
    • 2021
  • Present research is mainly focused on, microstructural and durability analysis of Graphene Oxide (GO) in Wollastonite (WO) induced cement mortar with silica fume. The study was conducted by evaluating the mechanical properties (compressive and flexural strength), durability properties (water absorption, sorptivity and sulphate resistance) and microstructural analysis by SEM. Cement mortar mix prepared by replacing 10% ordinary portland cement with SF was considered as the control mix. Wollastonite replacement level varied from 0 to 20% by weight of cement. The optimum replacement of wollastonite was found to be 15% and this was followed by four sets of mortar specimens with varying substitution levels of cementitious material with GO at dosage rates of 0.1%, 0.2%, 0.3% and 0.4% by weight. The results indicated that the addition of up to 15%WO and 0.3% GO improves the hydration process and increase the compressive strength and flexural strength of the mortar due to the pore volume reduction, thereby strengthening the mortar mix. The resistance to water penetration and sulphate attack of mortar mixes were generally improved with the dosage of GO in presence of 15% Wollastonite and 10% silica fume content in the mortar mix. Furthermore, FE-SEM test results showed that the WO influences the lattice framework of the cement hydration products increasing the bonding between silica fume particles and cement. The optimum mix containing 0.3% GO with 15% WO replacement exhibited extensive C-S-H formation along with a uniform densified structure indicating that calcium meta-silicate has filled the pores.