• Title/Summary/Keyword: penetrating

Search Result 999, Processing Time 0.024 seconds

Characteristics of the Illuminance Distributions by Artificial Lighting in Different Shading Systems (쉐이딩 시스템에 따른 인공조명에 의한 조도분포 특성에 관한 연구)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • Daylight responsive dimming system, which is one of the method for utilizing available daylight. continuously adjusts lighting output with an algorithm of the correlation of photosensor signal and workplane illuminance levels. This system must be related with shading systems which are to control penetrating daylight. The purpose of this research is to analyze illuminance distributions by artificial lighting in different shading systems. Lighting power is changed by 5 levels in nighttime for comparing correlation between illuminance and lighting power in different shading systems.

  • PDF

Deep Learning in Genomic and Medical Image Data Analysis: Challenges and Approaches

  • Yu, Ning;Yu, Zeng;Gu, Feng;Li, Tianrui;Tian, Xinmin;Pan, Yi
    • Journal of Information Processing Systems
    • /
    • v.13 no.2
    • /
    • pp.204-214
    • /
    • 2017
  • Artificial intelligence, especially deep learning technology, is penetrating the majority of research areas, including the field of bioinformatics. However, deep learning has some limitations, such as the complexity of parameter tuning, architecture design, and so forth. In this study, we analyze these issues and challenges in regards to its applications in bioinformatics, particularly genomic analysis and medical image analytics, and give the corresponding approaches and solutions. Although these solutions are mostly rule of thumb, they can effectively handle the issues connected to training learning machines. As such, we explore the tendency of deep learning technology by examining several directions, such as automation, scalability, individuality, mobility, integration, and intelligence warehousing.

Landmine Recognition System using principal component analysis (주성분 분석법을 이용한 지뢰인식 시스템)

  • Yi, Doe-Heon;Shin, Young-Suk
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06c
    • /
    • pp.427-431
    • /
    • 2007
  • 차세대 지뢰탐지 기술로는 NQR(Nuclear Quadrupole Resonance, 핵4중극자공명), GPR(Ground Penetrating Radar, 지상 침투 레이더)등 이 연구 및 개발 중 이다. 현재 우리나라에서도 이중 GPR을 차세대 지뢰탐지 기술로 연구중에 있다. 그렇지만 지금까지 개발된 GPR 기술을 적용한 지뢰탐지기는 얻어진 2차원 영상에 대해서 육안에 의한 식별만이 가능하여 지뢰 식별이 장시간 소요된다는 단점을 가지고 있다. 이에 본 논문에서는 그러한 문제를 해결하기 위해 주성분 분석법을 적용하여 해결하고, 제안된 시스템이 가능한지 확인하기 위해 유사한 실험 환경을 구성하고, 얻어진 영상을 학습시켜 실제로 얻어진 영상에 대한 분류가 가능한지를 확인하였다.

  • PDF

Inspection for Internal Flaw and Thickness of Concrete Tunnel Lining Using Impact Echo Test (충격반향시험에 의한 콘크리트 터널 라이닝 내부결함 및 두께 조사)

  • 김영근;이용호;정한중
    • Tunnel and Underground Space
    • /
    • v.7 no.3
    • /
    • pp.230-237
    • /
    • 1997
  • As concrete structure is getting old and decrepit, its inspection and diagnosis is getting important. Therefore, it is necessary to estimate the soundness of structure using non-destructive tests for effective repairs and maintenances. But, applications of non-destructive tests in tunnel have been used restrictively, due to accessibility only from one side in tunnel lining and presence of tunnel installations. Recently, the various non-destructive techniques have been studied. Especially, ground penetrating radar(GPR) and impact echo (IE) methods have been researched for tunnel inspection. In this study, the applicability of impact echo test in tunnel lining inspection has been investigated. This paper described the tunnel inspection for lining thickness and internal flaw using impact echo tests. Model tests were carried out using impact echo test systems on two concrete models, Model I is measuring for lining thickness, Model II is detecting for internal flaw. Also, the test were applied for lining inspections in a tunnel constructed by NATM. From the results of impact echo tests, we have concluded that impact echo test is a very useful and effective technique for inspecting the concrete tunnel linings.

  • PDF

Consumer Attitude Toward Purchasing US Brand Jeans (미국산 청바지 구매에 관한 소비자 태도 분석)

  • Kim-Jai-Ok
    • Journal of the Korean Society of Costume
    • /
    • v.28
    • /
    • pp.225-237
    • /
    • 1996
  • The product evaluation and purchasing behavior of US brand jeans have been studied. The intrinsic and extrinsic cues are usually adopted to interpret the purchasing decison making processes. Among extrinsic cues price and brand name have been studied exten-sively but country-of-origin has not been examined in Korea. With the liberalization of retail industry foreign brands are aggressively penetrating in Korean pparel market. Since the penetration of imported apparel has increased tremendously lately the consumer attitude toward foreign produced clothing has great importance. The findings of the study were 1) Price was the most important among extrinsic cues ex-cept quality. Brand name was more important than store and country-of-origin. 2) The country image had significant influence to the preference as apparel production country. 3) The evaluation and willingness to buy of the jeans were greatly influenced by the be-havioral charcteristics of consumer variables. 4) The model to predict the willingness to buy of the jeans has been developed.

  • PDF

A Study on the fast-rising switching surges charateristics in the 154KV transformers (154KV 변압기의 계통개폐 급준파 전압특성 연구)

  • Cho, Y.O.;Kim, I.S.;Kim, J.Y.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.907-910
    • /
    • 1992
  • This paper deals with the mesurement and the analysis by means of EMTP simulation for the fast-rising switching surges. The fast-rising surges having up to 180ns of front time and 3.42 p.u of peak value were measured at the 154KV substations. The fast-rising surges are expected to cause electric breakdown because the penetrating surges to the transformers result in the higher stress in the winding end than the average stress along the winding.

  • PDF

A study on the spray and flame by optically accessible D.I. diesel engine : analysis by Schlieren method and diffused background illumination method (가시용 직분식 디젤기관의 분무와 화염에 관한 연구)

  • 안수길;이덕보;라진홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.9-23
    • /
    • 1995
  • To analyze the spray and flame in D.I. diesel engine, the visualizing methods by schlieren photograph and diffused background illumination photograph with high speed camera are applied to optically accessible D.I.diesel engine. Wcaporating spray, spray droplets and brightness flame are taken with high speed camera by visuallizing method in accordance with various suction air temperature and injection time. The spray and flame image on the film was analyzed by image analyzer. The optically accessible D.I. diesel engine had the similar pressure characteristic to the real D.I. diesel engine. Experimental results showed that shadow areas of the evaporating spray were extended at higher suction air temperature, spray droplets had a max. Penetration length and their penetrating patterns were dependent on the surrounding gas temperature, and flame size after ignition was largely governed by the evaporated fuel quantity at ignition point and by the surrounding gas condition due to piston motion.

  • PDF

Delayed Subclavian Vein Stenosis without Thrombosis Following Clavicle Fracture

  • Kim, Do Wan;Jeong, In Seok;Na, Kook Joo
    • Journal of Trauma and Injury
    • /
    • v.32 no.4
    • /
    • pp.243-247
    • /
    • 2019
  • Subclavian vein injuries occasionally occur as a sequela of penetrating trauma or vascular access, but have rarely been reported to occur after clavicle fracture. The subclavian vessels are mainly enclosed by the subclavius muscle, the first rib, and the costocoracoid ligament. Therefore, in such cases, subclavian vein injury is rare because of the strcutures surrounding the subclavian vessels. Nevertheless, subclavian vein injuries occasionally show thrombotic manifestations, and thrombosis of the upper limbs constitutes 1-4% of cases of total deep vein thrombosis. Furthermore, to the best of the authors' knowledge, although vessel injuries have been reported after clavicle or rib fractures and nerve injuries to regions such as the brachial plexus, no case involving delayed presentation of isolated subclavian vein stenosis after clavicle fracture due to blunt trauma has yet been reported.

Papillary Muscle Rupture of The Left Ventricle - 3 Cases - (좌심실 유두근 파열;3례 보고)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.9
    • /
    • pp.936-942
    • /
    • 1992
  • There are three types of papillary muscle of the left ventricle[finger, tethered and mixed type] according to the morphology of the attachment to the ventricular wall. Especially finger type of the papillary muscle is more vulnerable to the injury than tethered or mixed type, because their blood supply is dependent upon the central artery whose diameter is less than 1mm and the papillary muscle itself is the end organ of the heart anatomically. There are several causes of papillary muscle rupture but few cases have been reported. Recently we have experienced 3 cases of papillary muscle rupture of the left ventricle with successful mitral valve replacement and the causes are postmyocardial infarction, percutaneous mitral valvulotomy and non-penetrating chest trauma. The common finding is the morphology of papillary muscle, that is the finger type and their rupture type is the complete type.

  • PDF

False aneurysm of right common carotid artery due to gun shot wound: report of a case (총창으로 인한 우측 총경동맥의 가성 동맥류 치험 1)

  • 남구현
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.488-491
    • /
    • 1984
  • Vascular injuries from gun shot wound is rare in these days, in Korea. A Case of false aneurysm of the right common carotid artery due to penetrating injury to the neck by carbine. The confirmatory diagnosis was made by right carotid angiogram which revealed bean-sized aneurysmal sac at the mid-portion of the right common carotid artery. Despite of no symptoms, emergency false aneurysmectomy and reconstruction with on-lay vein patch graft using left greater saphenous vein for threat of rupture and embolization from mural thrombi. During repair of common carotid artery, cerebral circulation was maintained with internal shunt. The postoperative course was uneventful except limit of motion of right upper extremity due to initial injury.

  • PDF