• Title/Summary/Keyword: pedal

Search Result 211, Processing Time 0.03 seconds

MoS2 Thickness-Modulated MoS2/p-Si Photodetector (MoS2 두께 변화에 따른 MoS2/p-Si 광센서 특성 연구)

  • Kim, Hong-Sik;Kim, Joondong
    • Current Photovoltaic Research
    • /
    • v.5 no.4
    • /
    • pp.145-149
    • /
    • 2017
  • Transition metal dichalcogenides (TMDs) have attracted much attention because of their excellent optical and electrical properties, which are the applications of next generation photoelectric devices. In this study, $MoS_2$, which is a representative material of TMDs, was formed by magnetic sputtering method and surface changes and optical characteristics were changed with thickness variation. In addition, by implementing the photodetector of $MoS_2/p-Si$ structure, it was confirmed that the change of the electrical properties rather than the change of the optical properties according to the thickness change of $MoS_2$ affects the photoresponse ratio of the photodetector. This result can be used to fabricate effective photoelectric devices using $MoS_2$.

Hybrid Transparent Conductor by using Solution-Processed AgNWs for High-Performing Si Photodetectors

  • Kim, Hong-Sik;Kim, Joondong
    • Current Photovoltaic Research
    • /
    • v.3 no.4
    • /
    • pp.116-120
    • /
    • 2015
  • A hybrid transparent conducting layer was applied for Si photodetector. To realize the hybrid transparent conducting layer, a 200 nm-thick ITO layer was deposited onto a Si substrate, following by a solution-processed AgNWs-coating on the ITO. The hybrid transparent conducting layer showed an excellent low electric resistance of $15.9{\Box}/{\Omega}$ with a high optical transparency of 86.89%. Due to these optical and electrical benefits, the hybrid transparent conductor-embedding Si diode provides an extremely high rectifying ratio of 3386. Under light-illumination, the hybrid transparent conductor device provides extremely high photoresponses for broad wavelengths. This implies that a functional design for hybrid transparent conductor is crucial for photoelectric devices and applications.

Driving Performance Evaluation Using Bio-signals from the Prefrontal Lobe in the Driving Simulator

  • Kim, Young-Hyun;Kim, Yong-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.319-325
    • /
    • 2012
  • Objective: The aim of this study was to develop the assistive device for accelerator and brake pedals using bio-signals from the prefrontal lobe in the driving simulator and evaluate its performance. Background: There is lack of assistive devices for the driving in peoples with disabilities in Korea. However, if bio-signals and/or brain waves are used at driving a car, the people with serious physical limitations can improve their community mobility. Method: 15 subjects with driver's license participated in this study for experiment of driving performance evaluation in the simulator. Each subject drove the simulator the same course 10 times in three separated groups which use different interface controllers to accelerate and brake: (1) conventional pedal group, (2) joystick group and (3) bio-signal group(horizontal quick glance of the eyes and clench teeth). All experiments were recorded and the driving performances were evaluated by three inspectors. Results: Average score of bio-signal group for the driving in the simulator was increased 3% compared with the pedal group and was increased 9% compared with the joystick group(p<0.01). The subjects using bio-signals was decreased 44% in number of deduction compared with others because the device had the built-in modified cruise control. Conclusion: The assistive device for accelerator and brake pedals using bio-signals showed significantly better performance than using general pedal and a joystick interface(p<0.01). Application: This study can be used to design adaptive vehicle for driving in people with disabilities.

Analysis of Muscle Activities and Driving Performance for Manipulating Brake and Accelerator Pedal by using Left and Right Hand Control Devices (장애인용 핸드컨트롤을 이용한 가속 및 제동 페달을 동작할 때의 상지 근육 EMG 분석 및 운전 성능 평가)

  • Song, Jeongheon;Kim, Yongchul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • The purpose of this study was to investigate the EMG characteristics of driver's upper extremity and driving performance for manipulating brake and accelerator pedal by using left and right hand control devices during simulated driving. The people with disabilities in the lower limb have problems in operation of the motor vehicle because of functional loss for manipulating brake and accelerator pedal. Therefore, if hand control device is used for adaptive driving controls in people with lower limb impairments, the disabled people can improve their quality of life by driving a motor vehicle. Six subjects were participated in this study to evaluate driving performance and muscle activities for operating brake and accelerator pedal by using two different hand controls (steering column mounted hand control and floor mounted hand control) in driving simulator. We measured EMG activities of six muscles (posterior deltoid, middle deltoid, triceps, biceps, flexor carpi radialis, and extensor carpi radialis) during pushing and pulling movement with different hand controls for acceleration and braking. STISim Drive 3 software was used for the performance test of different hand control devices in straight lane course for time to reach target speed and brake reaction time. While pulling the hand control lever toward the driver, normalized EMG activities of middle deltoid, triceps and flexor carpi radialis in subjects with disabilities were significantly increased (p < 0.05) compared to the normal subjects. It was also found that muscle responses of posterior deltoid were significantly increased (p < 0.05) when using the right hand control than left hand control. While pushing the hand control lever forward away from the driver, normalized EMG activities of posterior deltoid, middle deltoid and extensor carpi radialis in subjects with disability were significantly increased (p < 0.05) compared to the normal subjects. It was shown that muscle responses of middle deltoid, biceps and extensor carpi radialis were significantly increased when using the right hand control than left hand control. Brake reaction time and time to reach target speed in subjects with disability was increased by 12% and 11.3% on average compared to normal subjects. The subjects with physical disabilities showed a tendency to relatively slow acceleration at the straight lane course.

DEVELOPMENT OF INVERTER AND POWER CAPACITORS FOR MILD HYBRID VEHICLE (MHV) - TOYOTA "CROWN"

  • Shida, Y.;Kanda, M.;Ohta, K.;Furuta, S.;Ishii, J.
    • International Journal of Automotive Technology
    • /
    • v.4 no.1
    • /
    • pp.41-45
    • /
    • 2003
  • The 42V Mild Hybrid System has been released into market by Toyota for the first time in the world in 2001. The set-up employs an inverter unit to control the motor/generator (MG) electronically. The driving system called such as Toyota Mild Hybrid System (TMHS) has additional new functions to conventional internal combustion engines. When stopping vehicle, the engine stops promptly. When starting vehicle, by releasing the brake pedal MG starts the vehicle at the same time (EV-driving mode). When stepping on the accelerator pedal, or after a given period of time the engine firing occurs and the engine-driving mode starts. When running by motor, the power is supplied to the motor from 36V battery through the inverter. High outputs and instant responses are required for Inverter. At the same time, the compact volume is required to fit into the limited space of the engine room. The compact size and high output are also required to Power Capacitor used for this inverter. The power capacitors has been newly developed, shaped in "flat" type, suitably for the inverter. The points of developments on inverter and power capacitor are described in this paper.his paper.

A Study on Manufacture and Control of a Self Manufacturing Hybrid Electric Vehicle (자작형 하이브리드카의 제작 및 제어에 관한 연구)

  • Kim, Hack-Sun;Jeong, Chan-Se;Yang, Soon-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • In this paper, Hybrid Electric Vehicle is directly designed and manufactured for base study of HEV's system and Green Car. Foundation design consists of power train design and the frame design. The power train concept includes motor, engine, generator and battery. And the concept of the frame is the single-seat of this self-made HEV. A frame installed in hybrid system contains suspension, steering wheel, seat, accelerating pedal, brake pedal, clutch handle and various chassis parts with bearings. Electromagnetic clutch is equipped to transmit engine power to drive axle. The control algorism make using LabVIEW to control of an engine and a motor depending on drive condition. A parallel type hybrid system is manufactured to control operation of a motor and an engine depending on vehicle speed.

Usability of Cockpit Design and Musculoskeletal Discomfort in Korean Air Force Fighter Pilots (한국 공군 주력 전투기 조종실의 사용성과 조종사의 근 골격계 불편도에 대한 연구)

  • Byun, Seong-Nam;Lee, Dong-Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.1
    • /
    • pp.100-110
    • /
    • 1999
  • The objectives of this study are twofold: (1) to evaluate the cockpit of three Korean air force fighters such as F-4, F-5, and F-16 in an ergonomic perspective and (2) to measure the musculoskeletal discomfort of the fighter pilots. For the study, 369 air force pilots from 7 squadrons were surveyed. The study shows that the cockpit design of F-16 is superior to the others. However, F-4 is the worst among them. Statistical analyses reveal that the seat in the cockpit raised the most complaints, regardless of types of fighter planes. The main problems with the seat included inappropriate designs of the backrest angle, seat cushioning, and parachute harness. Also frequently cited are various control switches, control stick, rudder pedal, and the throttle. That these items lack human integration is found in remote positions and improper dimensions. The implications of these findings are discussed. The self-reported musculoskeletal complaints show that the main discomfort is on the back and neck. Also, the buttocks, shoulders, and the legs/knees are common sites of discomfort. A stepwise regression analysis shows that the back discomfort, is mainly caused by the use of the seat, rudder pedal, control stick, and switches. A Spearman rank correlation coefficient test also reveals that job dissatisfaction of the pilots is related to the complaints with the cockpit and musculoskeletal discomfort. These findings suggest that more comprehensive studies for cockpit design in the aspects of functional anthropometry of Korean pilots are needed to reduce the musculoskeletal discomfort.

  • PDF

Reliability Evaluation of EDR Data Using PC-Crash & Vbox (Vbox와 PC-Crash를 활용한 EDR 기록정보의 신뢰성 평가)

  • Park, Jongchan;Kim, Jonghyuk;Oh, Wontaek;Choi, Jihun;Park, Jongjin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.317-325
    • /
    • 2017
  • The EDR(Event Data Recorder) is a part of the ACU(Airbag Control Unit) functions mounted on a vehicle. EDR data have pre-crash data and post-crash data. Pre-crash data are recorded within 5 sec from time zero(AE) with 0.5 sec resolution, and reveal vehicle speed, engine rotation speed, throttle opening, brake pedal operation, acceleration pedal position and steering angle, etc. Using this EDR data, the investigation of a traffic accident can become more objective and scientific. Crash tests of three vehicles equipped with EDR function had been performed successfully. Evaluation of EDR data reliability had also been performed using Vbox and PC-Crash's sequence table function. Based on the results, we could confirm EDR data's reliability and availability for Traffic Accident Analysis by the series of this process.

Analysis of Respiratory Gas by Training on Healthcare Indoor Bicycle (헬스케어용 실내 자전거 운동에 의한 호흡가스 분석)

  • Hong, Chul-Un;Kang, Hyung-Sub;Kim, Gi-Beum
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.147-152
    • /
    • 2009
  • This study was conducted to observe the change of limbs stroke and respiration gas parameters in our new bicycle fitness system. We hypothesized that the variable force of left and right limbs might be effective for sensing stimulation in modified new unequal pedal bicycle system. It has been developed, which can provide visual information and different length of pedal with left and right limbs. Experimental results showed different activities between the left and right limbs where the activity of the left limb increased than that of right limb. Especially, the soleous muscle activity increased both in control and experimental groups by this training method. But oxygen and carbon dioxide partial pressures in respiratory gas increased during training method. These results suggest that acidosis of blood was led by this process. Consequently, this bicycle training is concluded that aerobic training could affect different limb activities. Finally, we expect that our new bicycle system will be effective for healthcare with proper balance between the left and right limbs.