• 제목/요약/키워드: peak current

검색결과 1,752건 처리시간 0.028초

진공증착법에 의해 제조된 PVDF 박막의 전기전도현상과 열자격전류에 관한 연구 (A Study on the electrical condution phenomena and TSC of PVDF thin films fabricated by PVD method)

  • 이선우;박수홍;이덕출
    • 한국진공학회지
    • /
    • 제8권3A호
    • /
    • pp.187-193
    • /
    • 1999
  • In this study, PVDF thin films which show the excellent piezoelectricity and pyroelectricity, are prepared by PVD (physical vapor deposition) method, and thir electrical conduction phenomena for analyses of the electrical conduction mechanism and TSC (Thermally Stimulated Current) for identification of the behavior of conductive carriers are investigated. As a result of FT-IR(Fourier Transform Infrared Spectroscopy) spectra, the crystalline phase transforms $\alpha$ type into $\beta$ type with increasing electric field. From XRD (X-Ray diffraction) analyses patterns, the degree of crystallinity increases from 49.8% to 67%, as the substrate temperature increases from $30^{\circ}C$ to $80^{\circ}C$. As a result of electrical conduction phenomena, the electrical conduction mechanism of PVDF thin films is identified as ionic conduction mechanism. From TSC analyses, there are three peaks as P1, P2, P3 with increasing temperature, and with increasing substrate temperature, the peak temperature of TSC increases and the peak intensity of TSC decreases.

  • PDF

ON THE SONO-VOLTAMMETRY CURVES OF POLYCRYSTALLINE PLATINUM ELECTRODE IN SULFURIC ACID SOLUTION

  • Chiba, Atsushi;Kobayashi, Katsuyoshi;Yamashita, Tsugito
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.366-371
    • /
    • 1999
  • The volumetric curve was characterized by current functions of large amplitude and formation peak potential of adsorption oxygen (O(a)) was disappeared with sonication. The reduction peak potential of O(a) shifted about 0.05 V to noble direction in saturated $N_2$ and air systems with addition of $Cl^{-1}$ ion and sonication. The formation and ionization potentials of adsorption hydrogen (H(a)) had not been confirmed, and were not changed with sonication.

  • PDF

Electrochemical and Spectrofluorometric Behaviors of Eu(III) Complexes in Aqueous Solution

  • Chae Won-Seok;Kim Kang-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권12호
    • /
    • pp.1050-1054
    • /
    • 1994
  • Eu(Ⅲ) exhibits one electron-transfer reduction at E$_{1/2}$ =-0.617 V vs. Ag/AgCl and the hypersensitive peak at 618 nm corresponding to $^5D_0$ ${\leftrightarro}$ $^7F_2$ transition in 0.10 M LiClO$_4$ aqueous solutions. Upon the addition of carboxylate or sulfonate anions to the Eu(Ⅲ) aqueous solutions, the reduction potential shifts negatively and the reduction current decreases because of the complex formation between Eu(Ⅲ) ions and the anions. However, for the case of carboxylate anion (acetate or propionate) the shift of reduction peak potential and the emission intensity at 618 nm are greater. The results are interpreted in terms of the differences in the formation constants and the hypersensitivity.

Impacts of temporal dependent errors in radar rainfall estimate for rainfall-runoff simulation

  • Ko, Dasang;Park, Taewoong;Lee, Taesam
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.180-180
    • /
    • 2015
  • Weather radar has been widely used in measuring precipitation and discharge and predicting flood risks. The radar rainfall estimate has one of the essential problems in terms of uncertainty and accuracy. Previous study analyzed radar errors to reduce its uncertainty or to improve its accuracy. Furthermore, a recent analyzed the effect of radar error on rainfall-runoff using spatial error model (SEM). SEM appropriately reproduced radar error including spatial correlation. Since the SEM does not take the time dependence into account, its time variability was not properly investigated. Therefore, in the current study, we extend the SEM including time dependence as well as spatial dependence, named after Spatial-Temporal Error Model (STEM). Radar rainfall events generated with STEM were tested so that the peak runoff from the response of a basin could be investigated according to dependent error. The Nam River basin, South Korea, was employed to illustrate the effects of STEM on runoff peak flow.

  • PDF

Predictive Control Algorithms for Adaptive Optical Wavefront Correction in Free-space Optical Communication

  • Ke, Xizheng;Yang, Shangjun;Wu, Yifan
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.641-651
    • /
    • 2021
  • To handle the servo delay in a real-time adaptive optics system, a linear subspace system identification algorithm was employed to model the system, and the accuracy of the system identification was verified by numerical calculation. Experimental verification was conducted in a real test bed system. Through analysis and comparison of the experimental results, the convergence can be achieved only 200 times with prediction and 300 times without prediction. After the wavefront peak-to-valley value converges, its mean values are 0.27, 4.27, and 10.14 ㎛ when the communication distances are 1.2, 4.5, and 10.2 km, respectively. The prediction algorithm can effectively improve the convergence speed of the peak-to-valley value and improve the free-space optical communication performance.

Spin injection and transport properties of Co/Au/Y$Ba_2$$Cu_3$$O_y$ tunnel junctions

  • Lee, Kiejin;Kim, Sunmi;Ishibashi, Takauki;Cha, Deokjoon
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.70-73
    • /
    • 2001
  • We report the spin injection and transport properties of three terminal devices of Co/Au/$YBa_2$$Cu_3$$O_{y}$(F/N/S) tunnel junctions by injection of spin-polarized quaiparticles using a cobalt ferromagnetic injector. The observed current gain depends on the thickness of Au interlayer and is directly related to the nonequilibrium magnetization due to spin relaxation effects. The tunnel characteristic of a F/N/S tunnel junctions exhibited a zero bias conductance peak (ZBCP). The suppression of the ZBCP was observed due to the suppression of Andreev reflection at the interface, which is due to the spin scattering processes at the interface between a ferromagnetic and a d-wave superconductor.r.

  • PDF

전기영동 디스플레이에서 전자 잉크의 전류 특성 및 평가 (Current Properties and Evaluation of Electronic Ink in Electrophoretic Display)

  • 안형진;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.31-36
    • /
    • 2020
  • An investigation was conducted to determine whether the ratio of the fluid to the charged particles affects the panel reflexibility rate and the drifting current flowing in the panel, in electrophoretic-based electronic paper. In this regard, three panels were produced in this study with the ratio of the charged particles to the fluid set as 1:5, 1:1, and 5:1. Each sample was driven using an identical input pulse, for which the current flowing in the panel and the output voltage of the photodiode were measured for the panel reflexibility rate. Consequently, the drifting current initially exhibited a peak value and a saturated value at a later point. This value was proportional to the ratio of the charged particles, and it was similar to this ratio when it is higher than 1:1. The output voltage of the photodiode due to the panel reflexibility rate was proportional to the ratio of the charged particles. However, the response speed decreased if the ratio was higher than 1:1. It is expected that the results of this study will contribute to the analysis of the charging of charged particles in electrophoretic-based electronic paper, and the selection of an appropriate concentration.

Experimental and Analytical Study on the Bus Duct System for the Prediction of Temperature Variations Due To the Fluctuation of Load

  • Thirumurugaveerakumar, S.;Sakthivel, M.;Valarmathi, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2036-2041
    • /
    • 2014
  • In this paper, a thermal model is developed for the bus bar system to predict the temperature variation during the transient time period and to calculate both the steady-state and transient electrical current carrying capacity (ampacity) of bus bar. The bus bar system installed in the power house of Kumaraguru College of Technology, Coimbatore has been considered. Temperature variation predicted in the modelling is validated by observing the current and steady state temperatures in different feeders of the bus bar. Magnetic field of the extreme phases R and B induces more current in the middle phase Y. Hence, the steady state temperature in the phase Y is greater than other two phases. The transient capabilities of the bus bar are illustrated by calculating the variations in the bus bar temperature when it is subjected to a step change in current during the peak hours due to increase in hostel utilities and facilities (5.30 pm to 10.30 pm). The physical and geometrical properties of the bus bar and temperature variation in the bus bar are used to estimate the thermal time constants for common bus bar cross-sections. An analytical expression for the time constant of the bus bar is derived.

변전소내 정보기기에서 서지의 측정과 분석 (Measurement and Analysis of Surges on Information Devices Installed in a Power Substation)

  • 송재용;박대원;서황동;한주섭;길경석
    • 한국정보통신학회논문지
    • /
    • 제9권2호
    • /
    • pp.289-294
    • /
    • 2005
  • 본 논문은 변전소내 정보기기에 나타나는 서지전압 전류의 측정 결과에 대해 기술하였다. 서지전압 전류 관측을 위한 전력분석기는 전력용 변압기와 개폐기 주변의 신호선에 설치하였으며, 전력분석기의 시간분해능은 4 MS/s이다. 측정된 서지전압.전류의 크기는 각각 500~1,300v와 500~3,100k 이었으며, 측정기간 동안 평균 5~10회/일 이상의 서지가 기록되었다. 따라서 고전압 전력설비 주변에 설치되는 정보기기는 설치환경에 나타나는 서지의 크기를 고려하여 설계되어야 할 것이다.

염무-열 반복 열화에 따른 실리콘 고무의 표면열화특성변화 (The change of surface degradation properties of silicone rubber for salt fog)

  • 오태승;이청;박수길;류부형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.886-889
    • /
    • 2001
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity and chemical stability. But, the leakge current occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current is important to estimate the condition of the silicone rubber surface. In this paper, aging characteristics of silicone rubber used for outdoor insulation have been hydrophobicity of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, A1$_2$O$_3$$.$3H$_2$O) filler contents. The experimental results show that a higher peak leakage current and to raise a long time for tracking with increasing amount of ATH by the salt fog and heat recycle ageing.

  • PDF