• 제목/요약/키워드: patient moving

Search Result 210, Processing Time 0.022 seconds

A Non-contact Realtime Heart Rate Estimation Using IR-UWB Radar (IR-UWB 레이더를 이용한 비접촉 실시간 심박탐지)

  • Byun, Sang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.3
    • /
    • pp.123-131
    • /
    • 2019
  • In recent years, a non-contact respiration and heart rates monitoring via IR-UWB radar has been paid much attention to in various applications - patient monitoring, occupancy detection, survivor exploring in disaster area, etc. In this paper, we address a novel approach of real time heart rate estimation using IR-UWB radar. We apply sine fitting and peak detection method for estimating respiration rate and heart rate, respectively. We also deploy two techniques to mitigate the error caused by wrong estimation of respiration rate: a moving average filter and finding the frequency of the highest occurrence. Experimental results show that the algorithm can estimate heart rate in real time when respiration rate is presumed to be estimated accurately.

A Study on the Radio Transmission of Bio-Signal for Tele-Medicine (원격진료를 위한 생체신호의 무선전송에 대한 연구)

  • 김정년;곽준혁;최조천;조학현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.379-385
    • /
    • 2002
  • Tele-medicine and emergency medical system are necessary for moving from an accidental point or far distance to a hospital and emergency treatment or home treatment before a hospital. Emergency treatment is extremely important in the case of death before arriving a hospital and deformed of disabled by medical treatment delay. A necessary element for this medical system is the emergency communication system. This system is on preparing for an ability of furnishing patient status to a corresponding health service by monitoring the patient at an ambulance of the accident place. This is the transportation of basic biological information of a patient to a medical center by wireless communication system and the corresponding hospital of medical center examine the patient by monitoring, then they can send emergency medical order to the patient for emergency treatment. The TRS is most efficient way of emergency medical communication system, which is currently used with popularity. In this paper studied simultaneously a way of detecting and transporting bio-logical signals, and monitoring of transporting data with communication of voice in the accident place of ambulance.

Design of A Portable Device for Measuring Heart Rate Using Harmonic Signal and Adaptive Filter (하모닉 신호와 적응 필터를 이용한 휴대형 심박수 측정 장치 설계)

  • Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.723-728
    • /
    • 2010
  • This study proposed a design of a portable device for measuring heart rate using photoplethysmograph signal to minimize load of a nurse increased from insufficiency of an internal hospital nurse, and algorithm to measure reliable heart rate in PPG signals despite the existence of patient's motion artifacts. The proposed method for measuring heart rate is the method to minimize the motion interference by using the adaptive filter based on harmonic characteristic of PPG signal. To evaluate the performances of the a portable device implemented by the proposed method, we used several motion artifacts including finger and wrist movements; we then compared out results with the performance of the moving average filter. In this results, the proposed method showed a better performance than that of the moving average filter. Therefore, when nurses use the a portable device for measuring heart rate proposed in this study, it will enable to improve nurse work and to measure the reliable heart rate.

Evaluated Absorbed Dose According to Prescribed Dose and Therapeutic Technique in Radiation Therapy (방사선치료 시 처방선량과 치료기법에 따른 흡수선량 평가)

  • Lee, Deuk-hee;Park, Eun-tae;Kim, Jung-hoon;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.469-476
    • /
    • 2016
  • In this study, evaluated absorbed dose of moving target using PLD according to prescribed dose and therapeutic technique. First, result of MCNPX when target was deviated from exposure field was reduced dose in proportion to distance. According to prescribed dose, absorbed dose of 3D CRT was better than IMRT in low dose and IMRT was more better in high dose. Absorbed dose of 3D CRT was highest according to therapeutic technique. Therefore, 3D CRT was technique of irradiated highest dose to moving target. But, considered protective effect of normal tissue and patient condition that therapeutic technique was selected to maximized treatment efficiency.

A preparation and Strategy against Chemical and Biological Terrorism (화생방 테러의 양상과 예방대책)

  • Kim, Kyung-Hoe
    • Korean Security Journal
    • /
    • no.5
    • /
    • pp.19-40
    • /
    • 2002
  • For front, aspect of terror may have to prepare indeed even chemical terror or rocket and small size missile and radioactivity terror because is predicted to become various. Furthermore, when see motion of every countries about nuclear engineerses' bringing round and illicit sale of plutonium, our country may have to prepare in terrorism which is expected thus. So that can finish international event successfully because the United States of America supports great manpower and budget since New York's World Trade Center terror and when see that is considering terror prevention countermeasure, we operate temporarily bursting tube state complete charge team such as terror by each field specialist such as a concern interested including special CBR complete charge moving team among 2002 World Cups soccer game period ahead of international event, must consider safety countermeasure. Specially, biology weapon of chemical weapon and cholera etc. 13 kinds of 5000ton that North Korea plans CBR terror society confusion that North Korea that to terror support nation as well as nuclear weapons development suspicion is defending South Korea communization strategy as real condition that is amplified as well as is saving production brand gets imprinted uses CBR terror at normal times, when see that is planing powerlessness communization unity using CBR weapon at time of war, must operate until bias 2002 World Cups international event finishes cooperation safety countermeasure utensil safely under closer talk between the South Korea ${\cdot}$ Japan ${\cdot}$ North Korea. As for us which must serve 2002 World Cup successfully to accomplish perfectly preparedness of CBR terror firstly, all inhabitants knows well CBR protection trick, and secondly, CBR existing formation that solidify realignment CBR complete charge moving team which of course is consisted of CBR specialist compose and keeping immediate going out attitude operating, by third, that expand CBR individual protection equipment and CBR evacuation equipment and establish individual and group protection attitude naturally, supplement as there is main room that actualize CBR pollution patient's slogan countermeasure by fourth, and develop standard model for CBR terror provision by fifthBecause constructing infra of CBR safety establishing CBR preparedness that utilize it, must minimize damage and contribute inhabitants' life and property protection.

  • PDF

Computer Analysis of Kinematic Parameters of the Intact Heart Using X-ray Image Sequence (X-ray 영상을 이용한 심장운동해석에 관한 연구)

  • Min, Byeong-Gu;Kim, Seong-Wan;Kim, Hui-Chan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.4
    • /
    • pp.101-112
    • /
    • 1985
  • It is important to extract the mechanical informations from the image sequences of the moving object. We have studied the computer algorithms for analysis of the moving heart using X-ray image sequence. A new mathematical method was developed to estimate the local epicardial deformation, wall thickness, and the regional circumferential and longitudinal wall stress using biplane coronary cineangiograms. In this method, the motion images of the coronary artery bifurca-tion points were used as natural landmarks for the kinematic analysis of the ventricular deformation. In four dogs and a normal patient's coronary cineangiograms, the estimation results show the validity of the present analysis, compared with the experimental results based upon the implanted markers. Thus, the present method provides a new method of evaluating the regional wall deformation and wall stress together with the blood vessel conditions using the coronary cineangiography procedure.

  • PDF

Correction of Tooth-to-tooth Contact and Class IV Mesiodistocclusion by Orthodontic Tooth Movement in Three Dogs (세 마리 개에서 교정적 치아이동에 의한 치아-치아 접촉 및 IV급 근원심교합의 교정)

  • Kim, Se-Eun;Shim, Kyung-Mi;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Three Maltese dogs, 5 to 7 months old, were admitted to the Veterinary Medical Teaching Hospital, Chonnam National University with malocclusion including Class IV mesiodistocclusion. In the first case, the treatment was performed by moving the mandibular canine teeth caudally with orthodontic buttons and Masel chains. The second patient was treated for rostroverted mandibular canines using buttons and chains. When distal movement of the mandibular canine teeth was completed, a maxillary arch wire with finger springs was applied to push the incisor teeth forward. In the third case, the treatment began by moving the mandibular canine teeth caudally with buttons and chains. An arch wire with finger springs was applied at maxilla to move the maxillary incisor teeth labially. Additionally, the mandibular incisor teeth were moved lingually by an elastic band attached to the buttons cemented to mandibular canine teeth. As a result, all patients successfully regained a normal occlusion.

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Proposal of elevator calling intelligent IoT system using smartphone Bluetooth (스마트폰 블루투스를 이용한 승강기 호출 지능형 IoT 시스템 제안)

  • Si Yeon Kim;Sun-Kuk Noh
    • Smart Media Journal
    • /
    • v.13 no.1
    • /
    • pp.60-66
    • /
    • 2024
  • The Internet of Things, which began by connecting sensors through a network, is developing into an intelligent IoT by combining it with artificial intelligence technology. Elevators are essential for high-rise buildings in the city, and elevators move from floor to floor and perform the functions of transporting goods and moving users. It is necessary to provide safe and convenient services for elevator users in high-rise buildings or special environments (hospitals, etc.). In an environment where rapid patient transportation is important, such as large hospitals, there is a problem that hospital staff and the general public often use the elevator for patients. In particular, when moving patients where golden time is important, the waiting time to board the elevator is a major hindrance. In order to solve this problem, this study proposes an intelligent IoT system for elevator calling using smartphone Bluetooth. First, we experimented with the elevator calling IoT system using smartphone Bluetooth, and as a result of the experiment, it was confirmed that it can authenticate elevator users and reduce unnecessary waiting time for boarding. In addition, we propose an intelligent IoT system that connects with intelligent IoT.

Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam (고에너지 선형가속기에 의한 입체방사선수술의 선량특성)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • Three-dimensional dose calculations based on CT images are fundamental to stereotactic radiosurgery for small intracranial tumor. In our stereotactic radiosurgery program, irradiations have been performed using the 6 MV photon beam of linear accelerator after stereotactic CT investigations of the target center through the beam's-eye view and the coordinates of BRW frame converted to that of radiosurgery. Also we can describe the tumor diameter and the shape in three dimensional configuration. Non-coplanar irradiation technique was developed that it consists of a combination of a moving field with a gantry angle of $140^{\circ}$, and a horizontal couch angle of $200^{\circ}C$ around the isocenter. In this radiosurgery technique, we provide the patient head setup in the base-ring holder and rotate around body axis. The total gantry moving range shows angle of 2520 degrees via two different types of gantry movement in a plane perpendicular to the axis of patient. The 3-D isodose curves overlapped to the tumor contours in screen and analytic dose profiles in calculation area were provided to calculate the thickness of $80\%$ of tumor center dose to $20\%$ of that. Furtheremore we provided the 3-D dose profiles in entire calculation plane. In this experiments, measured isodose curves in phantom irradiation have shown very similiar to that of computer generations.

  • PDF