복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

선질계수에 의한 피부입사선량 계산법 (Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor)

  • 김성철;김종일;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제10권2호
    • /
    • pp.258-267
    • /
    • 2010
  • 방사선피폭에 대한 관심이 높아지면서 X선 검사시에 환자에게 조사되는 피폭선량을 정확히 알고 있다는 것은 환자의 불안을 해소하고 또 방사선사나 의사가 피폭선량 경감의식을 향상시키는 데 중요하지만, 임상에서 측정기를 보유하고 있는 시설은 극소수에 불과하다. 본 연구에서는 bit system 및 NDD-M법의 특징을 살려서 우리나라에 사용되고 있는 진단용 X선장치의 출력선량을 직접 측정하여 도표화 하고, X선 출력선량을 아는 경우 또는 모르는 경우 모두에서 적절히 적용할 수 있게 두 가지 방법을 제시하여 실측선량과 비교 실험을 하였다. 그 결과 bit system 및 NDD-M법보다 정확도가 우수한 결과를 나타내어 임상에서 환자가 받는 선량을 더욱 쉽게 알 수 있게 됨으로 방사선관련 종사자들의 의료피폭에 대한 관심이 더욱 높아지고 의료선량감소에 한층 더 노력하는 계기가 될 것으로 사료된다.

디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가 (The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography)

  • 김미영;김화선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.293-298
    • /
    • 2012
  • 디지털 유방촬영술은 유방의 두께 및 유선조직의 밀도에 따라 노출조건이 자동으로 이루어지는 자동노출제어장치를 사용하고 있는데 이는 피폭선량을 증가시키는 원인이 되기도 한다. 이 연구에서는 디지털 유방확대촬영술에서 영상의 질을 유지하며 불필요한 방사선 피폭을 줄이기 위한 최적의 방사선량 촬영조건을 알아보았다. 자동노출방식을 사용할 경우 가장 좋은 영상화질을 얻을 수 있었으나 평균유선선량 역시 가장 높았다. 수동노출방식의 경우 자동노출방식의 55 % 정도의 mAs 값만으로도 기준 팬텀영상 점수와 신호대잡음비를 얻을 수 있으며 평균유선선량은 55 % 이하로 줄일 수 있었다. 위와 같은 결과를 참고로 하면 디지털 유방확대촬영 시 자동노출방식보다는 수동노출방식을 이용함으로써 불필요한 환자의 피폭선량을 줄일 수 있을 것이라 생각된다.

국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량 (Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea)

  • 최진우
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

Videodensitometry법을 이용한 X선사진의 흑화도와 대조도에 관한 연구 (THE VIDEODENSITOMETRIC ANALYSIS OF THE RADIOGRAPHIC DENSITY AND CONTRAST)

  • 유영선;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.293-303
    • /
    • 1992
  • Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with selfcuring acrylic resins attached with aluminum step wedge was used and readability of radiograms were compared with each other by videodensitometry among various combination sets of the exposure time, such as 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. At the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-constant radiographic density, the radiographic contrast was reduced with the increment kilovoltage. The radiographic contrast was increased in the lower kilovoltage with the longer exposure time and the higher kilovoltage with the shorter exposure time. 4. At the condition of short exposure time, better readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms. Since X-ray machine in the current dental clinics is fixed between the range of 60-70kVp and 10mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  • PDF

PET/CT 검사 환자의 피폭선량 경감을 위한 연구 (Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam)

  • 김봉수;표성재;조용귀;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.10-16
    • /
    • 2009
  • 목적 : 환자의 피폭선량 감소를 위해 PET/CT검사 시Pitch를 조절하여 환자의 피폭선량을 줄일 수 있는 방법에 대해 고려해 보고 Pitch 조정이 CT 영상과 PET의 SUV값에 영향을 주어 변화가 있는지를 살펴 보고자 한다. 방법 : Siemens사의 Biograph Positron Emission Tomography (PET) Scanner (CT 형식 : TRCT-240-130 (WCT-240-130)을 사용하였다. 환자의 피폭선량 평가로는 CT 조사선량 측정기인 PTW-DIADOS 11003/1383를 사용하여 선량을 측정하였고 Pitch 조정이 CT 영상에 미치는 영향을 알아보기 위해 AAPM Standard Phantom을 이용하여 pitch 변화에 따른 CT 영상의 공간 분해능을 측정하여 비교하였다. 그리고, PET source consists of a solid radioactive cylinder phantom을 사용하여 Pitch 변화에 따른 Fusion 영상의 SUV값을 산출하여 PET/CT 영상에서 SUV값이 변하였는지 확인하였다. 결과 : 2slice CT scanner에서는 Pitch가 0.7~1.3까지는 방사선량이 크게 떨어지나 1.5~1.9까지는 방사선량의 감소가 작아졌으며 Pitch값이 커질수록 환자의 피폭선량이 작아지는 것을 알 수 있었다. 그리고 Pitch값의 증가에 따른 SUV값의 변화는 거의 없었으며. Pitch값이 PET SUV값에 영향을 주지 않는다는 것을 알 수 있었다. Pitch의 변화가 CT 영상에도 크게 영향을 주지 않는 것을 알 수 있었다. 결론 : 위의 결과로 PET/CT를 사용하는 병원은 영상의 왜곡이 없고 PET SUV값에 영향을 주지 않는 범위 내에서 각 병원에 맞는 Pitch값을 찾아서 환자의 피폭 경감을 위해 노력해야 할 것이다. 그리고 Multi-detector를 가진 CT scanner인 경우에 모두 해당 될 것이라 생각되며 향후 다른 장비에서도 이와 같은 실험이 필요하다 하겠다.

  • PDF

CT선량지표의 원리와 선량감소 방안에 관한 연구 (Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique)

  • 김정수;권순무;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.51-61
    • /
    • 2015
  • 모든 방사선 검사는 검사를 결정하고 실행하는 과정에서 정당성이 확보되어야하고 피폭선량과 영상의 화질에 대한 최적화가 이루어져야 할 뿐만 아니라 ALARA의 원칙에 따라 최소의 방사선을 사용하여 최적의 임상 정보를 얻을 수 있어야 한다. CT 검사는 방사선 검사 중에서 많은 피폭을 환자에게 조사하는 검사이다. 특히 방사선 민감도가 높은 소아 환자의 CT 검사 있어서는 특별한 주의가 필요하다. 임상에서 CT선량에 대한 정확한 이해와 정보는 환자에게 불필요한 방사선 피폭을 줄이고 안전한 검사를 제공하기 위해 절대적으로 필요하다. 이에 본 연구에서는 여러 선행 연구의 고찰을 통하여 CT의 피폭선량에 대한 개념을 확인하고 CT장치의 선량 저감화를 위한 각 파라미터의 이해와 American Association of Physicists in Medicine (AAPM)report 204에서 소개하고 있는 환자의 사이즈에 따른 피폭선량의 보정방법인 Size-Specific Dose Estimates(SSDE)와 XR 25의 개념을 이해하고자 한다.

의료기관의 환자 피폭선량 관리 실태조사 (A Survey of the Management of Patient Dose at Medical Center)

  • 전고은;진계환
    • 한국방사선학회논문지
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2009
  • 방사선동위원소 I-131을 이용한 질병의 치료는 핵의학 분야의 아주 중요한 부분을 차지하고 있다. 환자피폭에서 주의사항으로는 첫째 진료목적상 필요로 하는 선량을 초과하지 말아야 한다. 둘째 불필요한 피폭을 억제하여야 한다. 셋째 방사선을 사용하지 않고 동일한 진료목적을 달성할 수 있는지 면밀히 검토해봐야 한다. 이러한 목적을 달성하기 위해서는 환자에 대한 피폭선량의 평가가 필요하다. 본 연구에서는 치료병실 환자의 안전관리를 도모하고자 에어샘플러를 이용하여 공기를 채집하고, 채집한 시료의 방사선을 HPGe 감마카운터로 측정하였다. 치료병실에서 채집한 시료의 I-131 측정결과의 최고값은 $404.11Bq/m^3$, 평균값은 $228.27Bq/m^3$, 최저값은 $126.17Bq/m^3$ 이었다.

  • PDF

심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가 (Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea)

  • 김정수;이종혁;정혜경;김정민;조병렬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.27-33
    • /
    • 2016
  • 심장혈관 조영술과 인터벤션은 현대 성인병의 증가로 급격히 증가하고 있다. 심장혈관 인터벤션은 장시간 동일 부위에 방사선을 조사하는 검사로 방사선으로 인한 피부상해를 일으킬 수 있다. 본 연구에서는 의료기관의 심장혈관 인터벤션의 진단참조준위를 조사하여 환자의 피폭선량을 감소시키는 도구로 사용하고자 한다. 본 연구는 147명의 환자에서 심장혈관 조영술과 인터벤션을 대상으로 누적 투시시간, 누적 투시면적선량, 영상촬영을 위한 면적선량, 누적 면적선량, 공기커마, 동영상 수, 총 영상 수에 대한 정보를 획득하여 진단참조준위를 설정하였다. 심장혈관 조영술의 진단참조준위와 인터벤션의 진단참조준위에 해당하는 면적선량 값은 각각 $44.4 Gy{\cdot}cm2$$298.6Gy{\cdot}cm2$로 나타났고 투시시간에 대한 진단참조준위는 각각 191.5 sec와 1935.3 sec로 나타났다. 진단참조준위는 반드시 넘으면 안 되는 값은 아니다. 하지만 진단참조준위를 제정하여 의료 기관에서 사용하고 있는 선량의 참조 값을 설정하고 이를 검토하는 과정은 환자의 불필요한 피폭선량을 감소시키는데 기여할 것이다.

Standing Whole Spine 검사 시 체질량지수 (BMI)에 따른 전방 및 후방장기의 흡수선량 평가 (Estimation of Absorbed Dose for Anterior and Posterior Organs with Body Mass Index in Standing Whole Spine Examination)

  • 심지나;이용구;이영진
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.147-151
    • /
    • 2016
  • Standing Whole Spine 검사는 많은 병원에서 자동노출제어장치 (automatic exposure control, AEC)를 사용하고 있어 체질량지수 (body mass index, BMI)에 따라 방사선량이 조절되는 특징이 있으며, 이를 통하여 환자 별 측정 DAP (dose area product) 값을 얻을 수 있다. 하지만, 검사 시 장기의 위치에 따른 흡수선량에 관한 연구는 크게 이루어지지 않고 있으며, 이에 본 연구에서는 Standing Whole Spine 검사 시 환자의 두께정보를 대표하는 BMI와 장기의 위치에 따른 흡수선량의 분포를 평가하고자 한다. 연구의 목적을 위하여 측정된 DAP값을 이용하여 PCXMC에서 환자의 5곳의 장기를 선정 (갑상샘, 유방, 심장, 콩팥, 이자)하여 선량을 계산하였다. 결과적으로, 측정된 DAP값은 BMI에 따라 증가하는 경향을 보였지만 전방 장기인 갑상샘, 유방, 그리고 심장에서는 BMI에 따라 장기선량이 감소하는 경향을 보였다. 또한 후방장기인 콩팥과 이자에서는 BMI와 아무런 상관관계를 가지지 않았다. 결론적으로, 본 연구결과를 통하여 Standing Whole Spine 검사 시 BMI와 장기의 위치에 따라 방사선의 영향이 다르게 나타남을 증명하였다.