• Title/Summary/Keyword: patient exposure dose

Search Result 383, Processing Time 0.026 seconds

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Evaluation of Image Quality for Diagnostic Digital Chest Image Using Ion Chamber in the Total Mastectomy (변형근치유방절제술 환자의 Ion chamber 변화에 따른 디지털 흉부 영상의 화질 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Park, Hyong-Hu;Kim, Donghyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.204-210
    • /
    • 2013
  • The patients who had been operated total mastectomy are different from general women in their breasts thickness due to breast surgery. As a result, digital chest image from total mastectomy patients will be different attenuation. The main objective for this study is to show that a proper Ion chamber standard combination measuring MTF which is objective basis for Digital image, when be x-ray for total mastectomy patient. We have designed the unique number that shown Left is 1, Right is 2, Center is 3 and have put the edge phantom on detector ion chamber. Lastly, we have obtained experiment images. The evaluations of all image quality have measured by 50% MTF of spatial resolution and absorption dose using Matlab(R2007a). The result showed that average exposure condition, MTF value, absorption dose for 1+3 and 2+3 combinations were 2.745 mAs, 1.925 lp/mm, 0.688 mGy. Consequently, that showed high MTF, DQE and low dose than other combinations. Therefore, a proper changes of ion chambers are able to improve image quality and to reduce radiation exposure when be X-ray for total mastectomy patients. Also, it will be possible to standard for application chamber combination and utilization on clinical detection.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Clinical Application of 3-D Conformal Radiotherapy for Carcinoma of the Ethmoid Sinus : I. Comparative Analysis Between Conventional 2-D and 3-D Conformal Plans (사골동 종양의 3-차원 입체조형치료 : I. 2차원 치료계획과 3차원 치료계획의 비교분석)

  • Lee Sangwook;Kim Gwi Eon;Keum Ki Chang;Park Hee Chul;Cho Jae Ho;Han Soung Uk;Lee Kang Kyu;Suh Chang Ok;Hong Won Pyo;Park In Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.287-296
    • /
    • 1997
  • Purpose : This is study of whether 3-D conformal radiotherapy for carcino-mas of the ethmoid sinus were better than those treated with conventional 2-D plan, Materials and Methods : The 3-D conformal treatment Plans were compared with conventional 2-D plans in 4 patients with malignancy of the ethmoid sinus. Isodose distribution, dose statistics, and dose volume histogram of the planning target volume were used to evaluate differences between 2-D and 3-D plans. In addition. the risk of radiation exposure of surrounding normal critical organs are evaluated by means of point dose calculation and dose volume histogram. Results : 3-D conformal treatment plans for each patient that the better tumor coverages by the planning target volume with improved dose homo-geneity, compared to 2-D conventional treatment Plans in the same Patient. On the other hand, the radiation dose distributions to the surrounding nor-mal tissue organs, such as the orbit and optic nerves are not significantly reduced with our technique, but a substantial sparing in the brain stem and optic chiasm for each patient. Conclusion : Our findings represented the potential advantage of 3-D treatment planning for dose homogeniety as well as sparing of the normal tissue surrounding the tumor. However, further investigational studies are required to define the clinical benefit.

  • PDF

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

A Comparative Study of CTDI and the Effective Dose and the SNR according to the Area in the Abdominal CT (복부CT에서 면적에 따른 CTDI와 유효선량 및 SNR의 비교 연구)

  • Choi, Sung-Jun;Kang, Jun-Guk;Kim, Su-In;Kim, Youn-Ho;Lee, Do-Gyeong;Jung, Jin-Gyung;Cho, Ar-A;Jang, Jae-Hyeok;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.245-252
    • /
    • 2015
  • To obtain the best SNR (signal to noise ratio) due to changes in CTDI (computed tomography dose index) made for the purpose of setting the optimum image obtained by reducing the dose in abdominal CT. Abdominal CT scans of 59 patients a $400-499cm^2$ (n = 12), $500-599cm^2$ (n = 21), $600-699cm^2$ (n = 17), $700-799cm^2$ (n = 9) were separated by four groups and the effective dose was used in the Excel to get the area of the patient using the ImageJ program. Patients of CTDI, DLP, SNR, the effective dose were analyzed. Abdominal CT area was increased to 13 mGy in CTDI is 7.3 mGy, DLP to 732 in $394.4mGy{\cdot}cm$, also effective dose was 5.9 mSv increase in 11mSv. SNR is 15 dB was maintained at 12.7. CTDI according to the average of the abdominal area of 8.9 mGy, the average of the DLP was $481.54mGy{\cdot}cm$, the effective dose is calculated to be 7.2 mSV. Effective dose was calculated by multiplying the load factor of DLP in the abdomen showed no statistically significant difference of (p < .05), there was a significant difference in SNR (p > . 05). To improve image quality of abdominal CT scan image in consideration of the CTDI according to the volume of the patient it should be able to reduce the radiation exposure of the patients.

Evaluation of Every Other Day - Cone Beam Computed Tomography in Image Guided Radiation Therapy for Prostate Cancer (전립선암의 영상유도방사선치료 시 격일 콘빔 CT 적용의 유용성 평가)

  • Park, Byoung Suk;Ahn, Jong Ho;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.289-295
    • /
    • 2014
  • Purpose : Cone Beam Computed Tomography(CBCT) in Image Guided Radiation Therapy(IGRT), Set-up error can be reduced but exposure dose of the patient due to CBCT will increase. Through this study, we are to evaluate by making a scenario with the implementation period of CBCT as every other day. Materials and Methods : Of prostate cancer patients, 9 patients who got a Intensity Modulated Radiation Therapy(IMRT) with CBCT in IGRT were analyzed. Based on values corrected by analyzing set-up error by using CBCT every day during actual treatment, we created a scenario that conducts CBCT every other day. After applying set-up error values of the day not performing CBCT in the scenario to the treatment planning system(Pinnacle 9.2, Philips, USA) by moving them from the treatment iso-center during actual treatment, we established re-treatment plan under the same conditions as actual treatment. Based on this, the dose distribution of normal organs and Planning Target Volume(PTV) was compared and analyzed. Results : In the scenario that performs CBCT every other day based on set-up error values when conducting CBCT every day, average X-axis : $0.2{\pm}0.73mm$, Y-axis : $0.1{\pm}0.58mm$, Z-axis : $-1.3{\pm}1.17mm$ difference was shown. This was applied to the treatment planning to establish re-treatment plan and dose distribution was evaluated and as a result, Dmean : -0.17 Gy, D99% : -0.71 Gy of PTV difference was shown in comparison with the result obtained when carrying out CBCT every day. As for normal organs, V66 : 1.55% of rectal wall, V66 : -0.76% of bladder difference was shown. Conclusion : In case of a CBCT perform every other day could reduce exposure dose and additional treatment time. And it is thought to be able to consider the application depending on the condition of the patient because the difference in the dose distribution of normal organs, PTV is not large.