• 제목/요약/키워드: passive power factor correction

검색결과 42건 처리시간 0.03초

인버터에어컨에 능동역률개선회로 적용에 관한 연구 (A Study On The Application Of Active Power Factor Correction Circuit In Inverter Airconditioner)

  • 김태덕;배영돈;박윤서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.306-308
    • /
    • 1996
  • The demands of minimizing the reactive power and reducing the current harmonics are increasing nowdays. The inverter airconditioner needs high inductive power and it operates with wide load ranges. Conventionally, an huge LC passive filter is used in airconditioner to improve the power factor and to reduce current harmonics which doesn't give good results. In this paper, a design of active power factor correction(APFC)circuit for inverter airconditioner is described. To improve the P.F and reduce the current THD, average current controlled APFC is designed and tested. The problems of APFC implementation, their solution and testing results are described.

  • PDF

저감된 DC Link Capacitor 부피를 가지는 역률 개선 Valley-Fill Flyback 컨버터의 설계 및 구현 (Practical Design and Implementation of a Power Factor Correction Valley-Fill Flyback Converter with Reduced DC Link Capacitor Volume)

  • 김세민;강경수;공성재;유혜미;노정욱
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.277-284
    • /
    • 2017
  • For passive power factor correction, the valley fill circuit approach is attractive for low power applications because of low cost, high efficiency, and simple circuit design. However, to vouch for the product quality, two dc-link capacitors in the valley fill circuit should be selected to withstand the peak rectified ac input voltage. The common mode (CM) and differential mode (DM) choke should be used to suppress the electromagnetic interference (EMI) noise, thereby resulting in large size volume product. This paper presents the practical design and implementation of a valley fill flyback converter with reduced dc link capacitors and EMI magnetic volumes. By using the proposed over voltage protection circuit, dc-link capacitors in the valley fill circuit can be selected to withstand half the peak rectified ac input voltage, and the proposed CM/DM choke can be successfully adopted. The proposed circuit effectiveness is shown by simulation and experimentally verified by a 78W prototype.

수동 역률 보상회로를 이용한 LED 센서등 회로의 개발 (Development of LED sensor lights circuit by passive power factor correction circuit)

  • 박종연;유진완;이학범
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.109-114
    • /
    • 2012
  • In this paper, We studied LED(Light Emitted Diode) sensor lights system using PIR(Pyroelectric Infrared Ray) sensor, CdS and MCU(Micro Controller Unit). And applied the valley fill circuit to improve the power factor. We designed the amplifier for each sensor and the LED driver for constant current which is the buck converter. Also, we proposed the algorithm of LED control by each sensors using MCU. Experimental results showed that power factor is 92% with valley fill circuit.

  • PDF

형광등용 전자식 안정기에 적합한 수동 역률개선회로의 제안 및 특성 개선에 관한 연구 (Improved Passive Power Factor Correction Circuits of Electronic Ballasts for fluorescent lamps)

  • 채균;류태하;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2795-2797
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both voltage-fed and current-fed electronic ballast. The proposed PFC circuits use valley-fill(VF) type DC-link stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant capacitors. In current-fed type, the charge pump capacitors are connected with the additional secondary-side of the power transformer. The measured PF and THD are higher than 0.99 and 15% for all proposed PFC circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for implementing cost-effective electronic ballast.

  • PDF

A Novel Soft-Switching Two-Switch Flyback Converter with a Wide Operating Range and Regenerative Clamping

  • Kim, Marn-Go;Jung, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.772-780
    • /
    • 2009
  • A novel soft-switching two-switch flyback converter is proposed in this paper. This converter is composed of two active power switches, a flyback transformer, a blocking diode, and two passive regenerative clamping circuits. The proposed converter has the advantages of a low cost circuit configuration, a simple control scheme, a high efficiency, and a wide operating range. The circuit topology, analysis, design considerations, and experimental results of the new flyback converter are presented.

Basic Study of a Phase-Shifted Soft Switching High-Frequency Inverter with Boost PFC Converter for Induction Heating

  • Kawaguchi, Yuki;Hiraki, Eiji;Tanaka, Toshihiko;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.192-199
    • /
    • 2008
  • This paper is mainly concerned with a high frequency soft-switching PWM inverter suitable for consumer induction heating systems. The proposed system is composed of a soft switching chopper based boost PFC converter stage with passive snubber and phase shifted PWM controlled full bridge ZVZCS high frequency inverter stage. Its fundamental operating performances are illustrated and evaluated in the experimental results. Its effectiveness is substantially proved on the basis of the experimental results from a practical point of view.

능동 블리더 회로를 적용한 조광기 호환용 LED 구동회로에 관한 연구 (A Study on LED Driver Compatible with Triac-dimmer Employing Active Bleeder)

  • 염봉호;홍성수;김택우
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.297-302
    • /
    • 2014
  • In this paper, a LED driver compatible with TRIAC-dimmer applying active bleeder is proposed. If TRIAC-dimmer is connected with LED driver, flicker phenomenon occurs by TRIAC malfunction. In order to prevent this problem, a current over holding current must flow into TRIAC. Therefore, additional circuit compatible with TRIAC-dimmer is required to provide enough current. Passive bleeder has power loss in whole operation period. The proposed circuit apply a valley-fill circuit for power-factor-correction and a novel active bleeder detecting malfunction point of TRIAC. Therefore, it prevent malfunction of TRIAC-dimmer and have advantage of higher efficiency than passive bleeder. To verify the validity of proposed circuit, 13W-lighting LED driver prototype has been proposed.

전원 전압의 불평형과 고조파 전류 및 역률을 동시에 보상하는 통합형 능동 전력필터 (Unified Active Power Filter Compensating For Source Voltage Unbalance/Current Harmonics and Power Factor Simultaneously)

  • 이종건;석줄기;이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.103-105
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor simultaneously in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

SINGLE-PHASE ACTIVE RECTIFIER WITH HIGH POWER FACTOR CAPABILITY FOR INVERTER AIR-CONDITIONER

  • Jung, Yong-Chae;Kwon, Kyung-Ahn
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.677-682
    • /
    • 1998
  • A Single-phase Active Rectifier (SAR) [4-6] with high power factor capability is adopted to satisfy the international harmonic current standards such as IEC 1000-3-2. To minimize the input current distortion and to apply the control IC, such as FA5331, UC3854, ML4821 and so forth, the new adequate sensing circuits of the input voltage and current are proposed. There are tow methods applicable the SAR to inverter air-conditioner from the viewpoint of both efficiency and cost. The selecting methods of the passive components are presented for the two approaches. Using the determined components, the loss analyses are carried out. The prototype SAR circuits of these two approaches with 3kW power consumption are built and the operation and performance of the circuits with power factor correction capability are verified through the experimental results.

  • PDF

고조파 저감과 입력역률 개선을 위한 전력용 능동필터의 설계 (The Design of Active Power Filter with the Performance of Harmonic Suppression and Input Power Factor Correction)

  • 박해원;최성관;김호;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.375-377
    • /
    • 2000
  • In this paper, voltage controlled APF(Active Power Filter) is introduced to improve power factor and reduce harmonic generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. According to the results of simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF