• Title/Summary/Keyword: passive circuit

Search Result 463, Processing Time 0.029 seconds

Common Mode Noise Reduction for an LLC Resonant Converter by Using Passive Noise Cancellation

  • Ryu, Younggon;Kim, Sungnam;Jeong, Geunseok;Park, Jaesu;Kim, Duil;Park, Jongwook;Kim, Jingook;Han, Ki Jin
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • This paper describes the application of a passive noise cancellation method to a prototype inductor-inductor-capacitor (LLC) resonant converter by placing a compensation winding in a transformer to reduce common mode noise. The connection method for the compensation winding is investigated. A circuit analysis is implemented for the displacement currents between the primary and secondary windings in the transformer. The analyzed displacement currents are verified by performing a circuit simulation and a proper compensation winding connection that reduces common mode noise is found. The measurement results show that common mode noise is reduced effectively up to 20 dB in the 1 to 7 MHz frequency region for the prototype LLC resonant converter by using the proposed passive noise cancellation method.

Passive and Active Circuits design of High Order Low-pass Filter using Elliptic Function (타원비수를 이용한 고차 저역통과 필터의 수동 및 능동회로 설계)

  • 윤창훈;신건순;김동용
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.2
    • /
    • pp.140-147
    • /
    • 1987
  • In this paper, seven-order elliptic low-pass passive network is synthesized by using doublyterminated ladder network is directly transformed into the active network which has the advantage of low sensitivity and can be realized conveniently. The circuit simulation results of passive network and active network synthesized with FDNR and Leap-frog technique are compared, and it is proved that the two rest work has the same characteristics.

  • PDF

Implementation of Passive Telemetry RF Sensor System Using Unscented Kalman Filter Algorithm (Unscented Kalman Filter를 이용한 원격 RF 센서 시스템 구현)

  • Kim, Kyung-Yup;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1861-1868
    • /
    • 2008
  • In this paper, Passive Telemerty RF Sensor System using Unscented Kalman Filter algorithm(UKF) is proposed. General Passive Telemerty RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Passive Telemerty RF Sensor System adopts Integrated Circuit type, but there are defects like complexity of structure and limit of large power consumption in some cases. In order to overcome these kinds of faults, Passive Telemetry RF Sensor System based on inductive coupling principle is proposed in this paper. Because passive components R, L, C have stray parameters in the range of high frequency such as about 200[KHz] used in this paper, Passive Telemetry RF Sensor System considering stray parameters has to be derived for accurate model identification. Proposed Passive Telemetry RF Sensor System is simple because it consists of R, L and C and measures the change of environment like pressure and humidity in the type of capacitive value. This system adopted UKF algorithm for estimation of this capacitive parameter included in nonlinear system like Passive Telemetry RF Sensor System. For the purpose of obtaining learning data pairs for UKF Algorithm, Phase Difference Detector and Amplitude Detector are proposed respectively which make it possible to get amplitude and phase between input and output voltage. Finally, it is verified that capacitive parameter of proposed Passive Telemetry RF Sensor System using UKF algorithm can be estimated in noisy environment efficiently.

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

Performance of Passive Boost Switched Reluctance Converter for Single-phase Switched Reluctance Motor

  • Ahn, Jin-Woo;Lee, Dong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.505-512
    • /
    • 2011
  • A novel passive boost power converter forsingle-phaseswitched reluctance motor is presented. A simple passive circuit is proposed comprisingthree diodes and one capacitor. The passive circuitis added in the front-end of a conventional asymmetric converter to obtain high negative bias. Based on this passive network, the terminal voltage of the converter side is a general DC-link voltage level in parallel mode up to a double DC-link voltage level in series mode. Thus,it can suppress the negative torque generation from the tail current and improve the output power. The results of the comparative simulation and experiments forthe conventional and proposed converter verify the performance of the proposed converter.

Design of SR Drive Using Passive Converter for Hydraulic Pump System (패시브 컨버터를 적용한 유압유니트용 SRM 제어기 설계)

  • Seok, Seung-Hun;Liang, Jianing;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.863_864
    • /
    • 2009
  • Design and drive characteristics of SR drive for hydraulic pump system using passive converter is presented in this paper. In oder to get the high performance, a simple passive circuit is added in the front-end of a conventional asymmetric converter, which consists of three diodes and one capacitor. This passive converter has the high demagnetization voltage, to reduce the demagnetization time. Futhermore optimal turn-off angle for the proposed passive converter is proposed. According to motor speed and current, an optimal turn-off angle can be achieved by look-up table to reduce torque ripple. The characteristic of proposed hydraulic pump system using passive converter is verified by simulation and experimental results.

  • PDF

Analysis of HVDC Inverter and Application of Objective Functions for the Optimal Filter Design (직류송전 인버터의 필터 최적설계를 위한 해석 및 목적함수의 선정)

  • 오성철;정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.82-89
    • /
    • 2001
  • This paper proposes several methods to analyze dynamic and static characteristics of HVDC inverter system. The characteristic analysis is essential of the controller and filter design of the HVDC inverter system. Dynamic characteristic can be analyzed with EMTP simulation and static characteristic can be obtained by solving newly proposed load flow equation which includes the filter and load characteristic. New simple per-phase-equivalent circuit is also proposed. In this circuit, HVDC inverter is considered as a current source depending on the on-off status of switch. Dynamic and static characteristic can be analyzed by the proposed per-phase-equivalent circuit. For the optimal filter design, various performance criteria are proposed. The performance index, based on the per-phase-equivalent circuit, is calculated. Voltage harmonics and filter power loss are selected as criteria. Optimization procedure is explained to find optimal passive filter parameters.

  • PDF

Ring Hybrid Coupler using Microstrip Line with Via Transition (비아 트랜지션을 갖는 마이크로스트립 선로를 이용한 링 하이브리드 결합기)

  • Kim, Young;Sim, Seok-Hyun;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.658-663
    • /
    • 2013
  • In this paper, a microstrip line implementation using via transition and its application of multilayer compact ring hybrid coupler are presented. This transition is the sandwich structure with via hole to connect two microstrip lines in different layer. For designing a compact RF/Microwave passive circuit, the microstrip line using via-hole transition is proposed to reduce a size of microwave circuit with long transmission line. For the validation of the microstrip line with via-hole transition, the multilayer ring hybrid coupler is implemented at center frequency of 2 GHz. The measured performances are in good agreement with simulation results and about 50% size reduction compare to conventional ring hybrid coupler.

Analysis of magnetic field mitigation by a passive loop around an overhead power transmission line (수동루프에 의한 가공송전선로 자계 저감효과 해석)

  • Kim, J.H.;Shin, M.C.;Lee, B.K.;Park, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.212-214
    • /
    • 2003
  • A passive loop is considered to be a cheap and easy way to be realized among the magnetic field mitigation methods. So this paper evaluates and quantizes systematically the effectiveness of a passive loop on mitigating magnetic field(M-field) and examines the feasibility and problems in adoption. To do so, first, we explain the principles of M-field mitigation through a passive loop and derive formulas for 2-D M-field analysis. Next this paper simulates the M-field mitigation patterns for a flat type 1-circuit transmission line installed a passive loop.

  • PDF

Design and Effects of Power Factor Correction Circuit for Inverter Air-Conditioner (인버터 에어컨용 능동역률보상회로 설계 및 효과)

  • 박병욱;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.27-30
    • /
    • 1998
  • In this paper, the inverter air-conditioner with Power Factor Correction(PFC) circuit is Presented for obtaining the good system efficiency and cost merit compared with the conventional inverter air-conditioner. The detailed design procedures for getting the optimal passive components are implemented. Through the simulation and experimental results, it is shown that the system efficiency can be improved. Using the designed components, the prototype system is builted and tested to verify the additional good performances of the proposed circuit.

  • PDF