• Title/Summary/Keyword: passive and active

Search Result 2,177, Processing Time 0.031 seconds

Studies on vibration control effects of a semi-active impact damper for seismically excited nonlinear building

  • Lu, Zheng;Zhang, Hengrui;Masri, Sami F.
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.95-110
    • /
    • 2019
  • The semi-active impact damper (SAID) is proposed to improve the damping efficiency of traditional passive impact dampers. In order to investigate its damping mechanism and vibration control effects on realistic engineering structures, a 20-story nonlinear benchmark building is used as the main structure. The studies on system parameters, including the mass ratio, damping ratio, rigid coefficient, and the intensity of excitation are carried out, and their effects both on linear and nonlinear indexes are evaluated. The damping mechanism is herein further investigated and some suggestions for the design in high-rise buildings are also proposed. To validate the superiority of SAID, an optimal passive particle impact damper ($PID_{opt}$) is also investigated as a control group, in which the parameters of the SAID remain the same, and the optimal parameters of the $PID_{opt}$ are designed by differential evolution algorithm based on a reduced-order model. The numerical simulation shows that the SAID has better control effects than that of the optimized passive particle impact damper, not only for linear indexes (e.g., root mean square response), but also for nonlinear indexes (e.g., component energy consumption and hinge joint curvature).

A Study on the Performance of Active Anti-Rolling Tank Stabilizer System (능동형 횡동요 감쇠장치의 성능에 관한 연구)

  • Choi, Chan-Moon;Ahn, Jang-Young;Lee, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.138-143
    • /
    • 2004
  • This experimental paper deals with the performance of tanks that are turned the active A.R.T(Anti-Rolling Tank) when the fluid transfers from wing tank to the opposite tank by the power developed by the automatic control system (INTERING Stabilizer), which was installed in the fishery training ship T/S. A - RA (G/T:990 tons) of Cheju National University. In this paper, the author has tested the performance of INTERING Stabilizer for the signals obtained by the inclinometer in irregular waves and compared with the results obtained in passive mode operation at stop and at various ship speeds. The performances of the system were confirmed the results as follows through the tests: 1. The average amplitude and significant roll (${\pi}$1/3) of the passive and active mode operations in the condition of stoped engine and underway were obtained 8.30$^{\circ}$, 4.37$^{\circ}$, 8.30$^{\circ}$, 4.37$^{\circ}$, and 5.01$^{\circ}$, 4.36$^{\circ}$, 5.50$^{\circ}$, 5.10$^{\circ}$, respectively. 2. The rates of performance of active mode operations were carried out during a sea trial in the condition of stop engine and underway resulted in 47.5%, 12.7%, respectively, therefore the active mode operation estimated to be improved more than passive mode operation. 3. Active - A.R.T by INTERING Stabilizer didn't affect the amplitude of pitching.

A New Low Cost Hybrid Power Filter for Thyristor-Controlled Rectifier Load (싸이리스터 정류부하를 위한 새로운 저원가 복합형 전력필터)

  • 한성룡;김수근;석원엽;조정구;송의호;전희종
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.24-29
    • /
    • 2004
  • A new low cost hybrid active filter for thyristor-controlled rectifier load is presented to overcome the high cost problem of the active or the other hybrid active filters. The proposed hybrid active filter which consists of tuned (5th and 7th harmonics) LC passive filters, power factor improvement(PFI) capacitor bank, and active filter compensates power factor as well as harmonic currents. Since most of harmonic currents are filtered by the passive filter and most of reactive power is compensated by the PFI capacitor bank, the power rating of active filter can be minimized, resulting in cost minimization of the proposed hybrid active filter. A 300kVA hybrid active filter system is implemented and tested using 1MVA thyristor rectifier load to verify the operation and performance.

Analysis of Receiving Strength according to the Attachment Location of RFID tag in Palletized Unit-load of Agricultural Products

  • Jong Min Park;Eon Uck Kang;Hyun Mo Jung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.211-221
    • /
    • 2023
  • This study was conducted as a basic study for the selection of tags suitable for logistics management in the palletized unit-load unit and the development of various technologies to activate the palletized unit-load shipment of agricultural products through local APCs. Three types of passive RFID tags of UHF 900 MHz and one type of active RFID tag of 2.4 GHz band designed and manufactured through this study were used to analyze the receiving strength according to the tag's attachment location and distance of the palletized unit-load of agricultural products. In the passive RFID tag, there was a large difference in receiving strength by the tag's attachment location and a large amount of data loss depending on the distance within 30 m, whereas, in the active RFID tag, it was superior to the passive tags in terms of both receiving strength and data loss. Therefore, active tags are desirable from the perspective of multiple identification of warehouses with large spaces in relation to the application of RFID tags for palletized unit-loads of agricultural products, but the development of low-power technologies such as software wakeup power management as well as hardware to minimize battery power consumption is necessary.

Active-passive control of flexible sturctures using piezoelectric sensor/actuator (압전형 센서/액추에이터를 이용한 진동구조물의 능동-수동제어)

  • 고병식
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.313-325
    • /
    • 1995
  • Two active/passive vibration dampers were designed to control a cantilever beam first mode of vibration. The active element was a piezoelectric polymer, polyvinlidene fluoride (PVDF). The passive damping was provided by the application of a viscoelastic layer on the surface of the steel beam. Two substantially different damper configurations were designed and tested. One damper consisted of a piezoelectric actuator bonded to one face of the beam, with a viscoelastic layer applied to the other surface of the beam. The second one was composed of a layer viscoeastic layer with one surface bonded to the beam, and with other being constrained by nine piezoelectric actuators connected in parallel. A control law based on the sign of the angular velocity of the cantilever beam was implemented to control the beam first mode of vibration. The piezoelectric sensor output was digitally differentiated to obtain the transverse linear velocity, and its sign was used in the control algorith. Two dampers provided the system a damping increase of a factor of four for the first damper and three for the second damper. Both dampers were found to work well at low levels of vibration, suggesting that they can be used effectively to prevent resonant vibrations in flexible structure from initiating and building up.

  • PDF

The effect of active and passive confining pressure on compressive behavior of STCC and CFST

  • Nematzadeh, Mahdi;Fazli, Saeed
    • Advances in concrete construction
    • /
    • v.9 no.2
    • /
    • pp.161-171
    • /
    • 2020
  • In this paper, an experimental study was conducted on the compressive behavior of steel tube confined concrete (STCC) and concrete-filled steel tube (CFST) columns with active and passive confinement. To create active confinement in the STCC and CFST specimens, an innovative method was used in this study, in which by applying pressure on the fresh concrete, the steel tube was laterally pretensioned and the concrete core was compressed simultaneously. Of the benefits of this technique are improving the composite column behavior, without the use of additives and without the need for vibration, and achieving high prestressing levels. To achieve lower and higher prestressing levels, short and long term pressures were applied to the specimens, respectively. Nineteen STCC and CFST specimens in three groups of passive, short-term active, and long-term active confinement were subjected to axial compression, and their mechanical properties including the compressive strength, modulus of elasticity and axial strain were evaluated. The results showed that the proposed method of prestressing the STCC columns led to a significant increase in the compressive strength (about 60%), initial modulus of elasticity (about 130%) as well as a significant reduction in the axial strain (about 45%). In the CFST columns, the prestressing led to a considerable increase in the compressive strength, a small effect on the initial and secant modulus of elasticity and an increase in the axial strain (about 55%). Moreover, increased prestressing levels negligibly affected the compressive strength of STCCs and CFSTs but slightly increased the elastic modulus of STCCs and significantly decreased that of CFSTs.

Combined Effects of Gastrocnemius Stretch and Tibialis Anterior Resistance Exercise in Subjects with Limited Ankle Dorsiflexion

  • Lee, Jihyun;Cynn, Heonseock;Shin, Areum;Kim, Bobeen
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.10-15
    • /
    • 2021
  • Objective: Limited ankle dorsiflexion is related to ankle injuries. There are various exercises to increase the flexibility of the gastrocnemius for improving the passive range of motion in ankle dorsiflexion. However, to performances in daily activities and athletic sports and higher efficiency of walking and running, both ankle dorsiflexion passive and active range of motion are needed. To investigate the effects of combined gastrocnemius stretching and tibialis anterior resistance exercise on ankle kinematics (passive and active range of motion of ankle dorsiflexion) and tibialis anterior muscle activity in subjects with limited ankle dorsiflexion. Design: Cross-sectional single-group repeated measures design. Methods: Fourteen subjects with limited ankle dorsiflexion were recruited (in the right ankle in 7 and the left ankle in 7). All subjects performed gastrocnemius stretching alone and tibialis anterior resistance exercise after gastrocnemius stretching. The passive and active range of motion of ankle dorsiflexion were measured after interventions immediately. The tibialis anterior activity was measured during active range of motion of ankle dorsiflexion measurement. Results: There was no significant difference of ankle dorsiflexion passive range of motion between gastrocnemius stretching alone and the tibialis anterior resistance exercise after gastrocnemius stretching. The tibialis anterior resistance exercise after gastrocnemius stretching significantly increased active range of motion of ankle dorsiflexion compared to gastrocnemius stretching alone (p<0.05). The tibialis anterior resistance exercise after gastrocnemius stretching significantly increased tibialis anterior activity better than did gastrocnemius stretching alone. Conclusions: Thus, subjects with limited ankle dorsiflexion should be encouraged to perform tibialis anterior resistance exercises.

Eating habits and dietary supplement utilization according to food-related lifestyle among Korean adults: a cross-sectional study

  • EunJung Lee;Jin A Jang;Ji-Myung Kim
    • Korean Journal of Community Nutrition
    • /
    • v.29 no.4
    • /
    • pp.253-264
    • /
    • 2024
  • Objectives: This study investigated the association between eating habits and the utilization of dietary supplements (DSs) according to food-related lifestyle (FRL) among Korean adults. Methods: This study included a total of 300 participants (150 men and 150 women) in their 20s to 60s living in Seoul and Gyeonggi Province. We identified two groups by factor and cluster analysis: an 'active pursuit' group and a 'passive pursuit' group. Differences in eating habits and DS utilization between the two groups were analyzed by chi-square test and t-test. Logistic regression analysis was used to analyze the effect of variables on DS consumption according to FRL. Results: There were significant differences between the two groups in terms of age, alcohol drinking frequency, total dietary score, change in DS consumption after coronavirus disease 2019, and current DS consumption (P < 0.05). The proportion who perceived many health benefits of DSs was higher in the 'active pursuit' group than in the 'passive pursuit' group (P = 0.003). The most commonly consumed type of DSs was multivitamins & minerals for the 'active pursuit' group, and omega-3 fatty acids for the 'passive pursuit' group. The 'an active pursuit' group consumed DSs 2.93 times more (95% confidence interval [CI]: 1.44-5.97) compared to the 'passive pursuit' group, after adjusting for confounders. In the 'active pursuit' group, the health pursuit (odds ratio [OR] = 6.54, 95% CI: 1.44-29.61) and rational consumption pursuit factors (OR = 0.26, 95% CI: 0.08-0.83) were associated with DS consumption, whereas only the health pursuit factor had a significant association (OR = 5.37, 95% CI: 2.08-13.88) within the 'passive pursuit' group. However, total dietary score and DSs consumption did not show a relationship. Conclusions: By understanding the consumption characteristics of DSs according to FRL, this can serve as basic data necessary for promoting health through the utilization of DSs and healthy behaviors.

The Effect of Continuous Passive Motion and Continuous Active Motion on Joint Proprioception After Total Knee Replacement (슬관절전치환술 후 연속수동운동(CPM)과 연속능동운동(CAM) 적용이 관절 고유수용감각에 미치는 영향)

  • Yang, Jin-Mo;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.17 no.1_2
    • /
    • pp.41-52
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the effects of continuous passive motion(CPM) and continuous active motion(CAM) on proprioception of the knee after total knee replacement(TKR). Methods: Twenty patients with TKR were randomly allocated into two groups, the CPM group(n=10) and the CAM group(n=10). All subjects were evaluated for levels of pain, passive range of motion and angle reproduction of the knee. An angle reproduction test was used to assess the proprioceptive deficit. Two types of angle reproduction test were used: a passive angle reproduction(PAR) test and an active angle reproduction(AAR) test. The relevant examinations were performed before and after intervention(on the 5th day and the 10th day). The statistical significance were calculated using a t-test and a one-way repeated ANOVA. Results: A pre-intervention significant difference was not found between the two groups. Significantly better results were before and after the intervention at 10 days, for the PAR(flexion direction) test; however, only in the CAM group. There were no significant difference, either before or after the intervention, for the AAR test(flexion and extension direction) in both group. Both groups experienced similar levels of pain and passive range of knee motion before and after the intervention. Conclusion: This study revealed that CAM was a better effect to restore position sense of the knee joint after TKR.

  • PDF

A Study on the Investment Review of Passive and Active Elements through Comparison of Energy Demand and Generation Variation of Zero Energy Building (제로에너지건축물의 에너지 소요량과 생산량 비교를 통한 패시브와 액티브 요소의 투자 검토 연구)

  • Lee, Soon-Myung;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.13-22
    • /
    • 2018
  • At the time when zero energy building is expected to be generalized, this study examines whether the investment in the passive element or the active element is more effective in terms of energy in the construction process of zero energy building. In other words, the effect of energy demand by passive element and the change of energy generation by active element are examined in terms of the same investment cost. The purpose of this study is to examine the change of energy demand by passive element and the change of energy generation by active element in zero energy building and to make reasonable investment decision by comparing energy with cost aspect. For this purpose, we selected the buildings to be subjected to energy simulation and derive the required energy amount and energy generation amount by using meteorological data of four regions in Korea. The change of energy demand and energy generation according to the change of application condition was derived. In order to compare and analyze the changes in energy demand and generation at the same cost standard through price survey and quotation of window and photovoltaic power generation equipment.