• Title/Summary/Keyword: particle detection

Search Result 310, Processing Time 0.025 seconds

DESIGN OF COMPACT PARTICLE DETECTOR SYSTEM USING FPGA FOR SPACE PARTICLE ENVIRONMENT MEASUREMENT (FPGA를 이용한 우주 입자환경 관측용 초소형 입자검출기 시스템 설계)

  • Ryu, K.;Oh, D.S.;Kim, S.J.;Kim, H.J.;Lee, J.J.;Shin, G.H.;Ko, D.H.;Min, K.W.;Hwang, J.A.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.2
    • /
    • pp.155-166
    • /
    • 2007
  • We have designed a high resolution proton and electron telescope for the detection of high energy particles, which constitute a major part of the space environment. The flux of the particles, in the satellite orbits, can vary abruptly according to the position and solar activities. In this study, a conceptual design of the detector, for adapting these variations with a high energy resolution, was made and the performance was estimated. In addition, a parallel processing algorithm was devised and embodied using FPGA for the high speed data processing, capable of detecting high flux without losing energy resolution, on board a satellite.

Monitoring of the Volcanic Ash Using Satellite Observation and Trajectory Analysis Model (인공위성 자료와 궤적분석 모델을 이용한 화산재 모니터링)

  • Lee, Kwon-Ho;Jang, Eun-Suk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.13-24
    • /
    • 2014
  • Satellite remote sensing data have been valuable tool for volcanic ash monitoring. In this study, we present the results of application of satellite remote sensing data for monitoring of volcanic ash for three major volcanic eruption cases (2008 Chait$\acute{e}$n, 2010 Eyjafjallaj$\ddot{o}$kull, and 2011 Shinmoedake volcanoes). Volcanic ash detection products based on the Moderate Resolution Imaging Spectro-radiometer (MODIS) observation data using infrared brightness temperature difference technique were compared to the forward air mass trajectory analysis by the HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model. There was good correlation between MODIS volcanic ash image and trajectory lines after the volcanic eruptions, which support the feasibility of using the integration of satellite observed and model derived data for volcanic ash forecasting.

Track Distiribution of Recoil Protons in PN-3 Dosimeters Etched in NaOH Solution (NaOH 용액에 의해 부식된 PN-3 선량측정계에서의 되튕긴 양성자의 궤적 분포)

  • Yoo, Done-Sik;Sim, Kwang-Souk
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.129-139
    • /
    • 1991
  • The method of etching tracks in PN-3 dosimeter has been applied to tracks of recoil protons from a neutron source. Both the etch and the detection response of PN-3 has been studied as a function of etched-track diameters against various parameters. We could obtain very useful informations about charge, energy, and mass of particles and the relationship between the track etching rate and the track forming procedure in order to analyze the particle recorded in the solid state track detector. The best etching condition could be found by means of changing the etching circumstances for various energies and particles in order to detect the charged particle accurately. It could be influenced widely that the polymer plastic detector could develep the detecting technique for the low energy level neutron and could be used as a neutron dosimeter in the radiation field such as the nuclear power station, the medical institute and the nondtructive testing institute.

  • PDF

Characterization of a Cell Line HFH-T2, Producing Viral Particles, from Primary Human Fetal Hepatocytes Infected with Hepatitis B Virus

  • Shim, Jae-Kyoung;Kim, Dong-Wook;Chung, Tae-Ho;Kim, June-Ki;Suh, Jeong-Ill;Park, Chun;Lee, Young-Choon;Chung, Tae-Wha;Song, Eun-Young;Kim, Cheorl-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.186-192
    • /
    • 2001
  • A primary culture of human fetal hepatocytes was obtained through a therapeutic abortion process at 26 weeks of gestation period. More than $10^8$ cells were seeded on a plastic plate. These hepatocytes were infected with hepatitis B virus (HBV). The HBV was purified from serum of one chronic HBV carrier. Transformed hepatocytes were subcultured in a 10% FBS-supplemented medium. The morphology of the transformed cell was epithelial-like. The cells from the first pass showed signs of early proliferation and had a latent period of more than 3 months after 6-7 passages. After the rest period, the transformed cell proliferated actively and they were subcultured every three days. Transformed hepatocytes were characterized by detection of the HBV transcript by RT-PCR. The secretion of virions from transformed cells was investigated by PCR with the cell medium. Two types of virions secreted into the culture medium were examined by using the transmission electron microscope. Another approach to study the secretion of virions in to culture medium was carried out with HBV antibody. HBsAg was detected in the culture medium of transformed cells using ELISA and Western blot analyses. These data suggested that the human fetal hepatocyte cell line has been established by infection of HBV, in which this cell line secreted viral particles into the culture medium.

  • PDF

THE ANALYSIS ON SPACE RADIATION ENVIRONMENT AND EFFECT OF THE KOMPSAT-2 SPACECRAFT(II): SINGLE EVENT EFFECT (아리랑 2호의 방사능 환경 및 영향에 관한 분석(II)- SINGLE EVENT 영향 중심으로 -)

  • 백명진;김대영;김학정
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.163-173
    • /
    • 2001
  • In this paper, space radiation environment and single event effect(SEE) have been analyzed for the KOMPSAT-2 operational orbit. As spacecraft external and internal space environment, trapped proton, SEP(solar energetic particle) and GCR(galactic cosmic ray) high energy Protons and heavy ions spectrums are analyzed. Finally, SEU and SEL rate prediction has been performed for the Intel 80386 microprocessor CPU that is planned to be used in the KOMPSAT-2. As the estimation results, under nominal operational condition, it is predicted that trapped proton and high energetic proton induced SBU effect will not occur. But, it is predicted that heavy ion induced SEU can occur several times during KOMPSAT-2 3-year mission operation. KOMPSAT-2 has been implementing system level design to mitigate SEU occurrence using processor CPU error detection function of the on-board flight software.

  • PDF

Fabrication and NOx Gas Sensing Properties of LaMeO3 (Me = Cr, Co) by Polymeric Precursor Method (Polymeric Precursor법에 의한 LaMeO3 (Me = Cr, Co)의 제조 및 NOx 가스 검지 특성)

  • Lee, Young-Sung;Shimizu, Y.;Song, Jeong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.21 no.8
    • /
    • pp.468-475
    • /
    • 2011
  • [ $LaMeO_3$ ](Me = Cr, Co) powders were prepared using the polymeric precursor method. The effects of the chelating agent and the polymeric additive on the synthesis of the $LaMeO_3$ perovskite were studied. The samples were synthesized using ethylene glycol (EG) as the solvent, acetyl acetone (AcAc) as the chelating agent, and polyvinylpyrrolidone (PVP) as the polymer additive. The thermal decomposition behavior of the precursor powder was characterized using a thermal analysis (TG-DTA). The crystallization and particle sizes of the $LaMeO_3$ powders were investigated via powder X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), and particle size analyzer, respectively. The as-prepared precursor primarily has $LaMeO_3$ at the optimum condition, i.e. for a molar ratio of both metal-source (a : a) : EG (80a : 80a) : AcAc (8a) inclusive of 1 wt% PVP. When the as-prepared precursor was calcined at $700^{\circ}C$, only a single phase was observed to correspond with the orthorhombic structure of $LaCrO_3$ and the rhombohedral structure of $LaCoO_3$. A solid-electrolyte impedance-metric sensor device composed of $Li_{1.5}Al_{0.5}Ti_{1.5}(PO_4)_3$ as a transducer and $LaMeO_3$ as a receptor has been systematically investigated for the detection of NOx in the range of 20 to 250 ppm at $400^{\circ}C$. The sensor responses were able to divide the component between resistance and capacitance. The impedance-metric sensor for the NO showed higher sensitivity compared with $NO_2$. The responses of the impedance-metric sensor device showed dependence on each value of the NOx concentration.

Real-time Monitoring of Colloidal Nanoparticles using Light Sheet Dark-field Microscopy Combined with Microfluidic Concentration Gradient Generator (μFCGG-LSDFM)

  • Choe, Hyeokmin;Nho, Hyun Woo;Park, Jonghoon;Kim, Jin Bae;Yoon, Tae Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.365-370
    • /
    • 2014
  • For real-time monitoring of colloidal nanoparticles (NPs) in aqueous media, a light sheet type dark-field microscopy system combined with a microfluidic concentration gradient generator (${\mu}FCGG$-LSDFM) was developed. Various concentrations of colloidal Au NPs were simultaneously generated with the iFCGG and characterized with the LSDFM setup. The number concentrations and hydrodynamic size distributions were measured via particle counting and tracking analysis (PCA and PTA, respectively) approaches. For the 30 nm Au NPs used in this study, the lower detection limit of the LSDFM setup was 3.6 ng/mL, which is about 400 times better than that of optical density measurements under the same ${\mu}FCGG$ system. Additionally, the hydrodynamic diameter distribution of Au NPs was estimated as $39.7{\pm}12.2nm$ with the PTA approach, which agrees well with DLS measurement as well as the manufacturer's specification. We propose this ${\mu}FCGG$-LSDFM setup with features of automatic generation of NP concentration gradient and real-time monitoring of their physicochemical characteristics (e.g., number concentration, and hydrodynamic size distribution) as an important component of future high-throughput screening or high-content analysis platforms of nanotoxicity.

Complexation of Adiponectin-encoding Plasmid DNA with Rosiglitazone-loaded Cationic Liposomes

  • Davaa, Enkhzaya;Jeong, Ui-Hyeon;Shin, Baek-Ki;Choi, Soon-Gil;Myung, Chang-Seon;Park, Jeong-Sook
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.6
    • /
    • pp.357-362
    • /
    • 2010
  • To enhance therapeutic effects of insulin-sensitizing adipokine, ADN gene and potent agonists, rosiglitazone for the $PPAR{\gamma}$, cationic liposomes as non-viral vectors were formulated. The particle size and zeta potential of drug loaded and unloaded cationic liposomes were investigated. The complex formation between cationic liposomes and negatively charged plasmid DNA was confirmed and the protection from DNase was observed. In vitro transfection was investigated in HepG2, HeLa, and HEK293 cells by mRNA expression of ADN. Encapsulation efficacy of rosiglitazone-loaded liposomes was determined by UV detection. Particle sizes of cationic liposomes were in the range of 110-170 nm and those of rosiglitazone-loaded cationic liposomes were in the range of 130-180 nm, respectively. Gel retardation of complexes indicated that the complex was formed at weight ratios of cationic lipid to plasmid DNA higher than 20:1. Both complexes protected plasmid DNA from DNase either drug free or drug loading. Encapsulation efficiency of rosiglitazone-loaded emulsion was increased by drug dose. The mRNA expression levels of ADN were dose-dependently increased in cells transfected with plasmid DNA. Therefore, cationic liposomes could be potential co-delivery system for drug and gene.

A Real-time Particle Filtering Framework for Robust Camera Tracking in An AR Environment (증강현실 환경에서의 강건한 카메라 추적을 위한 실시간 입자 필터링 기법)

  • Lee, Seok-Han
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.597-606
    • /
    • 2010
  • This paper describes a real-time camera tracking framework specifically designed to track a monocular camera in an AR workspace. Typically, the Kalman filter is often employed for the camera tracking. In general, however, tracking performances of conventional methods are seriously affected by unpredictable situations such as ambiguity in feature detection, occlusion of features and rapid camera shake. In this paper, a recursive Bayesian sampling framework which is also known as the particle filter is adopted for the camera pose estimation. In our system, the camera state is estimated on the basis of the Gaussian distribution without employing additional uncertainty model and sample weight computation. In addition, the camera state is directly computed based on new sample particles which are distributed according to the true posterior of system state. In order to verify the proposed system, we conduct several experiments for unstable situations in the desktop AR environments.

Determination of thyroid hormones by solid-phase extraction using high performance liquid chromatograph/diode array detector/electro-spray ionization mass spectrometry in urine samples (HPLC/DAD/ESI-MS 및 고체상 추출법을 이용한 뇨시료중 갑상선 호르몬 분석)

  • Kwak, Sun Young;Moon, Myeong Hee;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.519-528
    • /
    • 2006
  • An analytical method for the determination of thyroid hormones in urine samples has been studied by using solid-phase extraction and high-performance liquid chromatography/diode array detector/electro-spray mass spectrometry. Seven thyroid hormones were successfully separated by gradient elution on the reverse phase Hypersil ODS column (4.6 mm I.D., 100 mm length, particle size $5{\mu}m$) with ammonium formate buffer and acetonitrile, and UV spectra and mass fragment could be confirmed. The extraction recoveries of thyroid hormones in the urine samples (pH 3) were in the range of 89.0-113.1% with solid-phase extraction by C18, followed by elution with 4 ml of methanol/ammonium hydroxide (9 : 1). The calibration curves showed good linearity with the correlation coefficients ($r^2$) varying from 0.992 to 0.998 and the detection limits of all analytes were obtained in the range of 2-4 ng/ml (3.8-13.0 pmol/ml).