• 제목/요약/키워드: partial dentures

검색결과 210건 처리시간 0.017초

유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교 (Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application)

  • 전인식;김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析) (Photoelastic Stress Analysis of Fixed Partial Dentures)

  • 조원행
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

임프란트 지지 국소의치의 임상적 연구 (Clinical study of implant supported removable partial dentures)

  • 박원희
    • 대한치과의사협회지
    • /
    • 제47권4호
    • /
    • pp.184-190
    • /
    • 2009
  • OBJECTIVE The purpose of clinical study was to evaluate the survival of dental implants used in restoring patients with implant supported removable partial dentures (ISRPDs) of different configurations. MATERIALS AND METHODS The sample consisted of 20 consecutively treated partially edentulous patients, who, between 2003 and 2008, had a total of 84implants placed in different arch sites and who were treated with ISRPDs. The mean age was 57 years. Mean follow up time from delivery of ISRPDs was 3 years 2 months (range, 1 to 6 years). Osseointegration failure, postoperative complication of dental prosthesis, and the success rate of ISRPDs were retrospectively evaluated using clinical and radiographic examination. RESULT The overall implant survival rate was 100%. During follow up, the one clasp of removable partial denture was broken in 1 year11 months after prosthesis delivery. All patients were satisfied with their prosthesis. CONCLUSIONS Implant supported removable partial dentures could serve as favorable prognosis. Careful patient selection, with an appropriate maintenance and recall system, is recommended to obtain satisfactory results.

  • PDF

회전삽입로를 이용한 국소의치에 관한 임상적연구 (A Clinical Study on Rotational Path Removable Partial Denture)

  • 김광남
    • 대한치과보철학회지
    • /
    • 제21권1호
    • /
    • pp.67-72
    • /
    • 1983
  • Path of insertion(1) can be defined that the direction of movement of an appliance from the point of initial contact of its rigid parts with the supporting teeth to the place of final rest. Krol(2) described that in the conventional path of insertion, all the rests are seated more or less simultaneously but in the use of the rotational path one segment of the partial denture is seated first then the remainder of the prosthesis is rotated into position. The rotational path of insertion is limited primarily to the tooth borne prosthesis. Its great advantages are the elimination of anterior clasps to improve ethetic and reduction of tooth coverage to minimize plaque accumulation. Either a rigid minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface below the height of contour as indicated at a o-degree tilt. A specially designed rest in conjunction with this retentive component satisfies the basic requirements of clasp design. The purpose of this study was a clinical evaluation of rotational path removable partial dentures. Author delivered rotational path removable partial dentures to three different cases of patients and evaluated function of the dentures, difficulties of removal and insertion of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of the rotational path removable partial dentures was excellent.

  • PDF

국가고시 교과목에 따른 치기공과 교육과정의 분석 (Analysis of curriculum related to subjects of Korean Dental Technicians' Licensing Examination)

  • 배봉진;이화식
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.399-415
    • /
    • 2006
  • This research collected the curriculum for Dental Technology from a total of 20 schools-eighteen 3-year colleges and two 4-year colleges all in Korea. We divided 4 groups as regions from 20 colleges, and we compared the credit of university students who finished all the required courses and want to apply for a national examination and the credit to be had from another educational institution. As a result of this analysis, we get the conclusion below: 1. In the curriculum, average credit are shown like this order: Science of Dental materials 5.45 Orthodontics Technology 4.10 Dental Morphology 3.80 Oral Anatomy 3.05 Dental Health Science 2.45 Public Health Science 2.40 These show that the credit of fundamental studies, which is in order to take Dental Prosthetics, is increased. 2. In the curriculum, average credit are shown like this order: Crown and Bridge Technology 7.25 Removable Partial Dentures Technology 6.55 Complete Dentures Technology 6.40 Dental Ceramics 4.95 Inlay Technology 2.30 3. In the curriculum, average credit are shown like this order: Crown and Bridge Technology(Lab) 5.90 Removable Partial Dentures Technology(Lab) 5.35 Complete Dentures Technology(Lab) 5.30 Dental Ceramics(Lab) 4.35 Average points between regions in the subject of a national written exam are mostly similar, but the deviation among Science of Dental Materials, Crown and Bridge Technology, Removable Partial Dentures Technology, and Complete Dentures Technology is large. And in the practical technique exam, the deviation among Crown and Bridge Technology(Lab), Removable Partial Dentures Technology(Lab), and Complete Dentures Technology(Lab) is great.

  • PDF

편측성으로 설계된 하악 유리단 국소의치에서 직접유지장치의 설계 변화에 따른 광탄성 응력 분석에 관한 연구 (A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE DESIGNED UNILATERALLY WITH DIFFERENT DIRECT RETAINERS)

  • 손홍석;계기성
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.25-42
    • /
    • 1992
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a unilateral distal extention removable partial dentures with five kinds of the direct retainers, that is, the bilaterally designed bar clasp of the cross-arch lingual bar and the unilaterally designed bar clasp, circumferential clasp, mini-Dalbo attachment, and telescope retainer. A photoelastic model for mandible was made of the epoxy resin(PL-1) and hardner (PLH-1) with the acrylic resin teeth used and was coated with plastic cement-1 at the lingual surface of the model, and then five kinds of removable partial dentures were set, A unilateral vertical load of about 16Kg was applied on the first molar and the stress pattern of the photoelastic model under each condition was analyzed by the reflective circular polariscope. The following results were obtained: 1. The conventional removable partial denture with the bilaterally cross arch lingual bar produced the most favorable stress distribution on the residual ridge and supporting structure of abutment teeth than the unilaterally designed removable partial dentures. 2. The unilaterally designed removable partial denture with the bar clasp produced the stress distribution on the residual ridge, except sligtly higher stress concentration on the supporting structure of the abutment teeth, similar to the conventional removable partial denture with the bilaterally designed cross arch lingual bar. 3. On the unilaterally designed removable partial dentures, the bar clasp produced greater stress distribution on the residual ridge and supporting structure of the abutment teeth than the circumferential clasp. 4. On the unilaterally designed removable partial dentures, the mimi-Dalbo attachment produced relatively higher stress concentration on the residual ridge, but produced lesser stress concentration on the supporting structure of the abutment teeth than the other direct retainers. 5. On the unilaterally designed removable partial dentures, the telescope retainer produced uniform stress distribution on the residual ridge, but produced higher stress concentration at the root apex of the terminal abutment tooth than the other direct retainers. 6. On the unilaterally designed removable partial dentures the circumferential clasp and telescope retainer produced slightly higher stress concentration on the residual ridge and supporting structure of the abutment teeth than the bar clasp and mini- Dalbo attachment.

  • PDF

유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구 (Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures)

  • 임순호
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구 (Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance)

  • 박기범;신수연
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.61-69
    • /
    • 2020
  • 목적: 하악 제2소구치와 제2대구치를 지대치로 한 지르코니아 고정성 국소의치에서 지대치 간 거리가 파절저항성에 미치는 영향을 조사하였다. 연구 재료 및 방법: Cameleon S zirconia block과 Luxen S2 zirconia block으로 각 재료별 지대치 간 거리를 달리 하여 CS군과 S2군으로 나누어 표기하였으며, 소결된 지르코니아 고정성 국소의치를 임시접착시멘트를 이용하여 에폭시 레진 다이에 합착하였다. 이후, 가공치 교합면에 직경 6 mm 강철구를 위치시켜 로드셀 5.0 kN의 universal testing machine에서 크로스 헤드 속도 1.0 mm/min로 압력을 가하여 파절저항성을 측정하였다. 결과: 지르코니아 고정성 국소의치의 파절저항성은 지대치 간 거리에 큰 영향을 받지 않았다. CS군에서 지대치 간 거리가 15 mm인 경우가 13 mm와 17 mm인 경우보다 파절저항성이 유의하게 높았다(P < 0.05). S2군에서는 파절저항성이 세 군 간에 유의한 차이가 없었다(P > 0.05). 결론: 하악 제2소구치와 제2대구치를 지대치로 한 지르코니아 고정성 국소의치에서 지대치 간 거리는 지르코니아의 종류에 따라 파절저항성에 영향을 줄 수 있다.

가철성 국소의치의 임상적 상태에 대한 평가 (Evaluation of clinical status of removable partial dentures)

  • 양동석;조욱;정창모;전영찬;윤미정
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.320-327
    • /
    • 2009
  • 연구목적: 가철성 국소의치의 장기적 예후를 보증하고자 하는 많은 노력에도 불구하고, 부적절한 제작 및 유지관리로 인해 가철성 국소의치와 연관된 합병증은 여전히 관측되고 있다. 이에 본 연구에서는 가철성 국소의치의 임상적 상태를 조사하여 보철 진료의 임상적 참고자료와 후학연구의 기초자료로 도움이 되고자 하였다. 연구 재료 및 방법: 2008년 1월에서 8월까지 부산대학교병원 치과 보철과에 내원한 환자 중 가철성 국소의치를 사용 중인 성인을 대상으로 가철성 국소의치와 지대치에 연관된 임상적 상태를 조사 평가하였다. 결과 및 결론: 본 연구의 결과는 다음과 같았다. 1. 전체 가철성 국소의치의 추정수명은 4.0년이었고, 평균 장착 기간은 5.3년이었다. 2. 가철성 국소의치 성공, 실패 평가에서 45개의 보철물이 실패했으며. 전체 369개의 지대치 중 18개 (4.9%)의 지대치가 상실되었다. 3. 가철성 국소의치의 상, 하악 위치, Kennedy 분류, 대합치의 조건에 따른 추정 수명은 차이가 없었으며, 성공률과 실패율도 차이가 없었다 (P > .05). 4. 가철성 국소의치의 주연결장치는 상악에서 palatal plate 주연결장치 (55%)가 가장 많이 설계되었으며, 하악에서는 linguoplate 주연결장치 (52%), lingual bar 주연결장치 (45.3%) 순으로 조사되었다. 5. 가철성 국소의치의 직접유지장치는 circumferential type (74%), bar type (15%), 기타 (11%) 순으로 조사되었다. 6. 전체 140개의 I급과 II급 가철성 국소의치 중 63%의 보철물에 간접유지장치가 설계되어 있었다. 7. 보철물의 주된 결함은 과도한 구치부 인공치 마모 (27.9%), 보철물의 손상 (23.2%), 안정성의 부족 (22.6%) 순으로 발생하였으며, 전체 보철물의 81%가 최소한 1개의 결함을 가지고 있었다.

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.