Inhomogeneous bonding state modeling for vibration analysis of explosive clad pipe

  • Cao, Jianbin;Zhang, Zhousuo;Guo, Yanfei;Gong, Teng
    • Steel and Composite Structures
    • /
    • 제31권3호
    • /
    • pp.233-242
    • /
    • 2019
  • Early detection of damage bonding state such as insufficient bonding strength and interface partial contact defect for the explosive clad pipe is crucial in order to avoid sudden failure and even catastrophic accidents. A generalized and efficient model of the explosive clad pipe can reveal the relationship between bonding state and vibration characteristics, and provide foundations and priory knowledge for bonding state detection by signal processing technique. In this paper, the slender explosive clad pipe is regarded as two parallel elastic beams continuously joined by an elastic layer, and the elastic layer is capable to describe the non-uniform bonding state. By taking the characteristic beam modal functions as the admissible functions, the Rayleigh-Ritz method is employed to derive the dynamic model which enables one to consider inhomogeneous system and any boundary conditions. Then, the proposed model is validated by both numerical results and experiment. Parametric studies are carried out to investigate the effects of bonding strength and the length of partial contact defect on the natural frequency and forced response of the explosive clad pipe. A potential method for identifying the bonding quality of the explosive clad pipe is also discussed in this paper.

친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구 (Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas)

  • 임동영;최은혁;배성우;최상태;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치 (Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater)

  • 이문형;김찬오
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

카본 도포에 따른 Cu-Epoxy 접촉면에서 발생하는 크랙방지에 관한 연구 (A Study on the Prevention of Crack Generated in Interface Cu and Epoxy with Painting of Carbon)

  • 송재주;김성훈;황종선;박종광;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제14권7호
    • /
    • pp.578-583
    • /
    • 2001
  • The bushing for high voltage and large and power should endure weight of itself and force of pushing from contact with circuit breaker. Like this, epoxy mold bushing has to be strong without fault. However, the external circumstances and internal factors was caused by partial discharge, flashover and dielectric breakdown. Therefore, to remove external factor of defect and to prevent the internal cracks and cavity generated from the contraction on interface of Cu-Epoxy, we should form semi-conductive layer on Cu bar by carbon. Then, the PD properties and the insulation qualities of epoxy mold type bushing was able to improved by roles of cushions for the direction of diameter and by effects fo natural sliding like as separated from conductor for the direction of length. So, in this work, we could prove the method of semi-conductive layer in making the long conductor.

  • PDF

Air-coupled ultrasonic tomography of solids: 2 Application to concrete elements

  • Hall, Kerry S.;Popovics, John S.
    • Smart Structures and Systems
    • /
    • 제17권1호
    • /
    • pp.31-43
    • /
    • 2016
  • Applications of ultrasonic tomography to concrete structures have been reported for many years. However, practical and effective application of this tool for nondestructive assessment of internal concrete condition is hampered by time consuming transducer coupling that limits the amount of ultrasonic data that can be collected. This research aims to deploy recent developments in air-coupled ultrasonic measurements of solids, described in Part 1 of this paper set, to concrete in order to image internal inclusions. Ultrasonic signals are collected from concrete samples using a fully air-coupled (contactless) test configuration. These air coupled data are compared to those collected using partial semi-contact and full-contact test configurations. Two samples are considered: a 150 mm diameter cylinder with an internal circular void and a prism with $300mm{\times}300mm$ square cross-section that contains internal damaged regions and embedded reinforcement. The heterogeneous nature of concrete material structure complicates the application and interpretation of ultrasonic measurements and imaging. Volumetric inclusions within the concrete specimens are identified in the constructed velocity tomograms, but wave scattering at internal interfaces of the concrete disrupts the images. This disruption reduces defect detection accuracy as compared with tomograms built up of data collected from homogeneous solid samples (PVC) that are described in Part 1 of this paper set. Semi-contact measurements provide some improvement in accuracy through higher signal-to-noise ratio while still allowing for reasonably rapid data collection.

고분자 애자 오손정도의 전자파 신호 분석 (Signal Classification of Electromagnetic Wave for Contaminated Degree on Polymer Insulator)

  • 박재준;최인혁;정명연;이승욱;서의원;가평현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.662-665
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high-voltage electrical apparatus However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time-frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this paper analyzes the electromagnetic waves emitted from PD using Wavelet transform. This paper experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. This method is shown to be useful for detecting prediction of contamination degree.

  • PDF

카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석 (Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination)

  • 박재준
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.113-118
    • /
    • 2004
  • 기존의 누설전류기법에서 한층 진일보된 비접촉식 수신용 안테나를 이용하여 복잡한 지역과 광범위한 지역에서 효율적인 고분자 애자의 오손정도를 진단하기 위하여 본 연구를 착수하였다. 착수된 연구는 가공된 챔버 내 설치된 고분자애자에 인위적으로 카올린과 소금을 혼합후 증류수에 혼합하여 인공 오손실시 후 방사전자파와 스페트럼 그리고 부분방전전하량을 동시에 측정 후 전자파 신호에 대한 카올린의 오손정도에 대한 특징추출을 위하여 다우비치 이산웨이블렛 변환기법에 적용 후 각각의 통계적인 파라미터의 특징을 추출하였다.

  • PDF

ETA를 통한 연구실험실 콘센트회로의 전기재해 분석 (Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA)

  • 김두현;김성철;박종영;김상철
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

혈행화된 부분층 두개골피판을 이용한 상악골 종양 적출 환자에서의 안와하벽 재건술 증례 (Inferior Orbital Wall Reconstruction with Vascularized Partial Thickness Calvarial Bone Flap in Three Cases of Maxillary Tumor)

  • 신상호;이윤정;김준식;김남균;이경석
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.49-54
    • /
    • 2009
  • 상악골 악성종양의 경우 적출 후 골편들을 이식해 상악동 전체를 재건하는 경우는 재발이 많아 잘 시행하지 않는다. 이러한 이유로 안와하연의 재건을 통해 안구 및 안면윤곽만을 재건하는데, 저자들이 시행한 혈행화된 부분 두께의 골이식(vascularized split thickeness calvarium)은 술기방법에 있어 골피판이 혈관경에서 쉽게 분리되는 성질이 있어 시행에 주의가 필요하고 혈관경을 포함한 temporalis muscle이 부피감을 주므로 미용상 불리한 점이 있는 반면에 골편의 높은 생존율이 보장된다는 장점과 공여부의 합병증이 적다는 장점을 가진다. 또한 술후 복시 현상이나 안구함몰이 관찰되지 않았다는 점이 합리적인 술기임을 지지해준다. 따라서 측두동맥 및 정맥을 혈관경으로 하는 혈행화된 두정골 부분층 이식술은 안와하벽을 재건하는데 있어 안전하게 시행가능 한 술기였음을 보고하는 바이다.