• Title/Summary/Keyword: partial changes

Search Result 817, Processing Time 0.03 seconds

Performance Analysis of Noncoherent FH-BFSK System in Partial-Band Noise Jamming (부분대역 잡음 재밍환경에서의 비동기 FH-BFSK 시스템의 성능 분석)

  • 이철호;유흥균;김기근;최영균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.429-436
    • /
    • 2000
  • In this paper, the performance of a orthogonal noncoherent FH-BFSK communication system in the presence of partial band noise jamming is analyzed. Also bit error rate(BER) is studied when jamming bandwidth ratio to overall spread spectrum bandwidth,$\rho$, changes according to processing gain(PG). The performance is investigated by numerical analysis and computer simulation of SPW. Even if PG is high, required performance could not gain because error floor occurs when JSR is 10 dB and SNR is under 10 dB. PG can be obtained to acquire a required BER according to $\rho$ when SNR is above 12 dB.

  • PDF

Real Effect of pH on CIE L*, a*, and b*, of Loins during 24 h Chilling of Beef Carcasses

  • Min, J.S.;Kim, I.S.;Yoon, Y.T.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.2
    • /
    • pp.279-282
    • /
    • 2002
  • Twenty six male Hanwoo (Korean cattle) carcasses were measured for pH, temperature and instrumental color changes of loins during 24 h post-mortem carcass chilling at $4^{\circ}C$ in the cooler. The average internal temperature of loins was about $5^{\circ}C$ after 24 h of chilling, and with the exclusion of those with an ultimate pH>6.0 (dark-cutters), the average pH value was 5.5. When all carcasses were considered for the partial correlation coefficient between color and pH, with the temperature effect excluded, CIE $L^*$, $a^*$ and $b^*$ seemed to be affected significantly by pH during chilling process (p<0.001). However, when carcasses with dark-cutting condition were excluded, the correlation coefficients were much lower. In contrast, when the partial correlation coefficients between color and temperature, excluding the effect of pH on them, were analyzed, the relationship between color and temperature did not change much after values of DFD (dark, firm, dry) beef were excluded. The results suggested that the known interrelationship of color and pH in chilled beef loins be mainly due to the influence of temperature on pH and color.

A study on the structural changes and the TSC characteristics of epoxy composites cured with acid-anhydride (산무수물 경화된 에폭시 복합체의 구조변화와 TSC특성에 관한 연구)

  • 왕종배;이준웅
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.32-41
    • /
    • 1994
  • In this study, the TSC spectroscopy has been applied to investigate the influence of structural change due to a process of curing reaction on the electrical properties of epoxy composites cured with acid-anhydride. Five TSC peaks appeared in -160-250[.deg.C]: in the low temperature region below glass transition temperature(T$\_$g/), three relaxation mode peaks due to action of side chains, substitution group or terminal groups have been observed, a peak associated with T$\_$g/, appeared in 110[.deg. C] and p peak due to ionic space charges located in 150[.deg.C]. Each peak was separated into elementary peaks by the partial polarization procedure, and the distribution of activation energy and relaxation time were analized to clearify the origin of each peak. Also, overaboundantly added hardener separated a .betha. peak near 10[.deg. C] into two peaks of .betha.$\_$1/(10.deg. C) and .betha.$\_$2/(20.deg. C) according to increasement of forming field, and the separated hardener was oxidated thermally with increasing surrounding temperatures. The expansion of the free volume need in molecular motion and the reduction of the structural packing density through thermal oxidation process increased TSC between .alpha. peak and .betha. peak and decreased T$\_$g/.

  • PDF

The Low Temperature Deposition of CrN Films by the AIP Method (아크 이온플레이팅법에 의한 저온 CrN 합성)

  • Cho, Yong K.;Kim, Sang K.;Lee, Won B.;Kim, Sung W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.20 no.2
    • /
    • pp.78-83
    • /
    • 2007
  • CrN coatings were deposited by cathodic arc ion plating method on the SKD11 steel substrates. Atmosphere temperature of $350^{\circ}C$, arc current of 90 A, nitrogen partial pressure of 1.0-5.3 Pa, and negative bias voltage of 30-135 V were selected. The characteristics of microstructure were investigated with XRD. Hardness, adhesion and friction coefficient measured by microhardness tester, scratch tester, and ball on disk tribometer. Microstructures depended on nitrogen partial pressure and bias voltage. The preferred orientation of the films was changed from (200) to (111) with decreasing pressure and increasing bias voltage. Adhesion properties related with microstructure, but microstructure changes slightly influenced on hardness and friction properties. The critical load.($Lc_1$) and hardness of CrN films deposited at 5.3 Pa, -30 V condition were 55 N(HF1), $2157{\pm}47\;Hk_{0.025}$. The friction coefficient were about 0.5 under dry condition.

The Study on Temperature Measurement of Warm Needling Using Stainless Steel Needle and Gold Needle (금침과 스테인레스침을 이용한 온침에서의 부위별 온도측정 연구)

  • Yeo, Sujung
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.178-184
    • /
    • 2013
  • Objectives : The warm needling technique is the method combining the effects of acupuncture needle with those of moxibustion. We need to standardize the characteristics of the warm needling technique, in order to get more systematic and objective results in operation and effects and then get more clinical abilities in these fields. Methods : In this study, using labview system on the warm needling technique, we measured and compared partial temperature changes according to the kind of needle. We studied relations of moxa cones of various sizes with the peak combustion temperature. Results and Conclusions: When we measured the warm needling's partial temperature, temperature measured at 1 and 2 cm below the head, according to the kind of needle, gold needle got the higher result on the peak than SS304 stainless steel needle. In the case of combustion of the moxa cones, cones weighing 0.4 g and 0.8 g, respectively, and the apex ignition method with gold needle showed the higher result than the apex ignition method with stainless steel needle, when we measured the effective stimulus time at 2 cm below the head and the mean temperature during the effective stimulus time. Although more research to standardize the characteristics of the warm needling technique will be needed, we suggest, according to these results, that warm needling of gold needle combined with moxa cone of 0.4 or 0.8 g is effective.

Effects of low-head dam removal on benthic macroinvertebrate communities in a Korean stream

  • Kil, Hye-Kyung;Bae, Yeon-Jae
    • Animal cells and systems
    • /
    • v.16 no.1
    • /
    • pp.69-76
    • /
    • 2012
  • This study was conducted to examine how a low-head dam removal (partial removal) could affect benthic macroinvertebrate communities in a stream. Benthic macroinvertebrates and substrates were seasonally sampled before and after dam removal (March 2006-April 2007). Benthic macroinvertebrates and substrates were quantitatively sampled from immediately upstream (upper: pool) and downstream (lower: riffle) sites, the location of the dam itself (middle), and immediately above the impoundment (control: riffle). After the removal, species richness and density of benthic macroinvertebrates as well as the EPT group (Ephemeroptera, Plecoptera and Trichoptera) increased to higher levels than those before the removal, while functional feeding groups and habitat orientation groups changed more heterogeneously at the upper site. At the lower site, species richness and density decreased somewhat immediately after dam removal, which was associated with an increase of silt and sand, but recovered after monsoon floods which helped to enhance substrate diversity at the upper site. Decreased dominance index and increased diversity index in both the upper and lower sites are evidence of positive effects from the dam removal. In conclusion, we suggest that even a partial removal of a dam, resulting in increased substrate diversity in the upper site, could sufficiently help rehabilitate lost ecological integrity of streams without major habitat changes.

An Efficient Partial Reanalysis Algorithm for the Locally Changed Structures (부분적 강성 변화에 따른 효율적 부분 재해석 알고리즘)

  • Kim Chee-Kyeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.459-467
    • /
    • 2004
  • This paper presents an efficient reanalysis algorithm, named PRAS (Partial Reanalysis algorithm using Adaptable Substructuring), for the partially changed structures. The algorithm recalculates directly any displacement or member force under consideration in real time without a full reanalysis in spite of local changes in member stiffness or connectivity_ The key procedures consists of 1) partitioning the whole structure into the changed part and the unchanged part, 2) condensing the internal degrees of freedom and forming the unchanged part substructure, 3) assembling and solving the new stiffness matrix from the unchanged part substructure and the changed members.

Analysis of Propagation Characteristics of Acoustic Signal in Insulation Oil (음향신호의 유중 전파특성 분석)

  • Yun, Min-Young;Park, Kyoung-Soo;Wang, Guoming;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.114-119
    • /
    • 2016
  • This paper dealt with the propagation characteristics of acoustic signal in insulation oil for the purpose of improving the reliability of AE (acoustic emission) method used for condition monitoring of oil-immersed transformers. A discharge source was placed in insulation oil and AE sensors ($f_c$ :140 kHz) were attached on the oil tank to study the changes of velocity and propagation path with the depth and distance. The average velocity was 1,436 m/s and the velocity decreased with the increase of depth from the oil surface to 430 mm. The propagation paths were classified into three sections by the shortest reflection path of the detected signal. The minimum distinguishable distance in each section was 70 mm. It was also verified that PD (partial discharge) with a magnitude over than 500 pC can be detected by the AE sensors.

Effect of Oxidation of Ni on the Microstructure of Ni/YSZ Anode and Crack Formation in YSZ Electrolyte Layer for SOFC (Ni의 산화가 고체산화물 연료전지용 Ni/YSZ 연료극의 미세조직과 전해질의 균열에 미치는 영향)

  • Lim, Jun-Sil;Choi, Jong-Joon;Kwon, Oh-Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.805-811
    • /
    • 2006
  • The microstructural changes in Ni/YSZ anode substrate and crack formation during Ni oxidation were investigated. The composition of as-sintered anodes was 56 wt% NiO+44 wt% YSZ and that of electrolyte was 8 mol% yttria. After complete reduction, specimens were oxidized in $N_2$ + air at $600\sim800^{\circ}C$. Oxygen partial pressure was controlled in between 0.05 atm and 0.2 atm $O_2$. When the anode was oxidized, at higher than $690^{\circ}C$, three layers were formed in the specimens. The first was fully oxidized layer(NiO/YSZ), the second was a mixed layer and the third, near-intact layer. Under $640^{\circ}C$ such distinctive layers were not observed. Cracks formed at electrolyte layer when weight gain attained at $65\sim75%$ of the total gain due to complete oxidation despite of different oxidation temperature and oxygen partial pressure.

Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer (광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성)

  • 이상훈;심승환;이광식;김달우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.50-56
    • /
    • 2003
  • It is well known that a partial-discharge(PD) in insulation oil is the source of various physical and chemical phenomena, such as heat, light, gas, chemical transformation, electric current, electromagnetic radiation and ultrasonics. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Ultrasonic-wave detection is a useful method for the diagnosis of the transformer-insulation condition. Conventionally, ulyrasonic waves are detected by Piezo-electric transducer, but we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.