• Title/Summary/Keyword: paper drain

Search Result 612, Processing Time 0.094 seconds

An Evaluation on the Result of Pilot Test for Soft Grounnd Improvement in Asan (아산지역에서의 연약지반개량을 위한 시험시공 결과에 대한 평가)

  • 이재원;김성인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.615-622
    • /
    • 2000
  • This paper is relate to the result of pilot test in Asan. In order to evaluate the characteristics of behavior and deformation in Asan and to analyse the effect of soft ground treatment, preloading, two types of paper drain and pack drain were constructed in the ground. Settlement gauges, pressure meters, pressure cells and ground water gauges were monitored and also borings and piezoncone tests were performed. As a result of analyse, every vertical drained area was consolidated over 90% degree of consolidation but preloaded area was not reached to 90%.

  • PDF

Threshold Voltage Dependence on Bias for FinFET using Analytical Potential Model

  • Jung, Hak-Kee
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.107-111
    • /
    • 2010
  • This paper has presented the dependence of the threshold voltage on back gate bias and drain voltage for FinFET. The FinFET has three gates such as the front gate, side and back gate. Threshold voltage is defined as the front gate bias when drain current is 1 micro ampere as the onset of the turn-on condition. In this paper threshold voltage is investigated into the analytical potential model derived from three dimensional Poisson's equation with the variation of the back gate bias and drain voltage. The threshold voltage of a transistor is one of the key parameters in the design of CMOS circuits. The threshold voltage, which described the degree of short channel effects, has been extensively investigated. As known from the down scaling rules, the threshold voltage has been presented in the case that drain voltage is the 1.0V above, which is set as the maximum supply voltage, and the drain induced barrier lowing(DIBL), drain bias dependent threshold voltage, is obtained using this model.

Geotextiles Horizontal Drain between Earth Fills and Natural Soft Ground (토목섬유를 사용한 무처리 연약지반과 성토사이의 수평배수층)

  • Lee, Hyoung-Kyu;Kong, Kil-Yong;Kim, Hyun-Tae
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.129-138
    • /
    • 2002
  • This paper presents a study on the discharge capacity of geotextiles as a horizontal drain layer placed between the layers of earth fill and natural soft ground. Required discharge capacity of geotextiles as drain layers estimated by consolidation analysis is proportional to the consolidation coefficient of the ground soils and the width of the earth fills. The field discharge capacity of the geotextiles are measured by the hydraulic transmissivity test. And the results show wide variation according to the material characteristics of geotextiles, water content of the soils, vertical pressure, and etc. For the short horizontal drain length, geotextile filter mat can be used for the horizontal drain layer. And f3r the long drain($25{\sim}55m$), it is used for the drain together with Bord Drain.

The Applicability of Numerical Analysis Technique to The Soft Clayey Foundation Improved by Sand Drain (Sand Drain 지반에 대한 변형해석법의 적용성)

  • Lee, Jean-Soo;Lee, Moon-Soo;Jang, Chul
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.1
    • /
    • pp.96-105
    • /
    • 1998
  • Soil properties, drain conditions and numerical analysis technique have great influence upon consolidation behavior. In relevant to the above described fact, this paper aims to examining the applicability of prediction model of consolidation as well as deformation characteristics for soft clayey foundation improved by sand drain. A case study for actual foundation of Kwangyang steel works was performed. Single drain consolidation model proposed by Hansbo and Biot's consolidation theory coupled with modified Cam-clay model developed during the research were employed for the FEM numerical analysis of the foundation. Both smear effect and drain capacity were taken into account for the analysis. Finally the applicability of the newly developed technique to the behavior of foundation composed of soft clay proved satisfactory.

  • PDF

Effects of Size and Shape of Drain on Horizontal Vacuum Drain (배수재의 직경과 형상변화가 수평진공배수에 미치는 영향)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Lee, Byung-Kon
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.293-301
    • /
    • 2001
  • This paper is experimental results of investigating the efficiency of horizontal vacuum drainage system. Effects of size and shape of drain on horizontal vacuum drainage were studied. Model tests in the laboratory with soft marine clay were carried out with drain pipe of having three different diameters and PBD (Plastic Board Drain) of strip shape so that consolidation settlement of soft clay due to applied vacuum pressure, amount of discharge, ground settlement and distributions of pore pressure and undrained shear strength were measured during testing. From results of model test, amount of discharge due to vacuum pressure was increased with the diameter of pipe drain whereas the drain efficiency of pipe in per unit area of drain surface was decreased with diameter of pipe. The rate of discharge per unit time was reduced very fast with diameter of pipe. Settlement of ground surface with time was increased with diameter of pipe as a result of increase of discharge to drain pipe.

  • PDF

Route Selection Protocol based on Energy Drain Rates in Mobile Ad Hoc Networks (무선 Ad Hoc 통신망에서 에너지 소모율(Energy Drain Rate)에 기반한 경로선택 프로토콜)

  • Kim, Dong-Kyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7A
    • /
    • pp.451-466
    • /
    • 2003
  • Untethered nodes in mobile ad-hoc networks strongly depend on the efficient use of their batteries. In this paper, we propose a new metric, the drain rate, to forecast the lifetime of nodes according to current traffic conditions. This metric is combined with the value of the remaining battery capacity to determine which nodes can be part of an active route. We describe new route selection mechanisms for MANET routing protocols, which we call the Minimum Drain Rate (MDR) and the Conditional Minimum Drain Rate (CMDR). MDR extends nodal battery life and the duration of paths, while CMDR also minimizes the total transmission power consumed per packet. Using the ns-2 simulator and the dynamic source routing (DSR) protocol, we compare MDR and CMDR against prior proposals for power-aware routing and show that using the drain rate for power-aware route selection offers superior performance results.

An Amorphous Silicon Local Interconnection (ASLI) CMOS with Self-Aligned Source/Drain and Its Electrical Characteristics

  • Yoon, Yong-Sun;Baek, Kyu-Ha;Park, Jong-Moon;Nam, Kee-Soo
    • ETRI Journal
    • /
    • v.19 no.4
    • /
    • pp.402-413
    • /
    • 1997
  • A CMOS device which has an extended heavily-doped amorphous silicon source/drain layer on the field oxide and an amorphous silicon local interconnection (ASLI) layer in the self-aligned source/drain region has been studied. The ASLI layer has some important roles of the local interconnections from the extended source/drain to the bulk source/drain and the path of the dopant diffusion sources to the bulk. The junction depth and the area of the source/drain can be controlled easily by the ASLI layer thickness. The device in this paper not only has very small area of source/drain junctions, but has very shallow junction depths than those of the conventional CMOS device. An operating speed, however, is enhanced significantly compared with the conventional ones, because the junction capacitance of the source/drain is reduced remarkably due to the very small area of source/drain junctions. For a 71-stage unloaded CMOS ring oscillator, 128 ps/gate has been obtained at power supply voltage of 3.3V. Utilizing this proposed structure, a buried channel PMOS device for the deep submicron regime, known to be difficult to implement, can be fabricated easily.

  • PDF

Utilization of Waste Concrete as Vertical Drain Material (연직배수재료로 폐콘크리트 활용에 관한 기초연구)

  • 이용수;정하익;김우성;권용완
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.571-576
    • /
    • 2001
  • This paper presents the utilization of waste concrete as vertical drain material. The materials used as vertical drain material were the waste concrete, obtained from the demolished apartments or concrete structure and sand. In this study, laboratory model test was performed to investigate settlement and bearing capacity between sand compaction pile and waste concrete compaction pile. The results of laboratory model test showed that the improvement efficiency of soft ground by waste concrete compaction pile was better than sand compaction pile.

  • PDF

Characteristics of Behavior of Brain Board - driven Clay Layers by Vacuum Loading (진공하중에 의한 Drain Board 타입 점토지반의 거동 특성)

  • Lee, Song;Yang, Tae-Seon;Park, Jong-Chan;Paik, Young-Shik
    • Geotechnical Engineering
    • /
    • v.9 no.1
    • /
    • pp.45-58
    • /
    • 1993
  • Paper drain method is one of the methods used for the improvement of soft clay as hydraulic fill sites or the seaside industrial complex. This method adopts a card board as the drain materials instead of sand piles in sand drain method. In this paper 3 types of drain board are used to fond out the characteristics of consolidation by vacuum consolidation model test. So does the no drain board test. This test causes the reduction of pore water pressure to promote the settlement without change of ground water level. Conclusively, the vacuum consolidation shows 3-dimensional behaviors and pore water pressure reaches a negative value in a short time. In addition, it is expected to have a comparatively good consolidation effect using non -woven board, and vacuum loading results in increasing the shear strength at the bottom and top of call layers.

  • PDF

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.