• 제목/요약/키워드: pae

검색결과 781건 처리시간 0.029초

폴리프로필렌/폴리아미드 엘라스토머 블렌드: 모폴로지와 기계적 물성 (Polypropylene/Polyamide Elastomer Blends: Morphology and Mechanical Property)

  • Liu, Qingsheng;Xu, Yan;Zhang, Hongxia;Li, Yuhao;Deng, Bingyao
    • 폴리머
    • /
    • 제38권5호
    • /
    • pp.613-619
    • /
    • 2014
  • The polypropylene/polyamide elastomer (PP/PAE) blends were prepared by melt mixing. PP and PAE in PP/ PAE were immiscible completely. The size of PAE domains was large and the clear gap in the interface between PP and PAE existed, which did not meet the conditions enhancing toughness of polymers by elastomer. Therefore, maleic anhydride grafted polypropylene (MP) was used to improve the miscibility between PP and PAE. The miscibility between PP and PAE was improved and the size of dispersed phase PAE decreased by introducing MP. The crystallization of PP became easier by introducing PAE as a nucleating agent. With the increase of PAE content, the melt-crystallization temperatures of PP components in PP/PAE/MP blends increased gradually. The melt-crystallization of the polytetramethylene oxide segment of PAE component in PP/PAE blends were hampered by PP component. In addition, PAE can enhance significantly the toughness of PP, and the tensile strength and modulus did not decrease.

Polyvinyl Alcohol/Polyamide-epichlorohydrin 복합 지력증강제에 의한 종이 특성 향상 (Enhancement of Paper Characteristics by Polyvinyl Alcohol/Polyamide-epichlorohydrin Coating as a Complex Strength Additive)

  • 장윤재;이활종;강호종
    • 폴리머
    • /
    • 제38권5호
    • /
    • pp.620-625
    • /
    • 2014
  • Polyvinyl alcohol/polyamide-epichlorohydrin(PVA/PAE) 복합 지력증강제 처리에 따른 종이의 건조 및 습윤인장강도와 표면특성 변화를 살펴보았다. PVA/PAE 복합 지력증강제를 사용하는 경우, PVA와 PAE를 각각 첨가제로 사용하는 것에 비하여 건조 및 습윤 인장강도 증가와 함께 치수안정성이 우수해 짐을 알 수 있었으며 이는 PVA와 PAE의 물리적인 가교에 의한 결과로 해석할 수 있었다. PVA/PAE의 복합화는 PAE 지력증강제 처리에 의하여 발생하는 종이의 표면 거칠기의 증가를 최소화하며 동시에 사이징도 증가시켜 종이 인쇄 시 색농도 증가에 기여함을 알 수 있다.

섬유 현탁액내 PAE 고분자 흡착의 열역학적 고찰 (Adsorption Thermodynamics of Polyamidoamide Epichlorohydrin Polymer in an Aqueous Fibrous Suspension)

  • 윤성훈;주광석;이태원;김건한;박병빈
    • 대한화학회지
    • /
    • 제47권3호
    • /
    • pp.220-228
    • /
    • 2003
  • 본 연구는 섬유 교질-현탁액내 PAE 고분자 전해질의 흡착성향과 Lanumuir 및 Freundlich식 흡착 평형에 대한 열역학적 특성을 규명하기 위하여 수행되었다. 섬유의 계면동전위적 특성은 흐름-전기적 방법의 제타전위 측정에 의해 분석되었고, PAE 고분자 흡착량은 고분자 전해질용액의 PCD 적정을 통해 측정되었다. PAE 고분자 내첨은 지료의 제타전위에 크게 영향을 미쳤으며 내첨 초기에는 제타전위 상승 효과가 크게 나타났지만 시간의 경과와 함께 전하 감쇄현상을 나타내었다. PAE 고분자는 저온 또는 상온에서 준-Langmuir 흡착 거동을 보여주었으나 온도가 증가하면서 Freundlich 지수항(v)이 비례적으로 높아지는 결과를 나타내었다. PAE 고분자의 Gibbs 흡착 자유에너지로부터 산출한 트레인 수$(N_{seg})$는 상온에서 약 7~8의 범위로 나타났고 고분자 고리의 노출반경은 약 215 nm로서 $10^{\circ}C$ 온도상승에 대해 점차 9%씩 증가하였다. 지료 내 PAE 고분자의 흡착 엔탈피는 -27~-29 kJ/mol이며 저에너지 물리흡착임이 규명되었다.

PAC-PAE 2중 고분자 내첨 지료의 고분자 흡착 및 교질 분산계의 안정성 연구 (Polymer Adsorption and fiber Dispersion Stability of a Paper Stock Colloidal Suspension with a PAC-PAE Dual Polymer System)

  • 윤성훈;김태영;김덕기;송병규
    • 펄프종이기술
    • /
    • 제35권2호
    • /
    • pp.18-25
    • /
    • 2003
  • The adsorption of co-cationic dual polymer system was investigated as was the fiber dispersion stability of a paper stock suspension. Polyaluminum chloride(PAC) and polyamidoamine epichlorohy-drin(PAE) polymers were used as wet-end additives. The adsorbed amounts of PAE polymer in a wet stock were measured by using polyelectrolytic PCD titration. The sheet forming experiments were carried out in a standard handsheet machine. Fiber dispersion stability and relative retention were evaluated in terms of M/K non-uniformity index and sheet basis weight, respectively. The PAE polymer adsorption of Langmuir-isothermal type decreased with increasing PAC addition level. The combination of the two cationic polymers presumably exerts a site-blocking effect by the low molecular weight PAC which gives a partial charge neutralization at a minimum level of addition. From a thermodynamic view point of PAE adsorption, an increase in adsorption entropy and a decrease in train number suggests that the PAR polymer has an extended conformation structure that potentially leads to an enhancement of the fiber dispersion stability. This conclusion is supported by handsheet experiments that examined the PAC-PAE dual polymer effects on the sheet formation and retention.

검출기 측정방법에 따른 PAE값의 변화 (Change of PAE according to Detector Measurement Method)

  • 임인철
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.307-311
    • /
    • 2010
  • 본 연구는 검출기 측정방법에 따라 관전압 정확도 검사결과인 PAE값이 어떻게 달라지는지 알아보고자 한다. 실험방법으로는 측정거리와 X선관 각도, 방향에 따른 PAE값의 변화실험에서는 초점과 측정기간의 거리를 100cm, 80cm, 60cm에 위치시킨 상태에서 관전압지시치는 70kVp, X선관 각도는 음극, 양극측으로 $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$로 맞추어 측정하고, 관전압지시치에 따른 PAE값의 변화실험에서는 관전압 60kVp, 70kVp, 80kVp, 90kVP, 100kVp를 설정하고 소초점과 대초점을 전환하며 측정하였다. 측정거리와 X선관 각도, 방향에 대한 PAE값의 결과를 보면 100cm일 경우에는 음극측에서 전체적으로 PAE값이 높게 나타났으며 80cm, 60cm일 경우에는 양극측에서 높게 나타났다. PAE값의 변동율은 100cm일 경우 음, 양극측 모두 안정적으로 나타났으며 80cm, 60cm일 경우에는 불균형적으로 나타났다. 관전압지시치에 따른 PAE값의 결과로는 대초점보다는 소초점이 높게 나타났으며, 지시치가 클수록 높게 나타났다. 오차 범위는 지시치가 클수록 적게 나타났다.

패장의 생약학적 연구 (Pharmacognostical Studies on the 'Pae Jang')

  • 박종희;최정규
    • 생약학회지
    • /
    • 제37권4호
    • /
    • pp.302-306
    • /
    • 2006
  • 'Pae Jang (敗醬)' is one of Chinese crude drugs used mainly as a edema, abdominal pain and hemoptysis, etc. With regard to the botanical origin of 'Pae Jang', it has been considered to be Patrinia scabiosaefolia of Valerianaceae, but there has never been studied pharmacognostically. To clarify the botanical origin of the 'Pae Jang', we studied on the anatomical characteristics of the roots of three species growing in Korea. Through our studies, the botanical origin of 'Pae Jang' from Korea was proved to be the under ground portions of Patrinia scabiosaefolia and Patrinia villosa.

The effects of paeoniflorin injection on soluble triggering receptor expressed on myeloid-1 (sTREM-1) levels in severe septic rats

  • Liu, Xiao-Rong;Xu, Jie;Wang, Yi-Min;Ji, Ming-Suo;Liu, Fu-Shan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제20권6호
    • /
    • pp.565-571
    • /
    • 2016
  • Paeoniflorin (PAE) is the most abundant compound in Xuebijing injection widely used to treat sepsis. We aimed to investigate effect of PAE on expression of soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) in a rat model of sepsis. Wistar rats were divided into Normal, Model, and PAE groups (n=20 each). Endotoxin was administrated at 5 mg/ml/kg in Model and PAE rats to establish rat sepsis model. 1 h after endotoxin administration, PAE was administrated at 4 ml/kg in PAE group once per day for 3 days. Routine blood tests and biochemical indexes were assessed, including aspartate aminotransferase (AST) and creatine kinase-MB (CK-MB). The plasma sTREM-1 level was measured using quantitative ELISA. At the end of experiment, the small intestine, liver, kidney and lung were subjected to pathological examinations. A rat model of sepsis-induced multiple organ dysfunction syndrome (MODS) was established successfully with endotoxin administration (5 mg/ml/kg), evidenced by histo-pathological examinations, routine blood tests and biochemical indexes: platelet count decreased and white blood cell count increased (p<0.05), CK-MB and AST increased (p<0.05). PAE treatment significantly reduced the plasma levels of AST, CK-MB, and sTREM-1, compared to Model group (p<0.05). Meanwhile, sepsis-induced damages in the liver, lung, stomach and intestinal mucosa were also markedly ameliorated by PAE treatment. PAE demonstrated a significantly protective effect in a rat model of sepsis by decreasing plasma sTREM-1 level, reducing inflammation, preventing MODS and protecting organ functions.

Evaluating Pharmacological Effects of Two Major Components of Shuangdan Oral Liquid: Role of Danshensu and Paeonol in Diabetic Nephropathy Rat

  • Chen, Ying;Liu, Zhuying;Zhou, Fuxing;Zhao, Hang;Yang, Qian;Li, Hua;Sun, Jiyuan;Wang, Siwang
    • Biomolecules & Therapeutics
    • /
    • 제24권5호
    • /
    • pp.536-542
    • /
    • 2016
  • Shuangdan oral liquid (SDO) containing radix Salviae miltiorrhizae (Chinese name Danshen) and cortex moutan (Chinese name Mudanpi) is a traditional Chinese medicine using for treating vascular diseases. Danshensu (DSS) is a main effective monomer composition derived from radix Salviae miltiorrhizae and paeonol (Pae) from cortex moutan. Although the two herbs are widely used in traditional Chinese medicine, the pharmacological functions of their active compositions were not reported. Therefore, the research of DSS and Pae in mechanisms and pharmacodynamics interaction can provide scientific evidence to support clinical application. The diabetic nephropathy (DN) rats which were induced by streptozotocin (STZ) were treated with SDO, DSS, Pae, and DSS+Pae for eight weeks. The positive effects on DN animal models were investigated by detection of physiological and biochemical indexes and oxidative stress markers, within five treatments: SDO, DSS, Pae, DSS+Pae and insulin group. Compared with the model group, the DSS+Pae group improved the renal function, blood lipid metabolism and blood viscosity, increased the vitality of T-SOD or T-AOC and decreased the level of MDA or NO after the treatment. The study was successfully showed that the DSS+Pae group could delay the process of DN, especially in the renal injury part of histopathology changes. Our results suggest that the co-administration of DSS and Pae significantly may play a protective role in DN rats through decreasing the oxidative stress and improving the blood lipid metabolism mechanisms.

Adhesive Strength in Tension of High Volume PAE-Modified Cement Mortar with High Flowability for Floor Finishing

  • Do, Jeong-Yun;Soh, Yang-Seob
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.739-746
    • /
    • 2003
  • Various researches on the application of polymer dispersions to the cement mortar and concrete have been carried out in many countries like America, Japan and Germany and so on due to their high performance and good modification effect. PAE of polymer dispersion widely used in situ was employed that the high flowability may be induced in the cement mortar. In order to investigate the modification of cement mortar with high flowability by PAE and fracture mode of adhesive strength properties in tension of that, experimental parameters were set as PAE solid-cement ratio(P/C) and cement: fine aggregate(C:F) and the experiments such as unit weight, flow, consistency change, crack resistance and segregation that inform on the general properties have been done. Adhesion in tension is measured with a view to comprehending the properties and fracture mode in tensile load. Consistency change of cement mortar modified by PAE did grow better as the ratio of PAE solid-cement increased and was much superior to that of resin based flooring such as polyurethane and epoxy which recorded the loss of consistency in 90 min. after mixing. Adhesive strength in tension increased with continuity during curing period and showed the maximum in case of C:F=1:1 and P/C=20%.

진단용(診斷用) X선장치(線裝置)의 관전압(管電壓) 백분율(百分率) 평균오차(平均誤差)에 관한 조사(調査) 연구(硏究) (A Study on PAE of Tube Voltage of Diagnostic X-ray Units -At the area of Sungnam, Inchon, Seoul-)

  • 임한영;오현주;김영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.45-50
    • /
    • 1993
  • In this paper, the PAE of tube voltage of 93 diagnostic X-ray units those are using at the 19 general hospitals and 9 local clinics in the area of Sungnam, Inchun, and Seoul have been surveyed. The results are summarized as following. 1. PAE of tube Voltage 70, 100KV at the 56 (60%) X-ray units were ${\pm}7%$ below, at the 8 units (9%), were ${\pm}7%$ above, and those 29 X-ray units (31%) were ${\pm}7%$ below or above with the 70, 100KV tube Voltage in a unit. 2. PAE ${\pm}7%$ below were 68 X-ray units, at the low tube voltage (70KV), and 76 X-ray units at the high tube Voltage (100KV). 3. For six year-use abofe, used X-ray units were PAE ${\pm}7%$ above, and so, the longer used years the more X-ray units became declined in those performance. 4. PAE of tube Voltage were better efficiency at the large capacity 30 X-ray units than small capacity 10. 5. PAE ${\pm}7%$ abovein were only 8 units among 84 diagnostic X-ray units in the general hospitals.

  • PDF