• Title/Summary/Keyword: pH-DO

Search Result 2,208, Processing Time 0.034 seconds

Relationship between Concentration of Phosphorus, Turbidity, and pH in Water and Soil under Aerobic and Anaerobic Conditions (혐기와 호기 상태의 물과 토양에서 pH, PO4-P, 탁도, T-P 농도 관계)

  • Min, Young-Hong;Kang, Sam-Woo;Lee, Hoi-Seon;Chung, Nam-Hyun
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.3
    • /
    • pp.225-229
    • /
    • 2011
  • This research was carried out to elucidate the impacts of dissolved oxygen (DO) concentration to phosphorus release mechanism from soil into water in lakes. $PO_4-P$ contributed to the growth of the total phosphorus (T-P). $PO_4-P$ was steadily increasing because water was accumulating $PO_4-P$. T-P was closely related to turbidity, pH, and DO. We found that DO had decreased because DO was consumed in organic matter decomposition, and that the resulting anaerobic decomposition occurred whenever water had run out of DO. We also found that pH had decreased sharply by production of organic acid by the anaerobic decomposition and that T-P decreased because a decrease in pH removed turbidity by precipitation. T-P was dissolved without microbial decomposition. This mechanism was of great importance in lakes because phosphorus is released from soil into water.

Characterization of Double-layer Optical Sensing Membranes for Dual Sensing of Dissolved Oxygen Concentrations and pH and Their Application to the On-line Monitoring of Fermentation Processes (용존산소농도와 pH의 동시 검출용 이중층 광학 센서막의 특성 및 발효공정의 온라인 모니터링에의 응용)

  • Kim, Chun-Kwang;Lee, Jong-Il
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • A double-layer optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen (DO) and pH value simultaneously. (tris(4,7-diphenyl-1,10-phenanthroline (Rudpp) ruthenium(II)) as a DO sensitive dye has been mixed in the methyl trimethoxy silane (MTMS) sol-gel solution and coated onto one well in a 24-well microtiter plate. On the DO-sensing layer the GA (3-glycidoxypropyl trimethoxy silane (GPTMS), 3-aminopropyl trimethoxy silane (APTMS)) sol-gel solution mixed with 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS) has been coated and used to measure pH values. The double-layer sensing membrane was affected by ionic strength and temperature. The double-layer sensing membrane for DO and pH has been applied to online monitor in microorganism cultivation processes and showed a good performance.

On-line monitoring of microorganism cultivation processes using optical sensing membranes for simultaneous detection of dissolved oxygen and pH (용존산소와 pH의 동시 검출용 광학 센서 막을 이용한 미생물 발효공정의 온라인 모니터링)

  • Kim, Chun-Kwang;Rhee, Jong-II
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.106-112
    • /
    • 2009
  • An optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen(DO) and pH value simultaneously. It has employed HPTS as a pH sensitive dye and a ruthenium(II) complex as a DO sensitive dye. The sensing membrane has been applied to wells in a 24-well microtiter plate. Using the 24-well microtiter plate the concentrations of dissolved oxygen and pH values have been on-line monitored during the cultivations of E.coli DH5${\alpha}$, B.cereus 318 and P.pastoris X-33. On-line monitoring of DO and pH in microorganism cultivation processes showed good performance of the sensing membrane containing 5 mM HPTS and 2 or 5 mg/mL Rudpp.

A study on release characteristics and forms of phosphorus in sediments (퇴적물에서의 인의 용출특성과 존재형태에 관한 연구)

  • 김은호;김형석
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.75-80
    • /
    • 2002
  • This study was carried out to investigate release characteristics of phosphorus with DO, pH and temperature, to suppose its behaviour with time using mathematical model, and to under-stand its forms with pH. Released SRP was in inversely proportional to DO and it did few release in initial aerobic conditions, but it did actively with decreasing DO concentration. Also, its release was increased with increasing pH and temperature. It was found that relation between time and released SRP concentration was zero order reaction. As compared with k values in various pH and temp., they was $k_{15}>k_{25}$ in pH 6 but was $k_{15} in pH 7 and 8. Considering forms of phosphorus with pH, Resdi.-P & NAI-P increased but Ads.-P & Apt.-P decreased with increasing pH.

Effects of pH, Temperature, and Dissolved Oxygen on Phosphorus Release from Marine Sediment to Seawater (해양퇴적물 인 용출에 미치는 pH, 온도, 용존 산소 농도의 영향)

  • Cheon, Hyo-Chang;Nam, Se-Yong;Kim, Sang-Hyoun
    • Journal of Navigation and Port Research
    • /
    • v.36 no.6
    • /
    • pp.513-519
    • /
    • 2012
  • Understanding the behavior of pollutants in the marine environment is essential for coping with the marine pollution problems such as eutrophication. In this study, the effects of environmental parameters on phosphorus release from marine sediment to sea water were investigated. The environmental parameters such as pH in the range of 7 to 9, temperature from 10 to 20C and dissolved oxygen levels (DO) renging 0.7 to 7.0mg/L were examined. Phosphorus release data were taken from batch tests excluding biotic effects, and analyzed using a first-order kinetic model. The effects of environmental parameters were quantified using a statistical methodology. High pH, high temperature, and low DO increased phosphorus release from the sediment to sea water. pH from 7 to 9, temperature from 10 to $20^{\circ}C$, or DO from 7.0 to 0.7 mg/L magnified the equilibrium phosphorus concentration up to 2~3 times.

The effect of the dissolved oxygen concentration on the production of manganese peroxidase by Phaenerochaete chrysosporium

  • Choe, Su-Hyeong;Gu, Man-Bok
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.171-174
    • /
    • 2000
  • The effect of the dissolved oxygen (DO) concentration on the production of manganese peroxidase by Phaenerochaete chrysosporium was studied in the immobilized reactor system. The oxygen levels significantly affected the production of manganese peroxidase (MnP) as well as that of $H_2O_2$. It is known that a high oxygen level is required to produce this enzyme. In this study, however, higher DO concentrations above a critical DO concentration inhibited MnP production. It is thought that a greater $H_2O_2$ production seen with higher DO concentrations caused adverse effects on the MnP production. On the other hand, with lower DO concentrations, $H_2O_2$ did not accumulate enough to stimulate MnP production.

  • PDF

Monitoring of pH and dissolved oxygen in microorganism fermentation processes using a 24-well microplate (24-웰 마이크로 플레이트를 이용한 미생물 발효공정에서 pH 및 용존산소의 모니터링)

  • Kim, Sun-Yong;Kim, Chun-Kwang;Sohn, Ok-Jae;Rhee, Jong-Il
    • KSBB Journal
    • /
    • v.24 no.2
    • /
    • pp.207-211
    • /
    • 2009
  • In this study, the sensing membranes for detection of pH and dissolved oxygen(DO) were prepared by immobilizing 6-aminofluorescein or ruthenium complex onto the sol-gel matrixes of GPTMS, MTMS, and TEOS and then recoated with the mixture of hydrophobic sol-gel and graphite for light insulation. The pH and DO sensing membranes recoated with the light insulation layer showed a higher sensitivity than those without light insulation layer. The sensing membranes were immobilized on the wells of 24-well microplate and used to monitor the fluorescence intensity for pH and DO in E.coli JM109 and P.pastoris X-33 fermentation processes. The change of the fluorescence intensity in the DO sensing membrane agreed with the growth patterns of microorganisms, that the membranes are valuable to monitor the DO in fermentation processes. In the case of pH monitoring, the fluorescence intensity has showed good correlation to the off-line pH data, that the pH membranes are valuable to monitor pH values in fermentations.

Effect of Water Chemistry Factors on Flow Accelerated Corrosion : pH, DO, Hydrazine (유동가속부식에 영향을 미치는 수화학 인자 : pH, 용존산소, 하이드라진)

  • Lee, Eun Hee;Kim, Kyung Mo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.280-287
    • /
    • 2013
  • Flow accelerated corrosion(FAC) of the carbon steel piping in pressurized water reactors(PWRs) has been major issue in nuclear industry. Severe accident at Surry Unit 2 in 1986 initiated the worldwide interest in this area. Major parameters influencing FAC are material composition, microstructure, water chemistry, and hydrodynamics. Qualitative behaviors of FAC have been well understood but quantitative data about FAC have not been published for proprietary reason. In order to minimize the FAC in PWRs, the optimal method is to control water chemistry factors. Chemistry factors influencing FAC such as pH, corrosion potential, and hydrazine contents were reviewed in this paper. FAC rate decreased with pH up to 10 because magnetite solubility decreased with pH. Corrosion potential is generally controlled dissolved oxygen (DO) and hydrazine in secondary water. DO increased corrosion potential. FAC rate decreased with DO by stabilizing magnetite at low DO concentration or by formation of hematite at high DO concentration. Even though hydrazine is generally used to remove DO, hydrazine itself thermally decomposed to ammonia, nitrogen, and hydrogen raising pH. Hydrazine could react with iron and increased FAC rate. Effect of hydrazine on FAC is rather complex and should be careful in FAC analysis. FAC could be managed by adequate combination of pH, corrosion potential, and hydrazine.

Characteristics of Reverse Flux by using Direct Omosis in RO Membrane Process (역삼투막 공정에서 Direct Osmosis의 역방향 Flux 기초특성)

  • Kang, Il-Mo;Dock-Ko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.399-405
    • /
    • 2011
  • In a desalination technology using RO membranes, chemical cleaning makes damage for membrane surface and membrane life be shortened. In this research cleaning technology using direct osmosis (DO) was introduced to apply it under the condition of high pH and high concentration of feed. When the high concentration of feed is injected to the concentrate side after release of operating pressure, then backward flow occurred from treated water toward concentrated for osmotic pressure. This flow reduces fouling on the membrane surface. Namely, flux of DO was monitored under pH 3, 5, 10 and 12 conditions at feed concentrations of NaCl 40,000 mg/L, 120,000 mg/L and 160,000 mg/L. As a result, DO flux in pH 12 increased about 21% than pH 3. DO cleaning was performed under the concentrate NaCl 160,000 mg/L of pH 12 during 20 minutes. Three kinds of synthetic feed water were used as concentrates. They consisted of organic, inorganic and seawater; chemicals of SiO2 (200 mg/L), humic acid (50 mg/L) sodium alginate (50 mg/L) and seawater. As a result, fluxes were recovered to 17% in organic fouling, 15% in inorganic fouling and 14% of seawater fouling after cleaning using DO under the condition of concentrate NaCl 160,000 mg/L of pH 12.

Real-time Control of Biological Animal Wastewater Treatment Process and Stability of Control Parameters (생물학적 축산폐수 처리공정의 자동제어 방법 및 제어 인자의 안정성)

  • Kim, W.Y.;Jung, J.H.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.251-260
    • /
    • 2004
  • The feasibility and stability of ORP, pH(mV) and DO as a real-time control parameter for SBR process were evaluated in this study. During operation, NBP(nitrogen break point) and NKP(nitrate knee point), which reveal the biological and chemical changes of pollutants, were clearly observed on ORP and pH(mV)-time profiles, and those control points were easily detected by tracking the moving slope changes(MSC). However, when balance of aeration rate to loading rate, or to OUR(oxygen uptake rate), was not optimally maintained, either false NBP was occurred on ORP and DO curves before the appearance of real NBP or specific NBP feature was disappeared on ORP curve. Under that condition, however, very distinct NBP was found on pH(mV)-time profile, and stable detection of that point was feasible by tracking MSC. These results might mean that pH(mV) is superior real-time control parameter for aerobic process than ORP and DO. Meanwhile, as a real-time control parameter for anoxic process, ORP was very stable and more useful parameter than others. Based on these results, a stable real-time control of process can be achieved by using the ORP and pH(mv) parameters in combination rather than using separately. A complete removal of pollutants could be always ensured with this real-time control technology, despite the variations of wastewater and operation condition, as well as an optimization of treatment time and capacity could be feasible.