• Title/Summary/Keyword: pH variation

Search Result 1,305, Processing Time 0.221 seconds

Application of AuNPs immobilized on UV Cross-linked P4VP Thin Film as pH Nanosensors (pH 나노센서로의 응용을 위한 UV-가교 P4VP 박막에 고정한 금 나노입자의 특성)

  • Kim, Min-Sung;Jeong, Yeon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1010-1018
    • /
    • 2008
  • In this report, we describe the use of gold nanoparticles (AuNPs) immobilized on pH. responsive, cross-linked poly(4-vinylpyridine) (P4VP) thin films, as a potential application for pH nanosensors. The methodology is based on the variation in surface plasmon resonance of immobilized AuNPs with changing the interparticle distances, caused by the swelling/deswelling of the pH responsive P4VP polymer films. The change in optical properties of the immobilized AuNPs in response to the pH of surrounding media was investigated by a simple yet powerful tool; UV-vis absorption spectroscopy. The swelling of the P4VP chains at pH 2 causes an increase in the interparticle distances of immobilized AUNPS ($\sim20nm$) and hence leads to a blue shift of 48 nm in their surface plasmon resonance band peak. On the other hand, when the surrounding media was altered from pH 2 to 10, a red shift of absorption maxima was observed. The changes were rapid, and the effect was reversible. This system could prove to be useful in fabricating nanosensors for detecting the pH or pH changes of surrounding aqueous medium.

Pasting Behavior of Korean Rice (우리나라 쌀의 호화양상)

  • Kim, Sung-Kon;Chung, Hye-Min;Kim, Sang-Soon
    • Applied Biological Chemistry
    • /
    • v.27 no.2
    • /
    • pp.135-137
    • /
    • 1984
  • Amylograms of 12 traditional (j) and 9 high-yielding $(j{\times}i)$ rice varieties revealed that the high-yielding rice varieties had higher values for peak (P), hot-paste (H) and cold-paste (C) viscosities and showed the less variation among varieties. Peak viscosity had significant negative correlations with C/P and C/H, but no eorrelation with H/P.

  • PDF

Study on Stability Enhancement of P-type ZnO Thin Film Properties (P-형 ZnO 박막 특성 안정성 향상에 대한 연구)

  • Nam, Hyoung-Gin;Cha, Kyung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.472-476
    • /
    • 2007
  • In this study, we investigated methods for p-type ZnO deposition as well as stability enhancement of its properties. The film was prepared by co-depositing AlAs and ZnO in a RF magnetron sputtering system. Property variation was monitored with photoluminescence and Hall measurements by stressing the films at $250^{\circ}C$ for various duration upto 144 hours. Results indicated that co-deposition is a useful method for p-type ZnO preparation. In particular, pre-treatment in 30% $H_2O_2$ for 1min was observed to be effective in reducing the property variation taking place during the subsequent high temperature processes.

  • PDF

Elctrokinetic-Fenton 기법 적용시 토질조건과 오염원의 종류에 따른 과산화수소의 주입특성

  • 김정환;김병일;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.30-33
    • /
    • 2002
  • In this study, feasibility of using hydrogen peroxide as a chemical oxidant for in-situ treatment by EK-Fenton technology were investigated. Kaolinite, kaolinite/sand mixture and illitic soil spiked by phenol and phenanathrene were used and variation of electrochemical characteristics were examined by EK-Fenton test. For kaolinite that having low buffer capacity, hydrogen peroxide was injected effectively from anode reservoir. However illitic soil that having relatively higher buffer capacity had low hydrogen peroxide introducing efficiency. The test results showed that Hydrogen ions generated by current increased during the treatment decreased under pH 3 in the most of kaolinite specimen. Therefore, stabilized hydrogen oxide was injected more effectively in the kaolinite specimen. This study suggests that efficiency of hydrogen peroxide injection by EK-Fenton thechnoloty is dependent of variation of pH in the soil

  • PDF

Development of new cleaning technology using ionized water by electrolysis (전기분해 이온수를 이용한 세정기술 개발)

  • 변문기;백희원;조봉희;김영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.617-620
    • /
    • 1999
  • To reduce the consumption of chemicals and ultra pure water(UPW) in cleaning process used in device manufacturing, we proposed wet processes that use electrolytic ionized water(EIW), which is generated by electrolysis of a diluted electrolyte solution or UPW and systemically investicate the EIW\`s characteristics. EIW\`s pH values are increased in cathode chamber and decreased in anode chamber according to the electrolysis time and its varied ratio is reduced with time increasement. The variation of pH and ORP is increased accordin to the applied voltage until critical voltage. But more than that voltage, the variation is decreased because of ion\`s scattering effect. When electrolyte is added, the effects of electrolysis is increased because electrolyte acts as catalyst. But when the density of electrolyte is increased more than critical value, ion\`s flowage is obstructed and the effects of electrolysis is decreased.

  • PDF

A Study on the Inactivation of Phytophthora Blight Pathogen (Phytophthora capsici) using Plasma Process (플라즈마 공정을 이용한 고추역병균(Phytophthora capsici) 불활성화에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1601-1608
    • /
    • 2014
  • Plasma reactor was used for the inactivation of Phytophthora capsici which is phytophthora blight pathogen in aquiculture. Effects of first voltage, second voltage, air flow rate, pH, incubation water concentration were examined. At the low $1^{st}$ voltage, under 80 V, the lag phase was noticed within 30 sec, however, it was not shown over 100 V. The variation of optimum operation condition was not shown by the variation of microorganisms. However, the inactivation rate was different by the variation of species of microorganisms. The inactivation rate and efficiency were increased by the increase of $2^{nd}$ voltage. The highest initial inactivation rate was shown at pH 3 and the rate was decreased by the increase of pH. The inactivation rate increased by the increase of air flow rate, however, it was shown as similar at the rate of 4 L/min and 5 L/min. The inactivation rate was distinctly decreased at the three times concentration of incubation solution comparing at the distilled water and basic incubation solution.

Distribution of Inorganic Phosphorus Fractions in Sediments of the South Han River over a Rainy Season

  • Vo, Nguyen Xuan Que;Ji, Yoonhwan;Doan, Tuan Van;Kang, Hojeong
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.229-240
    • /
    • 2014
  • Rain events are extremely important for phosphorus (P) dynamics in rivers since large portions of annual river P loads can be transported in particulate forms during only a few major events. Despite their importance, a precise estimation of P contribution in river sediments after rainy seasons has rarely been reported. This study estimated the longitudinal variation in the concentrations of different inorganic P fractions in bed sediments of the South Han River over a rainy season, through using the sequential extraction method. Non-apatite P was the dominant form, representing more than 60% of total inorganic P (TIP) content in sediments. Although no significant variation of TIP contents was observed, the proportion of bioavailable P in TIP pools decreased after the rainy season. The concentrations of individual inorganic P fractions ($NH_4Cl-P$, $NH_4F-P$, NaOH-P, and $H_2SO_4-P$) were significantly different across sites and after the rainy season (p < 0.05, two-way ANOVA). $NH_4F-P$ and NaOH-P concentrations in sediments increased in a downstream direction. After the rainy season, $NH_4Cl-P$ concentrations in sediments decreased whereas $NH_4F-P$ and $H_2SO_4-P$ concentrations increased. The redistribution of individual P fractions in sediments observed after rainy seasons were possibly due to the changing contribution of various sources of runoff and the variation in flow related particle size. Current estimation of P in bed sediments of the South Han River suggests a lower potential of internal P loading from sediments after the rainy season.

Effect of Interillage and Muddying by Free-Ranging Ducks on pH and Dissolved Oxygen of Stagnant Water, and Soil Physicochemical Properties in Paddy field Soil (논 방사오리에 의한 중경탁수가 관개수의 pH, 용존산소농도 및 토양 이화학적 성질에 미치는 영향)

  • 고병대
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.3
    • /
    • pp.262-266
    • /
    • 2003
  • The present study was carried out to investigate the relationships among intertillage and muddying by free-ranging ducks (Chinese native ducks) and pH, dissolved oxygen of irrigation water, and physicochemical properties of soil. Two paddy fields comprised of the muddying (muddy water without physical stimulation to a rice plant by the ducks) and the control plots (no ducks) were used for this study. As a muddying plot, 50 hills were randomly selected and each hill was fenced with a wire net in order to prevent from stimulating physically by the ducks. The variation in irrigation pH was smaller in the muddying plot than the control plot, and the pH was around 7.4. Dissolved oxygen was significantly higher (P<0.01) in the muddying plot than the control plot during the first half period after the ducks were introduced. Then it decreased rapidly as the rice plants grew in all plots. The contents of the suspended soil and turbidity in irrigation water were not changed over the free-ranging period, but $\textrm{NH}_3\textrm{-N}$ and $\textrm{P}_2\textrm{O}_5$ were decreased by intertillage and muddying by the ducks. There were no differences in both the soil physics and chemistry between the muddying plot and the control plot during and after finishing of the free-ranging period. These results indicate that intertillage and muddying by the ducks resulted in a small variation in stagnant water pH, and reduced the dissolved oxygen and $\textrm{P}_2\textrm{O}_5$, although the physiochemical properties of soil were not changed.

Application of Iron Sand as Adsorbent for the Removal of Heavy Metal (중금속 제거용 흡착제로서의 철광사 적용)

  • Yang, Jae-Kyu;Yu, Mok-Ryun;Lee, Seung-Mok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1180-1185
    • /
    • 2005
  • Iron sand, having iron as a major component, was applied in the treatment of synthetic wastewater containing Cu(II) or Pb(II). To investigate the stability of iron sand at acidic condition, dissolution of Fe and Al was studied with variation of solution pH ranging from 2 to 4.5. Iron concentration in the extracted solution was below the emission regulation of wastewater even at a strong acidic condition, pH 2. Although an important concentration of aluminum was extracted at pH 2, the dissolution greatly decreased above pH 3. This stability test suggests that application of iron sand has little problem in the treatment of wastewater above pH 3. Adsorption capacity of Cu(II) and Pb(II) onto iron sand was investigated in a batch and a column test. In case of Cu(II), rapid adsorption was noted, showing 50% removal within 2 hrs, and then reached a near complete equilibrium after 24 hrs. Adsorption was favorable at higher pH in each metal ion and showed a near complete removal above pH 6, indicating a typical cationic-type adsorption. From the adsorption isotherm obtained with variation of the concentration of each metal ion, the maximum adsorption capacity of Cu(II) and Pb(II) was identified as 2,170 mg/kg 및 3,450 mg/kg, respectively.

Impact of pH on the response of bovine serum albumin to gold surface plasmon resonance chip (소 혈청 알부민의 금 표면 플라즈몬 공명 칩과의 반응에 대한 pH의 영향)

  • Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.326-330
    • /
    • 2021
  • Reactions between gold (Au) surface plasmon resonance (SPR) chips and bovine serum albumin (BSA) dissolved in solutions of different pH were investigated. The charge on the BSA depends on the pH of the solution in which it is dissolved. Thus, dissolving BSA in different pH solutions resulted in different charges of BSA. Among the BSA dissolved in solutions with pH 4.01, 7.4, and 10.01, the SPR response was the highest for BSA dissolved in the solution of pH 4.01. To eliminate the response variation owing to the difference in the refractive indices of the solutions, phosphate buffered saline (PBS) was injected into the system after the reaction of BSA with the Au SPR chip had happened. In this case too, the BSA dissolved in the solution with pH 4.01 exhibited the highest response. This may be attributed to the non-uniform distribution of ionic patches on the BSA, which can induce electrostatic attraction to the surface even though BSA has a positive charge at pH 4.01, and the absolute values of the net charge of BSA at pH 4.01 and 7.4 were very close.