• Title/Summary/Keyword: pCR

Search Result 1,873, Processing Time 0.024 seconds

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

Determination of Cr(Ⅲ) Iron by Chemiluminescence Method (화학발광법을 이용한 Cr(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Ju, Ik Su
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.2
    • /
    • pp.145-150
    • /
    • 2002
  • A Method to determine Cr(III)ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Cr(III) to a solution of lucigenin a nd hyrogen peroxide. The effects of pH, injection volumes of reagent and sample, and concentration of lucigenin and hyrogen peroxide on the chemiluminescence intensity have been investigated. The calibration curve for Cr(III) ion was linear over the range from 1.0${\times}$$10^{-6}$ to 1.0${\times}$$10^{-3}$M and the detection limit was 5.2${\times}$$10^{-8}$M under the optimal experimental condition of 437nm, 12.8,and 1.0${\times}$$10^{-6}$ and 2.0M for emission wavelength, pH, and concentration of lucigenin and hyrogen peroxide, respectively.

A Study on Coagulation and Ozone Treatment of Nonbiodegradable Substances in Landfill Leachate (생물학적 난분해성물질을 함유한 매립장 침출수의 응집 및 오존처리에 관한 연구)

  • Kim, Jong Shik;Choi, Joon Ho
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.330-335
    • /
    • 1998
  • The objectives of this study are summarized with two. The one is to remove of $COD_{Cr}$, color and turbidity with coagulation and ozonation in nonbiodegradable landfill leachate, the other is to compare of water qualities with pre-ozonation and post-ozonation. The results are summarized as follows ; 1) 90 minutes ozonation with $75mgO_3/min$($4.5gO_3/hr$) was conducted at pH 4,7, 10 to remove $COD_{Cr}$. Removal efficiencies were investigated with 48.2%, 52.6%, and 62.3% respectively. As increasing pH, $COD_{Cr}$ removal efficiencies were increased, it was considered that hydroxyl radical($OH{\cdot}$) which strongly oxdize and nonselectively react with organic compounds, was rapidly produced by ozone self-decomposition at high pH. 2) Alum, ferric chloride and ferrous sulfate were used for coagulation as inorganic coagulant. Ferric chloride was investigated with optimal coagulant, and it removed $COD_{Cr}$ about 12.0% at pH5 and dosage of $2,000m{\ell}/{\ell}$. Cation(C-101P), anion(A-601P) and nonion(SC-050) were tested to remove organic pollutants in landfill leachate. Cation(C-101P) was investigated with the most effective organic coagulant, and removal efficiency of $COD_{Cr}$ was 19.8% at pH5 and dosage of $100m{\ell}/{\ell}$. 3) Color and turbidity were removed up to 88.6%, 97.0% at pH10, when contacted 90 minutes with ozone, respectively. These removal efficiencies were much higher than those of $COD_{Cr}$ and $COD_{Mn}$. It was considered that ozone could oxdize the triggering materials of color and turbidity selectively and preferentially. 4) $COD_{Cr}$, color and turbidity were more effectively removed with pre-ozonation than post-ozonation about 8%, 3.5% and 1% respectively. These results were well corresponed with other's studies that pre-ozonation will increase the effect of coagulation.

  • PDF

Effect of Chromium Methionine Supplementation on Obesity Index and Serum Lipids in Rats (Chromium Methionine첨가가 비만지수 및 지질 대사에 미치는 영향)

  • Kim, Hyun-Sook;Lee, Sun-Yeon;Kim, Chang-Hyeuk;Ohh, Sang-Jip;Shin, Jong-Seo;Sung, Kyung-Il
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.5
    • /
    • pp.706-709
    • /
    • 2003
  • Chromium (Cr) plays an important role in body composition. Several human and animal studies of Cr supplementation have reported increases in lean body mass, often with concurrent decreases in body fat. The purpose of the current study was to determine the effects of supplemental Cr as chromium methionine (CrMet) on obesity index, body fat and serum lipids in rats. Thirty-six male Sprague-Dawley rats were divided into four groups of nine rats. Rats received a AIN-76 semipetrified basal diet or high fat diet supplemented with 300 ppb CrCl$_3$and CrMet as well as no added dietary Cr (referred to as Control, HF, HFCr, and HFCrMet). After 6 weeks on the respective diets, animals were killed and analyzed for differences in serum lipid concentrations. Rats supplemented with CrMet had a slightly higher naso-anal length and final body weight was decreased. The lowest obesity index and body fat content were found in CrMet supplemented animals (p〈0,05). Supplemental CrMet decreased the total lipid, triglyceride and total cholesterol. The significant differences observed were total cholesterol concentration for CrMet supplementation. These indicate that supplemental Cr, as chromium methionine, resulted in a significant decrease of obesity index and body fat and influence serum lipid concentrations, possibly by decreasing the body fat.

Estimation of Glomerular Filtration Rate using Chromium-51 EDTA (Cr-51 EDTA GFR 검사 결과의 분석 및 의의)

  • Lim, Soo-Yeon;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.98-103
    • /
    • 2009
  • Purpose: Correct estimation of Glomerular filtration rate (GFR) is very important for an accurate clinical assessment of the kidney function. This study compares four GFR markers, a serum creatinine-based estimation using MDRD formula, Cystatin-C, Cr-51 EDTA 2 samples and 6 samples. Materials and Methods: Serum creatinine concentrations, Cystatin-C serum concentrations and Cr-51 EDTA clearance are measured in 43 patients who received or donated kidney. Results: The correlation coefficient between serum based estimated GFR (MDRD) and Cr-51 EDTA 6 samples was 0.817 (p<0.01). The correlation coefficient between Cystatin-C based GFR and EDTA 6 samples was 0.7322 (p<0.01). Regression analysis showed a statistically significant correlation between Cr-51 EDTA 2 samples and 6 samples (r=0.971, p<0.01). Mean value and ${\pm}2SD$ for the difference between Cr-51 EDTA 2 samples and 6 samples were 4.7 mL/min and ${\pm}9.3$ respectively. Conclusions: The estimation of two samples Cr-51 EDTA showed that the method can be simplified by reducing blood samples without losing its high accuracy.

  • PDF

Effect of Organic Acids on Cr(III) Oxidation by Mn-oxide

  • Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • v.41 no.4
    • /
    • pp.241-245
    • /
    • 1998
  • Two oxidation states of chromium commonly occur in natural soil/water systems, Cr(III) and Cr(VI). The oxidized form, Cr(VI), exists as the chromate ion and is more mobile and toxic than Cr(III). Therefore oxidation of Cr(III) by various Mn-oxides in natural systems is a very important environmental concern. Organic substances can inhibit the Cr(III) oxidation by binding, Cr(III) strongly and also by dissolving Mn-oxides. Most of Cr(III) oxidation studies were carried out using in vitro systems without organic substances which exist in natural soil/water systems. In this study effect of organic acids - oxalate and pyruvate - on Cr(III) oxidation by $birnessite({\delta}-MnO_2)$ was examined. The two organic acids significantly inhibited Cr(III) oxidation by birnessite. Oxalate showed more significant inhibition than pyruvate. As solution pH was lowered in the range of 3.0 to 5.0, the Cr(III) oxidation was more strongly depressed. Addition of more organic acids reduced the Cr(III) oxidation mare extensively. Different inhibition effects by the organic acids could be due to their ability of reductive dissolution of Mn-oxides and/or Cr(III) binding. Organic acids dissolved Mn-oxide during the Cr(III) oxidation by the oxide, Dissolution by oxalic acid was much greater than that by pyruvate, and the dissolution was more extensive at lower pH. Inhibition of Cr(III) oxidation was parallel to the dissolution of Mn-oxide by organic acids. Although the effect of Cr(III) binding by organic acids on Cr(III) oxidation is not known yet, Mn-oxide dissolution by organic acids could be a main reason for the inhibition of Cr(III) oxidation by Mn-oxide in presence of organic acids. Thus oxidation of Cr(III) to Cr(VI) by various Mn-oxides in natural systems could be much less than the oxidation estimated by in vitro studies with only Cr(III) and Mn-oxides.

  • PDF

Effects of Organic Matter and pH on Chromium Oxidation Potential of Soil

  • Chung, Jong-Bae;Eum, Jin-Sup
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.5
    • /
    • pp.346-351
    • /
    • 2001
  • Oxidation of Cr(III) to Cr(VI) can increase availability and toxicity of chromium. In this study, possible mechanisms by which pH and organic matter can control the chromium oxidation and reduction in soil system were examined using four soils of different pHs and organic matter contents. Reduction of Mn-oxides occurred in the soils of higher organic matter content (4.0%), but Mn-oxide was quite stable during the incubation in the soil of pH 7.0 and 0.5% organic matter content. Manganese oxides can be reductively dissolved at lower pH and higher organic matter conditions. The soil of pH 7.0 and 4.0% organic matter content showed the highest Cr-oxidation potential. Reduction of soluble Cr(VI) was observed in all the soils examined. The most rapid reduction was found in soil of pH 5.5 and 4.0% organic matter content, but the reduction was slow in soil of pH 7.0 and 0.5% organic matter content. Thus, the reductive capacity of organic matter added soils was much higher as compared to other two soils of lower organic matter content. In all the soils examined, the reductive capacity of soluble chromium was much higher than the oxidative capacity. Organic matter was found to be the most important controlling factor in the chromium oxidation and reduction. Reduction of Cr(VI) to Cr(III) could be a potentially useful remediation or detoxification process, and availability and toxicity of chromium in soil would be controlled by controlling organic matter content and pH of the soils.

  • PDF

Morphology Control of NiO Catalysts on NiCrAl Alloy Foam Using a Hydrothermal Method (수열합성법을 이용한 NiCrAl 합금 폼 위에 합성된 NiO 촉매 형상 제어)

  • Sin, Dong-Yo;Lee, Eun-Hwan;Park, Man-Ho;Ahn, Hyo-Jin
    • Korean Journal of Materials Research
    • /
    • v.26 no.7
    • /
    • pp.393-399
    • /
    • 2016
  • Flower-like nickel oxide (NiO) catalysts were coated on NiCrAl alloy foam using a hydrothermal method. The structural, morphological, and chemical bonding properties of the NiO catalysts coated on the NiCrAl alloy foam were investigated by field-emission scanning electron microscopy, scanning electron microscopy-energy dispersive spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, respectively. To obtain flower-like morphology of NiO catalysts on the NiCrAl alloy foam, we prepared three different levels of pH of the hydrothermal solution: pH-7.0, pH-10.0, and pH-11.5. The NiO morphology of the pH-7.0 and pH-10.0 samples exhibited a large size plate owing to the slow reaction of the hydroxide ($OH^-$) and nickel ions ($Ni^+$) in lower pH than pH-11.5. Flower-like NiO catalysts (${\sim}4.7{\mu}m-6.6{\mu}m$) were formed owing to the fast reaction of $OH^-$ and $Ni^{2+}$ by increased $OH^-$ concentration at high pH. Thus, the flower-like morphology of NiO catalysts on NiCrAl alloy foam depends strongly on the pH of the hydrothermal solution.