• Title/Summary/Keyword: pCR

Search Result 1,869, Processing Time 0.028 seconds

Characteristics of Stabilization and Adsorption of Heavy Metal (As3+, Cr6+) by Modified Activated Carbon (표면 개질 활성탄에 의한 중금속(As3+, Cr6+) 흡착 및 안정화 특성)

  • Shin, Woo-Seok;Na, Kyu-Ri;Kim, Young-Kee
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.185-192
    • /
    • 2015
  • In this study, the adsorption efficiency of mixed heavy metals in aqueous solution was investigated using modified activated carbon. Moreover, the heavy-metal stabilization treatment of contaminated marine sediment was achieved using modified activated carbon as stabilizing agents. From the experimental results, it was shown that the adsorption equilibrium was attained after 120 mins. Heavy metal adsorption was characterized using Freundlich and Langmuir equations. The equilibrium adsorption data were fitted well to the Langmuir model in modified activated carbon. The adsorption uptake of $As^{3+}$ (28.47 mg/g) was higher than $Cr^{6+}$ (13.28 mg/g). In case of the $Cr^{6+}$, the results showed that adsorption uptake decreased with increasing pH from 6 to 10. However, adsorption of $As^{3+}$ slightly increased in the increasing change of pH. The modified activated carbon was applied for a wet-curing duration of 120 days. From the sequential extraction results, the exchangeable, carbonate, and oxides fractions of Cr and As in sediment decreased by 5.8% and 7.6%, respectively.

Applicability Assessment of Acid Treated Red Mud as Adsorbent Material for Removal of Six-valent Chromium from Seawater (해수에서 6가 크롬 제거를 위한 흡착제로서의 산처리 적니 적용성 검토)

  • Kang, Ku;Um, Byung-Hwan;Kim, Young-Kee;Park, Seong-Jik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.5
    • /
    • pp.17-23
    • /
    • 2013
  • Six-valent chromium ($Cr^{6+}$) is a highly toxic pollutant, supplied in a variety of industrial activities such as leather tanning, cooling tower blowdown, and plating. Herein, we investigated the removal of $Cr^{6+}$ from aqueous phase using low-cost adsorbents. Steel slag, montmorillonite, illite, kaolinite, red mud, and acid treated red mud with 0.5, 1.0, and 2.0 M HCl were used as adsorbent for the removal of $Cr^{6+}$ and the results showed that acid treated red mud with 2.0 M HCl (ATRM-2.0 M) had higher adsorption capacity of $Cr^{6+}$ than other adsorbents used. Accordingly, $Cr^{6+}$ removal by ATRM-2.0 M were studied in a batch system with respect to changes in initial concentration of $Cr^{6+}$, initial solution pH, adsorbent dose, adsorbent mixture, and seawater. Equilibrium sorption data were described well by Freundlich isotherm model. The influence of initial solution pH on $Cr^{6+}$ adsorption was insignificant. The use of the ATRM-2.0 M alone was more effective than mixing it with other adsorbents including red mud, zeolite, oyster shell, lime stone, and montmorillonite for the removal of $Cr^{6+}$. The $Cr^{6+}$ removal of the ATRM-2.0 M was slightly less in seawater than deionized water, resulting from the presence of anions in seawater competing for the favorable adsorption site on the surface of ATRM-2.0 M. It was concluded that the ATRM-2.0 M can be used as a potential adsorbent for the removal of $Cr^{6+}$ from the aqueous solutions.

Determination of Chromium (Ⅵ) by Extraction Polarographic Method (추출폴라로그래프법에 의한 Cr (Ⅵ) 의 정량)

  • Park Doo Won;Bae Zun Ung
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.494-499
    • /
    • 1976
  • The extraction-polarographic method applied to the determination of micro amount of chromium (Ⅵ). Chromium(Ⅵ) was extracted into methylisobuthylketone(MIBK) layer containing diethyldithiocarbamate(DDTC) as Cr(Ⅲ)-DDTC complex from acetate buffered aqueous, solution of pH 5.4 and the direct current polarogram for the extract was recorded after addition of sodium perchlorate as supporting electrolyte. The reduction current was diffusion controlled. And the half wave potential of this reduction wave was -0.81 volt vs. SCE. The diffusion current was proportional to the chromium concentraticn in aqueous solution in the range of 8∼160 ppm. And the chromium(Ⅵ) could be selectively determined in the presence of chromium(Ⅲ), since the chromium(Ⅲ) did not interfere up to twice the amount of chromium(Ⅵ). Many of other metals such as Mn(Ⅱ), Cu(Ⅲ), Zn(Ⅱ), Mg(Ⅱ), Ni(Ⅱ) and Ag(Ⅰ) were found to have no effect even when present in 1000 times the amount of chromium (Ⅵ).

  • PDF

Studies on the Concentrations of Cd, Pb, Hg and Cr in Dog Serum in Korea

  • Park, S.H.;Lee, M.H.;Kim, S.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.11
    • /
    • pp.1623-1627
    • /
    • 2005
  • Heavy metal pollution has become a serious health concern in recent years. Dogs are a very good indicator of the pollution load on the environment. They share people's environment and are exposed to the action of the same pollutants. This study estimated the heavy metal contents in the serum of dogs in domestic districts, and assessed the age, sex, feeding habits, living area, breeding environment and smoking habit of the owners. The findings suggest that dogs can be used to monitor the environmental quality of heavy metals. The mean concentrations of heavy metals in the dog serum from 204 samples (108 male and 96 female) were 0.22${\pm}$0.01 $\mu$g/ml, 0.24${\pm}$0.04 $\mu$g/ml, 0.61${\pm}$0.08 $\mu$g/ml, and 0.50${\pm}$0.06 $\mu$g/ml (for Cd, Hg, Pb, and Cr), respectively. Concentrations of Pb, Cd, Hg, and Cr in the dog serum were higher in Yeongnam including Ulsan, and Seoul higher than those of Chungchong and Honam, especially Pb concentration, which was significantly higher (p<0.01). Concentrations of Cd, Hg, Pb, and Cr in serum, were increased by age (p<0.05). When commercial pet food was provided to dogs, Cd and Cr concentrations were significantly higher in dog serum than dogs fed a human diet (p<0.01 in Cd and p<0.05 in Cr). Heavy metal concentrations of dogs owned by smoking owners, were higher than non-smoking owners although there was no significant difference.

Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements (가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성)

  • 황택성;이선아;황계순
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.765-773
    • /
    • 2001
  • In In order to remove harmful trace elements such as $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$ from water, we synthesized AN-co-(MMA/IA) according to various mole ratio of monomers and spun by wet-spinning. And multi-functional PAN ion exchangers were prepared by hydrolysis. We observed structure, degree of functionalization, ion exchange capacity, distribution coefficient and mechanical properties for ion exchanger. Anion exchange capacity decreased in 4.5 ~ 4.2 meq/g with increasing of IA content and cation exchange capacity increased in 1.8 ~ 2.2 meq/g. Tensile strength of the ion exchanger increased up to 0.008 mol% IA content and appeared maximum value by 216$kg/cm^2$Distribution coefficient for AN-co-(MMA/IA) ion exchanger appeared maximum value for Co(II), Ni(II) in pH 5-6 range and for Cr(III) in pH 3-4 range. And the adsorption capacity was in the order of Cr(III) > Co(II) > Ni(II) for multicomponent in continuous process.

  • PDF

Effects of Florfenicol and Chromium (III) on Humoral Immune Response in Chicks

  • Cao, Jiyue;Li, Kui;Lu, Xiaocong;Zhao, Yaxin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.3
    • /
    • pp.366-370
    • /
    • 2004
  • One hundred and sixty day-old Hainan chicks were randomly allotted into eight pens to investigate the effect of different dietary concentrations of chromium (Cr) in the form of chromium chloride, and different dosages of florfenicol on humoral immune responses by determining antibody titers to Newcastle disease (ND) vaccines using the hemagglutination inhibition test. The results indicated that ND antibody titers were significantly higher in chicks receiving Cr at low (5 mg/kg feed) and middle (10 mg/kg feed) dose compared with the control (p<0.01). However, ND antibody titers were significantly decreased in chicks receiving Cr at a high dosage of 500 mg/kg feed (p<0.01), though the ND antibody titers of the early days (d 21 and d 28 of age) were higher than that of the control group. It is suggested that excessive Cr intake has detrimental effects on ND antibody production in chicks. No significantly lower response was measured in chicks that received florfenicol at a low dosage of 50 mg/kg feed (p>0.05), but the ND antibody titers were significantly decreased in chicks receiving 200 and 400 mg/kg feed of the drug (p<0.01). The ND antibody titers of group receiving 200 mg/kg feed of florfenicol plus 10 mg/kg Cr were slightly higher than that of the group receiving single florfenicol of 200 mg/kg although, no significant differences were observed between these two treatments. It is suggested that the humoral immune response impaired by florfenicol (200 mg/kg feed) could not be significantly reversed by Cr (10 mg/kg feed).

Complete Versus Culprit-Only Revascularization for ST-Segment Elevation Myocardial Infarction and Multivessel Disease in the 2nd Generation Drug-Eluting Stent Era: Data from the INTERSTELLAR Registry

  • Kwon, Sung Woo;Park, Sang-Don;Moon, Jeonggeun;Oh, Pyung Chun;Jang, Ho-Jun;Park, Hyun Woo;Kim, Tae-Hoon;Lee, Kyounghoon;Suh, Jon;Kang, WoongChol
    • Korean Circulation Journal
    • /
    • v.48 no.11
    • /
    • pp.989-999
    • /
    • 2018
  • Background and Objectives: We aimed to compare outcomes of complete revascularization (CR) versus culprit-only revascularization for ST-segment elevation myocardial infarction (STEMI) and multivessel disease (MVD) in the $2^{nd}$ generation drug-eluting stent (DES) era. Methods: From 2009 to 2014, patients with STEMI and MVD, who underwent primary percutaneous coronary intervention (PCI) using a $2^{nd}$ generation DES for culprit lesions were enrolled. CR was defined as PCI for a non-infarct-related artery during the index admission. Major adverse cardiovascular event (MACE) was defined as cardiovascular (CV) death, non-fatal myocardial infarction, target lesion revascularization, or heart failure during the follow-up year. Results: In total, 705 MVD patients were suitable for the analysis, of whom 286 (41%) underwent culprit-only PCI and 419 (59%) underwent CR during the index admission. The incidence of MACE was 11.5% in the CR group versus 18.5% in the culprit-only group (hazard ratio [HR], 0.56; 95% confidence interval [CI], 0.37-0.86; p<0.01; adjusted HR, 0.64; 95% CI, 0.40-0.99; p=0.04). The CR group revealed a significantly lower incidence of CV death (7.2% vs. 12.9%; HR, 0.51; 95% CI, 0.31-0.86; p=0.01 and adjusted HR, 0.57; 95% CI; 0.32-0.97; p=0.03, respectively). Conclusions: CR was associated with better outcomes including reductions in MACE and CV death at 1 year of follow-up compared with culprit-only PCI in the $2^{nd}$ generation DES era.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

Variation in adhesion of Streptococcus mutans and Porphyromonas gingivalis in saliva-derived biofilms on raw materials of orthodontic brackets

  • Park, So-Hyun;Kim, Kyungsun;Cho, Soha;Chung, Dong-Hwa;Ahn, Sug-Joon
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.278-286
    • /
    • 2022
  • Objective: To evaluate differences in the adhesion levels of the most common oral pathogens, Streptococcus mutans and Porphyromonas gingivalis, in human saliva-derived microcosm biofilms with respect to time and raw materials of orthodontic brackets. Methods: The samples were classified into three groups of bracket materials: 1) monocrystalline alumina ceramic (CR), 2) stainless steel metal (SS), and 3) polycarbonate plastic (PL), and a hydroxyapatite (HA) group was used to mimic the enamel surface. Saliva was collected from a healthy donor, and saliva-derived biofilms were grown on each sample. A real-time polymerase chain reaction was performed to quantitatively evaluate differences in the attachment levels of total bacteria, S. mutans and P. gingivalis at days 1 and 4. Results: Adhesion of S. mutans and P. gingivalis to CR and HA was higher than the other bracket materials (SS = PL < CR = HA). Total bacteria demonstrated higher adhesion to HA than to bracket materials, but no significant differences in adhesion were observed among the bracket materials (CR = SS = PL < HA). From days 1 to 4, the adhesion of P. gingivalis decreased, while that of S. mutans and total bacteria increased, regardless of material type. Conclusions: The higher adhesion of oral pathogens, such as S. mutans and P. gingivalis to CR suggests that the use of CR brackets possibly facilitates gingival inflammation and enamel decalcification during orthodontic treatment.