• Title/Summary/Keyword: ozone trend

Search Result 61, Processing Time 0.023 seconds

Meteorologically Adjusted Ozone Trends in the Seoul and Susan Metropolitan Areas (서울과 부산지역 기상의 영향을 제거한 오존농도 추세)

  • 김유근;오인보;황미경
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.561-568
    • /
    • 2003
  • Surface ozone concentrations are highly sensitive to meteorological variability. Therefore, in order to reveal the long-term changes in ozone due to the changes in precursor emissions, we need to remove the effects of meteorological fluctuations on the annual distribution of surface ozone. In this paper, the meteorologically adjusted trends of daily maximum surface ozone concentrations in two major Korean cities (Seoul and Busan) are investigated based on ozone data from 11 (Seoul) and 6 (Busan) sites over the period 1992 ∼ 2000. The original time series consisting of the logarithm of daily maximum ozone concentrations are splitted into long-term, seasonal and short-term component using Kolmogorov-Zurbenko (KZ) filter. Meteorological effects are removed from filtered ozone series using multiple linear regression based on meteorologcial variables. The long-term evolution of ozone forming capability due to changes in precursor emission can be obtained applying the KZ filter to the residuals of the regression. The results indicated that meteorologically adjusted long-term daily maximum ozone concentrations had a significant upward trend (Seoul: + 3.02% yr$^{-1}$ , Busan: + 3.45% yr$^{-1}$ ). These changes of meteorologically adjusted ozone concentrations represent the effects of changing background ozone concentrations as well as the more localized changes in emissions.

Discharge Area Characteristics of Ozonizer with $Al_2O_3$ Dielectric ($Al_2O_3$ 세라믹 유전체 오존발생기의 방전면적 특성)

  • Park, Hyun-Mi;Song, Hyun-Jig;Lee, Sang-Gun;Lim, Chang-Ho;Yoon, Bung-Han;Kim, Jong-Hyun;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2214-2216
    • /
    • 2005
  • This paper is researched discharge and ozone generation characteristics of ozonizer using $Al_2O_3$ Ceramic dielectric. The discharge characteristics with variation of the discharge electrode area is studied. The characteristics of ozone concentration. ozone generation and ozone yield were measured to discharge power, discharge electrode area and supplied gas flux for oxygen and air. The solubility of ozone for water concentrations and ozone generations proportional to discharge power and discharge electrode area. Ozone yield has slowly increase with Increasing discharge power at high flow-rate. As the result, the maximum values of ozone characteristics ozone generation and ozone yield, can be obtained 5817[ppm] and 36[g/kWh]. We make enough the ozone concentration as the air in the home. An electric discharge electrode area is apt to shrink gradually into a miniaturization trend of the ozonizer but the enlargement of the occurrence flight of the electric discharge area gives the characteristic enhance the aid in the identity condition through the structure improvement.

  • PDF

Trend Analysis for Stratospheric Ozone Concentration in the Middle Latitude Northern Hemisphere Using HALOE Data (HALOE 자료를 이용한 중위도 지역의 오존농도 추이분석)

  • Ka, Soo-Hyun;Kwon, Mi-Ra;Oh, Jung-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.413-422
    • /
    • 2005
  • The ozone concentration measured by HALOE (Ver 19) from Oct. 1991 to Dec. 2003 is used for analyzing the variation of ozone concentration. The HALOE loaded in UARS is observing several gases in the atmosphere, from 10km to 80km. Fourier analysis of these data in the middle latitude northern hemisphere is reported in this paper. To detect any possible long term trends, the fourier transformed time series was back transformed after removing signals with time periods of less than 6 months. Although the results clearly show the strong annual cycle, it is difficult to show any long term trends from the fourier series. We also compared the ozone volume mixing ratio's from HALOE with that from the ground-based radiometry to evaluate the accuracy of microwave observation at Sookmyung Women's University.

Comparison of Household Trihalomethanes (THMs) Exposure Associated with Use of Municipal Tap Water Treated with Chlorine or Ozone-Chlorine (염소살균과 오존-염소살균 수도수의 사용과 관련한 가정 트리할로메탄 노출 비교평가)

  • Jo, Wan Geun;Gwon, Gi Dong;Dong, Jong In;Jeong, Yong
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.627-635
    • /
    • 2004
  • Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.

Temporal and Spatial Variability of the TOMS Total Ozone; Global Trends and Profiles (TOMS 오존전량의 시공간 변동; 전구적인 추세 및 연직 분포)

  • Yoo Jung-Moon;Jeong Eun-Joo
    • Journal of the Korean earth science society
    • /
    • v.26 no.3
    • /
    • pp.199-217
    • /
    • 2005
  • Using monthly total ozone data obtained from a Total Ozone Mapping Spectrometer (TOMS) onboard the Nimbus-7 and Earth Probe satellite, this study examined the trend in the total amount of global ozone during two periods: from 1979-1992 [Early period] and 1997-2002 [Latter period]. The Annual average of total ozone during the Early period was globally reduced by about 10 DU compared to the amount during the Latter, except in some areas between the equator and 20 N. Global trends of total ozone showed a decrease of -6.30 DU/decade during 1979-1992, and an increase of 0.12 DU/decade during 1997-2002. Its enhancement during the Latter period was especially noticeable in tropical areas. The EOF analyses of total ozone from this period indicated signs of temporal/spatial variability, associated with the phenomena of Quasi-Biennial Oscillation (QBO), Quasi-Triennial Oscillation (QTO), El Nino Southern Oscillation (ENSO), and volcanic eruption. Seasonal profiles of tropospheric ozone in the tropics obtained from ozonesondes, showed the spatial pattern of zonal wavenumber one. Overall, this study may be useful in analyzing possible causes in the variations of statospheric and tropospheric ozone.

Trends and Factors of Ozone Concentration Variations in Korea (우리나라의 오존도 변화 추이와 주요 인자)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.607-623
    • /
    • 2000
  • Major trends of ozone concentration variations in Korea were investigated by using observation data from around 100 stations for the period of 1991∼1997. In addition, important regulating those variations were inferred. Three measures such as the number of days exceeding 80ppb, the 95th percentile of daily maxima, and the annual average concentration were used for the analysis of multi-scale ozone concentration variations. Three areas in the southwest (Sosan, Mokpo, and Cheju) of which monitoring has been operated since 1995 showed the highest annual average concentrations over; this was noted because of the high annual average in the Yosu area in the early 1990s. Large increases in annual average concentrations were observed along the relatively cleaner areas connecting Kangnung and Kwangju(northeast to southwest), in contrast to polluted areas connecting Seoul and Pusan(northeast to southeast). Both the number of exceedance days and the daily maximum concentration were nearly constant in the Greater Seoul Area in spite of interannual flucturations associated with year-to-year changes in air temperature. Within the Greater Seoul Area, all three measures usually showed the same trend; they decreased in the middle and west and increased in the east and northeast. All three measures including the number of exceedance days increased largely at Sillim where the average concentration was high but no exceedance days were recorded in the early 1999s, Nationwide ozone concentration variations appear to be determined by the competitive influence of long-range transport and local urban emissions, Within the city including the Greater Seoul Area, changes in emission which accompany changes in population and in the number if vehicles ( in the process of urban development) were found to be important components of ozone concentration variations.

  • PDF

A Case Study of Characterization of AOC Formation

  • Kim, Ji-Hoon;Hwang, Hyeon-Uk;Kim, Young-Ju
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.261-267
    • /
    • 2010
  • The variation of assimilable organic carbon(AOC) concentration at each condition of ozonation was investigated using a model water and drinking water resource. AOC concentration of model raw water and drinking water resource tended to increase at low ozone dose. The maximum AOC concentration was detected when the residual ozone begin to be measured. Also, the AOC concentration increase at pH 8 compared to both pH 6 and 7 while that for pH 9 decreased rapidly. The removal characteristics of trihalomethane formation potential(THMFP) by ozonation was also investigated. Unlike the trend of AOC, the THMFP concentration never increased by ozonation but decreased even at low ozone dosage. From these results, the ozone dosage would be effective to simultaneously decrease both AOC and THMFP.

Statistical Analysis for Ozone Long-term Trend Stations in Seoul, Korea (통계적 기법을 적용한 서울의 오존 장기변동 대표측정소 선정)

  • Shin, Hyejung;Park, Jihoon;Son, Jungseok;Rho, Soona;Hong, Youdeong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2015
  • This study was conducted for the establishment of statistical method to determine the representative air quality monitoring station representing long-term ozone trends of Seoul. In this study, hourly ozone concentrations from 2002 to 2011 were used for further analysis. KZ-filter, correlation matrix, cluster analysis, and Kriging method were applied to select the representative station. The analysis based on correlation matrix found that long-term trend of ozone concentrations measured at Sinjung, Sadang, and Bun-dong showed a high correlation. The cluster analysis found that the former three stations belonged to the same cluster. The analysis based on Kriging method also showed that the former three stations were highly correlated with other stations in spatial distribution. Considering these results and the highest correlation coefficient of Sinjung station, the Sinjung station was the most suitable as the representative station used to understand the long-term ozone trend of Seoul. This result could be applied to understand long-term trend of other pollutants. Furthermore, this result can also be used to assess the appropriacy of spatial distribution of national air quality monitoring stations.

Spatial-temporal variations in surface ozone concentrations in Busan metropolitan area (부산지역 오존농도의 시·공간 분포 변화)

  • Kang, Yoon-Hee;Kim, Yoo-Keun;Hwang, Mi-Kyeong;Jeong, Ju-Hee;Kim, Hyunsu;Kang, Min-Seong
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.169-182
    • /
    • 2019
  • Temporal and spatial variations in surface ozone concentrations in Busan were investigated by using observation data from urban air quality sites during 2001-2016. The annual ozone concentrations showed a significant increasing trend of $+0.40ppb\;yr^{-1}$ in this period, with a more rapid increase of $+0.81ppb\;yr-1$ since 2010. For the monthly analysis, the increase in ozone concentration was the greatest in August ($+0.68ppb\;yr-1$). These ozone trends were due mainly to rising temperature ($+0.05^{\circ}C\;yr^{-1}$) and weak decreasing precipitation ($-6.42mm\;yr^{-1}$). However, the extreme weather events (heat wave, localized heavy rain, etc.) lead to an increase in short-term variability of ozone since 2010. The relatively low ozone concentrations in the downtown area were caused by high NOx emissions from mobile sources. The increases in ozone concentrations were observed at most of the air quality monitoring sites due to the reductions in anthropogenic emissions of NOx during 2001-2015. However, in the southern coastal area, lower rates of increase in ozone concentrations were observed by $-0.10{\sim}0.25ppb\;yr^{-1}$ due to the significant NOx emitted by ships in the Busan port and Busan new port.

Modeling Extreme Values of Ground-Level Ozone Based on Threshold Methods for Markov Chains

  • Seokhoon Yun
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.2
    • /
    • pp.249-273
    • /
    • 1996
  • This paper reviews and develops several statistical models for extreme values, based on threshold methodology. Extreme values of a time series are modeled in terms of tails which are defined as truncated forms of original variables, and Markov property is imposed on the tails. Tails of the generalized extreme value distribution and a multivariate extreme value distributively, of the tails of the series. These models are then applied to real ozone data series collected in the Chicago area. A major concern is given to detecting any possible trend in the extreme values.

  • PDF