• 제목/요약/키워드: ozone monitoring

검색결과 177건 처리시간 0.021초

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

The Measures of Ozone Pollution: An Analysis of Ozone Concentration Data in USA

  • Kim, Hong-J.;Lovell, Sabrina J.;O'Farrell, John;Cho, Yong-Sung
    • Asian Journal of Atmospheric Environment
    • /
    • 제2권1호
    • /
    • pp.47-53
    • /
    • 2008
  • In this study, we analyzed how ozone pollution could be differently measured and how these different measures varied year to year and across the ten most populated cities in the United States, from 1980 to 2000. Although peak values of ozone concentration have been significantly reduced in most polluted U.S. cities for the last 20 years, the annual average values of ozone concentration have not been lowered as much as peak values. Ozone concentration data for each city shows a unique pattern of distribution, central tendency, and also there is a wide variation among different ozone measures. Two different cities with the same annual mean concentration of ozone can experience very different distributions of ozone concentration within a year. Ozone measures also show a wide margin of variability as they are estimated from different ozone monitoring sites within each city. Ozone pollution statistics can be largely varied depending on the choice of measures, monitoring sites, and averaging time period. EPA's new ozone standard of 0.08 ppm averaged over an eight-hour appears to be more stringent than the current maximum ozone standard of 0.12 ppm averaged over one hour.

CMAQ을 이용한 수도권 풍하지역의 고농도 오존 현상 모사 (A Simulation of High Ozone Episode in Downwind Area of Seoul Metropolitan Using CMAQ Model)

  • 이종범;송은영
    • 환경영향평가
    • /
    • 제15권3호
    • /
    • pp.193-206
    • /
    • 2006
  • Recently, high ozone episode occurred frequently in Korea. Moreover ozone episode occurred not only in the city but also in background area where local anthropogenic sources are not important. It analyzed frequency exceeding 100ppb ozone at air quality monitoring stations in Seoul and rural area during 1995-2004. This paper reports on the use of the Community Multiscale Air Quality (CMAQ) modelling system to predict hourly ozone levels. Domain resolutions of 30km, 10km, 3.333km (innermost) have been employed for this study. Summer periods in June 2004 have been simulated and the predicted results have been compared to data for metropolitan and rural air quality monitoring stations. The model performance has been evaluated with measured data through a range of statistical measures. Although, the CMAQ model reproduces the ozone temporal spatial trends it was not able to simulate the peak magnitudes consistently.

오존 자동측정망 자료 중의 이상치 점검 (Anomaly Test for Ozone Concentration Data from National Air Monitoring Stations)

  • 김영성
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.139-150
    • /
    • 1999
  • The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.

  • PDF

수도권에서 오존생성 기여도 산출에 관한 연구 (Evaluation of Incremental Reactivity and Ozone Production Contribution of VOCs Using the PAMS Data in Seoul Metropolitan Area)

  • 이종현;한진석;윤혜경;조석연
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.286-296
    • /
    • 2007
  • Ozone creation potentials suited for Seoul metropolitan area was derived by utilizing the PAMS monitoring data and the source inventory. A simple box model with variable height was developed to calculate the incremental reactivity for all the ozone episode days in the year 2003 and 2004. RIR (Relative Incremental Reactivity) was introduced as a measure of contribution to ozone generation in the Seoul metropolitan area. RIR was defined as a function of ratio of VOC to $NO_x$ and therefore it addresses both VOC and $NO_x$ limited regime. For the days that more than 10 monitoring stations out of 27 monitoring station in Seoul recorded the daily maximum ozone concentrations higher than 70 ppb, toluene had the highest RIR value in all the type II and type III PAMS site and m/p-xylene followed with the second highest RIR value. Analyses using MIR (Maximum Incremental Reactivity) and POCP (Photochemical Ozone Creation Potential) instead of RIR also yields dominance of toluene and m/p-xylene in generating ozone concentrations to demonstrate the validity of RIR.

고농도 오존발생시 취약계층 노출 인구 현황 및 변화 (Estimation and Variation of an Exposed Population of a Vulnerable Group to High Ozone Episodes)

  • 강재은;방진희;오인보;김유근
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.697-705
    • /
    • 2014
  • The exposed population of a vulnerable group to high ozone episodes (exceeding 60 ppb/8h) was estimated in Busan metropolitan city from 2000 to 2010. The frequency of high ozone days at monitoring sites and the number of the population aged over 65 were used to calculate the accumulated (total, seasonal, and yearly) number of the exposed older population (EOP) to high ozone episodes during the study period based on administrative areas, by interpolation and zonal mean methods in ArcGIS software. The older population in this city had increased significantly from 2000 to 2010 (representing over 10% of the total population in 2010). The vulnerable areas (e.g. the eastern area of the city) of the EOP to high ozone episodes were different from the areas with frequent high ozone episodes (e.g., the western area) due to the increase of the older population in particular areas. The difference was more significant in spring than in any other season, and in 2010 than in previous years (2000 and 2005).

오존발생기의 특성 연구 및 모니터링 시스템 구축 (A Study on the Characteristics of Ozonizers and Implementation of a Monitoring System)

  • 김용철;김규식;최주엽
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.460-466
    • /
    • 2001
  • 오존의 산화력은 상용의 산화제중에서 가장 강력하고 따라서 수처리에서 염소를 대체해 가고 있다. 또한, 수처리 시 효율적인 에너지절감을 위해서도 고농도의 오존이 요구되고 무성방전 오존발생기가 산업체에서 효과적이고 가장 널리 사용된다. 본 연구에서 오존방전전압, 주파수, 오존방전관 내의 온도 등이 오존발생율을 결정짓는 주요한 변수임을 확인하였다. 이들 변수들을 효과적으로 제어하기 위해 그래픽사용자 인터페이스를 갖는 모니터링 시스템을 구축하였다. 이 시스템은 윈도우 98에서 C++과 LabView로 프로그램 하였다.

  • PDF

GMAP 2021 캠페인 기간 용인지역 오존 연직 분포 관측 (The Observation of Ozone Vertical Profile in Yongin, Korea During the GMAP 2021 Field Campaign)

  • 류호선;구자호;김형규;이나현;이원진;김주완
    • 대기
    • /
    • 제32권3호
    • /
    • pp.247-261
    • /
    • 2022
  • The importance of ozone monitoring has been growing due to the polar ozone depletion and increasing tropospheric ozone concentration over many Asian countries, including South Korea. In-situ measurement of the vertical ozone structure has advantages for ozone research, but observations are not sufficient. In this study, ozonesonde measurements were performed from October to November in Yongin during the GMAP (The GEMS Map of Air Pollution) 2021 campaign. The procedure for ozonesonde preparation and initial analysis of the observed ozone profile are documented. The observed ozone concentrations are in good agreement with previous studies in the troposphere, and they capture the stratospheric ozone distribution as well, including stratosphere-troposphere exchange event. These balloon-borne in situ measurements can contribute to the evaluation of remote sensing measurements such as Geostationary Environment Monitoring Spectrometer (GEMS). This document focuses on providing essential information of ozonesonde preparation and measurement for domestic researchers.