• Title/Summary/Keyword: ozone monitoring

Search Result 177, Processing Time 0.027 seconds

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

불포화 토양내에서 가스상 오존 측정을 위한 광섬유센서의 적용

  • 정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.111-114
    • /
    • 2003
  • A new monitoring system has been developed for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone was obtained by converting the normalized intensity into ozone concentration. The FOTDP system reflected the ideal transport phenomena of gas phase ozone at various flow rates. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of SOM. However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

  • PDF

The Measures of Ozone Pollution: An Analysis of Ozone Concentration Data in USA

  • Kim, Hong-J.;Lovell, Sabrina J.;O'Farrell, John;Cho, Yong-Sung
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • In this study, we analyzed how ozone pollution could be differently measured and how these different measures varied year to year and across the ten most populated cities in the United States, from 1980 to 2000. Although peak values of ozone concentration have been significantly reduced in most polluted U.S. cities for the last 20 years, the annual average values of ozone concentration have not been lowered as much as peak values. Ozone concentration data for each city shows a unique pattern of distribution, central tendency, and also there is a wide variation among different ozone measures. Two different cities with the same annual mean concentration of ozone can experience very different distributions of ozone concentration within a year. Ozone measures also show a wide margin of variability as they are estimated from different ozone monitoring sites within each city. Ozone pollution statistics can be largely varied depending on the choice of measures, monitoring sites, and averaging time period. EPA's new ozone standard of 0.08 ppm averaged over an eight-hour appears to be more stringent than the current maximum ozone standard of 0.12 ppm averaged over one hour.

A Simulation of High Ozone Episode in Downwind Area of Seoul Metropolitan Using CMAQ Model (CMAQ을 이용한 수도권 풍하지역의 고농도 오존 현상 모사)

  • Lee, Chong Bum;Song, Eun Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.3
    • /
    • pp.193-206
    • /
    • 2006
  • Recently, high ozone episode occurred frequently in Korea. Moreover ozone episode occurred not only in the city but also in background area where local anthropogenic sources are not important. It analyzed frequency exceeding 100ppb ozone at air quality monitoring stations in Seoul and rural area during 1995-2004. This paper reports on the use of the Community Multiscale Air Quality (CMAQ) modelling system to predict hourly ozone levels. Domain resolutions of 30km, 10km, 3.333km (innermost) have been employed for this study. Summer periods in June 2004 have been simulated and the predicted results have been compared to data for metropolitan and rural air quality monitoring stations. The model performance has been evaluated with measured data through a range of statistical measures. Although, the CMAQ model reproduces the ozone temporal spatial trends it was not able to simulate the peak magnitudes consistently.

Anomaly Test for Ozone Concentration Data from National Air Monitoring Stations (오존 자동측정망 자료 중의 이상치 점검)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.139-150
    • /
    • 1999
  • The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.

  • PDF

Evaluation of Incremental Reactivity and Ozone Production Contribution of VOCs Using the PAMS Data in Seoul Metropolitan Area (수도권에서 오존생성 기여도 산출에 관한 연구)

  • Lee, J.H.;Han, J.S.;Yun, H.K.;Cho, S.Y.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.286-296
    • /
    • 2007
  • Ozone creation potentials suited for Seoul metropolitan area was derived by utilizing the PAMS monitoring data and the source inventory. A simple box model with variable height was developed to calculate the incremental reactivity for all the ozone episode days in the year 2003 and 2004. RIR (Relative Incremental Reactivity) was introduced as a measure of contribution to ozone generation in the Seoul metropolitan area. RIR was defined as a function of ratio of VOC to $NO_x$ and therefore it addresses both VOC and $NO_x$ limited regime. For the days that more than 10 monitoring stations out of 27 monitoring station in Seoul recorded the daily maximum ozone concentrations higher than 70 ppb, toluene had the highest RIR value in all the type II and type III PAMS site and m/p-xylene followed with the second highest RIR value. Analyses using MIR (Maximum Incremental Reactivity) and POCP (Photochemical Ozone Creation Potential) instead of RIR also yields dominance of toluene and m/p-xylene in generating ozone concentrations to demonstrate the validity of RIR.

Estimation and Variation of an Exposed Population of a Vulnerable Group to High Ozone Episodes (고농도 오존발생시 취약계층 노출 인구 현황 및 변화)

  • Kang, Jae-Eun;Bang, Jin-Hee;Oh, In-Bo;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.697-705
    • /
    • 2014
  • The exposed population of a vulnerable group to high ozone episodes (exceeding 60 ppb/8h) was estimated in Busan metropolitan city from 2000 to 2010. The frequency of high ozone days at monitoring sites and the number of the population aged over 65 were used to calculate the accumulated (total, seasonal, and yearly) number of the exposed older population (EOP) to high ozone episodes during the study period based on administrative areas, by interpolation and zonal mean methods in ArcGIS software. The older population in this city had increased significantly from 2000 to 2010 (representing over 10% of the total population in 2010). The vulnerable areas (e.g. the eastern area of the city) of the EOP to high ozone episodes were different from the areas with frequent high ozone episodes (e.g., the western area) due to the increase of the older population in particular areas. The difference was more significant in spring than in any other season, and in 2010 than in previous years (2000 and 2005).

A Study on the Characteristics of Ozonizers and Implementation of a Monitoring System (오존발생기의 특성 연구 및 모니터링 시스템 구축)

  • 김용철;김규식;최주엽
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.460-466
    • /
    • 2001
  • The oxidizing power of ozone is the greatest of all commercially available oxidizers and thus ozone is taking the place of chlorine for water treatment. For energy-effective treatment of water, ozone should be generated in high concentration. A silent glow discharge ozonizer is high effective in industrial aspect and thus is the most widely used. We found that the key parameters associated with the ozone generation rate are the driving voltage of the discharger, the discharge rate and the temperature of the ozone generation tube. For an easy control of these parameters, we build a monitoring system with graphical user interface. This system is based on Windows-98 PC, programmed with C++ and LabView.

  • PDF

The Observation of Ozone Vertical Profile in Yongin, Korea During the GMAP 2021 Field Campaign (GMAP 2021 캠페인 기간 용인지역 오존 연직 분포 관측)

  • Ryu, Hosun;Koo, Ja-Ho;Kim, Hyeong-Gyu;Lee, Nahyun;Lee, Won-Jin;Kim, Joowan
    • Atmosphere
    • /
    • v.32 no.3
    • /
    • pp.247-261
    • /
    • 2022
  • The importance of ozone monitoring has been growing due to the polar ozone depletion and increasing tropospheric ozone concentration over many Asian countries, including South Korea. In-situ measurement of the vertical ozone structure has advantages for ozone research, but observations are not sufficient. In this study, ozonesonde measurements were performed from October to November in Yongin during the GMAP (The GEMS Map of Air Pollution) 2021 campaign. The procedure for ozonesonde preparation and initial analysis of the observed ozone profile are documented. The observed ozone concentrations are in good agreement with previous studies in the troposphere, and they capture the stratospheric ozone distribution as well, including stratosphere-troposphere exchange event. These balloon-borne in situ measurements can contribute to the evaluation of remote sensing measurements such as Geostationary Environment Monitoring Spectrometer (GEMS). This document focuses on providing essential information of ozonesonde preparation and measurement for domestic researchers.