• 제목/요약/키워드: ozone free

검색결과 74건 처리시간 0.027초

실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측 (Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments)

  • 조민;정현미;김이호;손진식;박상정;윤제용
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성 (Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure)

  • 박용화;이광희;장암
    • 대한환경공학회지
    • /
    • 제39권10호
    • /
    • pp.549-555
    • /
    • 2017
  • 본 연구는 오존용해탱크 구조에 따라 마이크로오존버블의 분포, 에너지 소비, 수처리 효율이 어떻게 변하는지를 알아보고자 하였다. 오존용해탱크 내부의 격판은 압력의 변화, 전단력, 선회유동을 발생시키고 이는 버블 직경의 크기에 변화를 준다. 버블 직경의 크기는 내부의 격판에 따라 10.5%까지 차이가 났다. 오존 버블 직경의 변화는 에너지 소비와 관련이 깊다. 오존 버블이 작아질수록 버블생성에너지는 높아지지만 용존 효율이 올라가면서 오존생산에너지는 줄어들게 된다. 따라서 버블생성에너지와 오존생산에너지의 합이 최소인 마이크로오존버블을 생성하는 오존용해탱크를 선정하여야 한다. 동일한 양의 오존가스을 방류수에 주입하기 위해 소비된 에너지는 내부의 격판에 따라 2.5%까지 차이가 났다. 하지만 수처리 효율까지 고려한다면 오존용해탱크 선정 조건이 달라진다. 오존 버블이 작아질수록 증가하는 자유라디칼이 수처리에 매우 효율적이기 때문이다. 동일한 오존주입농도에서도 내부의 격판에 따라 수처리 효율이 10.4%까지 차이가 났다. 따라서 수처리 효율과 에너지 효율을 고려하여 합리적인 마이크로오존버블을 생성하는 오존용해탱크 구조에 대하여 연구하였다.

고분자 전해질을 이용한 전기분해식 오존 발생에 관한 연구 (Study of Electrolysis Ozone Generator Using Polymer Electrolyte)

  • 박종은;이주봉;이홍기;박수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.906-908
    • /
    • 1999
  • The application of ozone solid polymer electrolyte or Membrel water electrolysis cells with $PbO_2$ anodes for anodic generation of ozone in electrolyte-free water is reported. Maximum yields were obtained at a temperature of $25^{\circ}C-30^{\circ}C$ and current density of about 1A/$cm^2$. The current efficiency was not found to depend on ozone concentration in the feed water. exclusive transference of electric current by protons absence of convection in the electrolyte and high oxygen oversaturatation in the vicinity of electrode

  • PDF

오존 접촉 반응기의 용존 오존 농도 및 페놀 분해에 미치는 운전변수의 영향 (Effects of Operating Parameters on Dissolved Ozone and Phenol Degradation in Ozone Contact Reactor)

  • 정재우;박정욱;이춘식
    • 대한환경공학회지
    • /
    • 제32권3호
    • /
    • pp.241-247
    • /
    • 2010
  • 오존 접촉 반응기에서 용존 오존 농도 및 페놀 제거에 미치는 운전변수의 영향에 대해 실험실 규모 실험을 수행하였다. 반응기로 가스상 오존이 공급되고 일정한 시간이 경과한 후에 용존 오존 농도는 포화 농도에 도달하였으며 포화 농도의 크기는 운전 변수에 의해 영향을 받는 것으로 나타났다. 수용액내의 오존은 높은 pH 조건에서 불안정하므로 용존 오존 농도는 용액의 초기 pH값이 증가함에 따라 감소하였다. 일정한 유량의 기체가 반응기로 공급되는 조건에서 가스상 오존 농도의 크기는 용존 오존의 포화농도에 중요한 영향을 미치며 일정한 농도의 가스상 오존이 공급될 때 가스 유량은 용존 오존이 포화되는 속도에 영향을 주는 것으로 관찰되었다. 페놀 제거에 미치는 운전변수의 영향은 각 운전변수가 용존 오존 농도에 미치는 영향과 밀접하게 관련되어 있는 것으로 나타났다. 용존 오존은 높은 pH 조건에서 빠르게 분해되어 페놀과의 반응성이 높은 자유라디칼을 생성시키므로 pH가 증가함에 따라 페놀 제거가 향상되었다. 동일한 pH 조건에서 가스상 오존 농도 및 가스 공급량의 증가는 용존 오존을 증가시킴으로써 페놀 분해를 증진시키는 것으로 나타났다. 메탄올의 주입은 OH 라디칼을 소비시켜 페놀 분해를 방해하는 것으로 관찰되었다.

오존처리를 이용한 기체분리막의 성능 향상에 관한 연구 (A Study on the Enhancement of the Performance of Gas Separation Membranes by Ozone Treatment)

  • 류동현;최승학;오세중;구자경
    • 멤브레인
    • /
    • 제10권4호
    • /
    • pp.192-197
    • /
    • 2000
  • 상용 고분자막으로 많이 사용되는 Polysulfone(PSF)을 오존으로 처리하여 기체의 투과 및 분리특성을 조사하였다. 고분자막의 오존처리는 chamber 내부에 막을 설치하고 약 5vol.%의 오존을 포함한 산소를 chamber에 연속적으로 공급하면서 일정시간 동안 오전처리를 수행하였다. PSF막의 선택도는 오존처리시간에 따라 증가하였으며 적정 오존처리 시간은 1.5시간이면 충분한 것으로 조사되었다. 그리고, 오존처리에 의한 He/$N_2$, $H_2$/$N_2$, $O_2$/$N_2$, $CO_2$/$CH_4$등의 선택도의 증가는 분자크기가 큰 $N_2$$CH_4$의 투과도의 감소에 기인하며 분자크기가 작은 기체의 투과도의 감소는 매우 작은 것으로 나타났다. 오존처리에 의한 선택도의 증가는 오존이 PSF 고분자를 부분적으로 산화시키고 이때 생성된 산소복합체들이 PSF의 자유부피를 감소시키기 때문으로 생각된다.

  • PDF

Effects of ozone, ultraviolet and an organic acid-based disinfectant against porcine reproductive and respiratory syndrome virus

  • Yoon, Yong-Dae;Kim, Won-Il
    • 한국동물위생학회지
    • /
    • 제36권3호
    • /
    • pp.157-162
    • /
    • 2013
  • A good level of biosecurity practice is important for efficient porcine reproductive and respiratory syndrome (PRRS) control. In the current study, disinfecting ability of ozone against PRRS virus (PRRSV) was evaluated in comparison with ultraviolet (UV) and an organic acid-based disinfectant to assess the possible use of ozone for disinfecting farm vehicles, equipments, and materials to reduce the risk of new virus introduction. For in vitro evaluation, the levels of infectious virus and viral RNA were determined on the swabs collected from the floor surface of each room treated with either ozone, UV or the disinfectant up to 30 min after contamination with 100 mL of VR2332 ($10^5\;TCID_{50}/mL$). For in vivo evaluation, 3, 4-week old, PRRS-free pigs were housed into those rooms right after the last swab collection. Then the pigs in each room were injected intramuscularly with the corresponding swab samples collected at the last time point and pooled per each room. Although ozone, UV, and the disinfectant significantly reduced the levels of PRRSV RNA contamination, ozone was most effective in removing the viral RNA. In addition, the virus collected after at least 10 min exposure to ozone failed to replicate in pigs while the virus collected after treatment with UV and the disinfectant for 30 min still replicated in pigs. Based on the results, it was concluded that ozone is more effective in inactivating PRRSV as compared with UV and the organic acid-based disinfectant.

Pt/Ti 격자형 평판 전극을 이용한 혼합 산화제 생성 및 E. coli 불활성화 (Formation of Mixed Oxidants and Inactivation of E. coil by the Electrochemical Process using a Grid Shape Pt/Ti Electrode)

  • 정연정;오병수;박상연;백고운;강준원
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.851-855
    • /
    • 2006
  • The aim of this study was to investigate characteristics of formation of mixed oxidants and some aspects of the performance of electrochemical process as an alternative disinfection strategy for water purification. The study of electrochemical process has shown free chlorine to be produced, but smaller amounts of stronger oxidants, such as ozone, hydrogen peroxide and OH radicals, were also generated. The formation of ozone and hydrogen peroxide increased with increasing electric conductivity, but was limited at conductivities greater than 0.6 mS/cm. Also, formation of OH radical was enhanced as electric conductivity was increased to 0.9 mS/cm and The stead-state concentrations of OH radical were calculated at $1.1{\sim}6.4{\times}10^{-14}M$. Using E. coti, inactivation kinetic studies were performed. With the exception of free chlorine, the role of mixed oxidants, especially OH radical, was investigated for enhancement of the inactivation rate.

Interactive Effects of Ozone and Light Intensity on Platanus occidentalis L. Seedlings

  • Kim, Du-Hyun;Han, Sim-Hee;Lee, Kab-Yeon;Kim, Pan-Gi
    • 한국산림과학회지
    • /
    • 제97권5호
    • /
    • pp.508-515
    • /
    • 2008
  • Sycamore (Platanus occidentalis L.) seedlings were grown under low light intensity and ozone treatments to investigate the role of the light environment in their response to chronic ozone stress. One-year-old seedlings of Platanus occidentalis L. were grown in pots for 3 weeks under low light (OL, $150{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) and high light (OH, $300{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) irradiance in combination with 150 ppb of ozone fumigation. After three weeks of ozone and light treatment, seedlings were placed in ozone free clean chamber for 3 weeks for recovery from ozone stress with same light conditions to compare recovery capacity. Ozone fumigation determined an impairment of the photosynthetic process. Reduction of leaf dry weight (14%) and shoo/root ratio (17%) were observed in OH treatment. OL treatment also showed severe reductions in leaf dry weight and shoot/root ratio by 48% and 36% comparing to control, respectively. At the recovery phase, OH-treated plants recovered their biomass, whereas OL-treated plant showed reduction in leaf dry weight (52%) and shoot/root ratio (49%). OH-treated plants reached similar relative growth rate (RGR) comparing to control, whereas OL-treated plants showed lower RGR in stem height. However, there were no significant differences in response to those treatments in stem diameter RGR at the recovery phase. Ozone treatment produced significant reduction of net photosynthesis in both high and low light treatments. Carboxylation efficiency and apparent quantum yield in OL-treated plants showed significant reductions rate to 10% and 45%, respectively. At the recovery stage, ozone exposed seedlings under high light had similar photosynthetic capacity comparing to control plants. Antioxidant enzymes activities such as superoxide dismutase (SOD), ascorbate peroxidase (APX), and glutathione reductase (GR) were increased in ozone fumigated plants only under low light. The present work shows that the physiological changes occur in photosynthesis-related parameters and growth due to ozone and low light stress. Thus, low light seems to enhance the detrimental effects of ozone on growth, photosynthesis, and antioxidant enzyme responses.

지표 자외선 복사 변화에 미치는 오존 전량, 구름 및 적설 효과 (Effects of Ozone, Cloud and Snow on Surface UV Irradiance)

  • 이윤곤;김준;이방용;조희구
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.439-451
    • /
    • 2004
  • Total solar irradiance (750), total UV irradiunce (TUV) and erythemal UV irradiance (EUV) measured at King Sejong station $(62.22^{\circ}S,\;58.78^{\circ}W)$ in west Antarctica have been used together with total ozone, cloud amount and snow cover to examine the effects of ozone, cloud and snow surface on these surface solar inadiunce over the period of 1998-2003. The data of three solar components for each scan were grouped by cloud amount, n in oktas $(0{\leq}n<3,\;3{\leq}n<4,\;4{\leq}n<5,\;5{\leq}n<6,\;6{\leq}n<7\;and\;7{\leq}n<8)$ and plotted against solar zenith angle (SZA) over the range of $45^{\circ}\;to\;75^{\circ}$. The radiation amplification factor (RAE) is used to quantify ozone effect on EUV. RAF of EUV decreases from 1.51 to 0.94 under clear skies but increases from 0.94 to 1.85 under cloudy skies as SZA increases, and decreases from 1.51 to 1.01 as cloud amount increases. The effects of cloud amount and snow surface on EUV are estimated as a function of SZA and cloud amount after normalization of the data to the reference total ozone of 300 DU. In order to analyse the transmission of solar radiation by cloud, regression analyses have been performed for the maximum values of solar irradiance on clear sky conditions $(0{\leq}n<3)$ and the mean values on cloudy conditions, respectively. The maximum regression values for the clear sky cases were taken to represent minimum aerosol conditions fur the site and thus appropriate for use as a normalization (reference) factor for the other regressions. The overall features for the transmission of the three solar components show a relatively high values around SZAs of $55^{\circ}\;and\;60^{\circ}$ under all sky conditions and cloud amounts $4{\leq}n<5$ and $5{\leq}n<6$. The transmission is, in general, the largest in TUV and the smallest in EUV among the three components of the solar irradiance. If the ground is covered with snow on partly cloudy days $(6{\leq}n<7)$, EUV increases by 20 to 26% compared to snow-free surface around SZA $60^{\circ}-65^{\circ}$, due to multiple reflections and scattering between the surface and the clouds. The relative difference between snow surface and snow-free surface slowly increases from 9% to 20% as total ozone increases from 100 DU to 400 DU under partly cloud conditions $(3{\leq}n<6)$ at SZA $60^{\circ}$. The snow effects on TUV and TSO are relatively high with 32% and 34%, respectively, under clear sky conditions, while the effects changes to 36% and 20% for TUV and TSO, respectively, as cloud amount increases.

The Role of Fronts on the Vertical Transport of Atmospheric Pollutants (2-D model)

  • Nam, Jae-Cheol
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.65-68
    • /
    • 2003
  • A quantitative study of the amount of air transported between the boundary layer and the free atmosphere is important for understanding air quality and upper tropospheric ozone, which is a greenhouse gas. Frontal systems are known to be an effective mechanism for the vertical transport of pollutants. Numerical experiments have been performed with a simple two-dimensional front model to simulate vertical transport of trace gases within developing cold fronts. Three different trace gases experiments have been done numerically according to the different initial fields of trace gases such as aerosol, ozone and $H_2O_2$. Trace gas field tilts to the east while the front tilts to the west. Aerosol simulation shows that pollutants can be transported out of the boundary to altitudes of about 10 km. The stratospheric ozone is brought downwards in a tropopause fold behind of the frontal surface. The meridional gradient in trace gas ($H_2O_2$) can cause a complicate structure in the trace field by the meridional advection.

  • PDF